Records from 2016 to 2026. Most recent: inspection, 1 June 2026.
Inspection history · 18
1 June 2026
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8385603
4 February 2025
ISPS Exam · Ballast Water Examination · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8074799
21 March 2024
Administrative Inspection · COC-MODU Renew
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7934877
1 March 2023
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7647848
28 December 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7629350
31 March 2022
COC-MODU Annual · Ballast Water Examination · ISPS Exam
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7422844
9 March 2021
ISPS Exam · Ballast Water Examination · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7159178
2 June 2020
COC-MODU Annual · ISPS Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6971773
15 March 2019
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6643374
1 July 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6469755
4 June 2018
COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6434037
11 March 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6398502
12 June 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6172893
28 May 2017
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6158068
21 March 2017
Deficiency Check · COC-MODU Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6109162
8 September 2016
VRP Review · Administrative Inspection · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6001910
8 July 2016
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5934087
6 April 2016
COC-MODU Annual
Type not classified · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5850156
Electrical › Electrical Distribution System (service) › Cable
Issued 18 May 2017
Resolved
Cables and wiring should be installed and supported in such a manner as to avoid chafing or other damage. A verticle wire run in shaker house was found to be loose and unsecured from the deck to overhead. 09 MODU / 5.6.11
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 May 2017
Resolution: Def was corrected prior to departure of Marine Inspectors. Corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 May 2017
Resolved
The minimum fire integrity of decks should be as prescribed in Table 9-2. A multi cable transit was found improperly installed in shaker house jepordizing the fire integrity of the penetration. 09 MODU / 9.2.4
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 30 May 2017
Resolution: Recieved statement and pics that def has been rectified.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 May 2017
Resolved
A wind direction indicator should be located on the unit that indicates wind conditions over TLOF. Wind indicator on the unit in vicinity of TLOF is faded and not indicating proper wind direction. 09 MODU / 13.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 22 May 2017
Resolution: Captain provided email stating that wind indicator at helo deck had been replaced.
Documentation › Certificates/Documents › MODU Safety Certificate
Issued 18 May 2017
Resolved
Any exemptions granted under 1.4 should be clearly noted on the certificate. MODU Safety Cert does not properly reflect all exemptions. 09 MODU / 1.6.8
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 21 May 2017
Resolution: vessel master provided explanation from flag that the exemptions were on other SOLAS documents.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 May 2017
Resolved
Crew members with enclosed space entry or rescue responsibiities should participate in an enclosed space entry and rescue drill to be hled on board the unit at least once every two months. Crew members with enclosed space entry or rescue responsibilities are not conducting drills in accordance with the code. 09 MODU / 14.14
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 21 May 2017
Resolution: REcieved email from [name withheld] stating that all crewmember with assigned duties participated in drill in accordance with the code.
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 18 May 2017
Resolved
The survey of Marine Diesel engines and equipment for compliance with regulation 13 of this annex shall be conducted in accordance with the revised NoX technical code. Marpol Annex VI reg 5.3.2 / NoX Tech Code 6.2.2.8
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 21 May 2017
Resolution: Captain provided email with entries.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 21 March 2017
Resolved
Vessel was issued COC without exam with a Code 34 C issued due to the fact vessel was warm stacked and minimally manned and at anchor.
Action required: 66 - Prior to drilling or production operations
Resolved 18 May 2017
Resolution: Vessel underwent successful exam on said date.