Records from 2016 to 2026. Most recent: inspection, 10 January 2026.
Inspection history · 56
10 January 2026
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8289270
15 August 2024
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7974937
13 September 2023
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7774393
17 June 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7717373
12 June 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7712888
12 May 2023
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7685217
20 February 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7639120
14 February 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7636450
9 July 2022
PSC B · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7500990
1 May 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7441419
21 April 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7435413
15 April 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7431657
21 February 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7399458
19 February 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7398758
28 October 2021
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7341132
28 October 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7351212
1 October 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7324869
13 June 2021
PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7215242
13 June 2021
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7241767
13 October 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7076443
10 June 2020
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6968787
15 December 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6873998
7 November 2019
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6851420
15 April 2019
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6662398
21 February 2019
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6628742
19 June 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6449538
5 March 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6365225
19 February 2018
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6489275
16 February 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6356029
31 January 2018
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6489065
24 January 2018
Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6340982
7 January 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333796
20 December 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6327222
30 November 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6315325
19 August 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6245357
29 July 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6224376
14 July 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6209018
13 May 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6145351
24 April 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6131238
12 April 2017
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6123269
31 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6115197
14 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6104752
24 February 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6093931
10 February 2017
COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6081284
6 February 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6083282
20 January 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6074185
2 January 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6064612
14 November 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6040888
30 October 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6031852
11 October 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6021268
1 October 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6013709
28 September 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6011234
15 September 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6001543
24 July 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5950885
5 July 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5930689
4 February 2016
COC-GAS Renew · ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5809683
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 21 February 2019
Resolved
Gas Detection equipment should be so designed that it may readily be tested.
During test of fixed gas detection, panel read as high as 99% of LEL while being provided span gas at 35% LEL propane. PSCO witnessed crew recalibrate the system. Second test was found satisfactory.
74SOLAS(14)VII/13.1
1993 IGC 13.6.6
Action required: 10 - Deficiency Rectified
Due 21 February 2019
Resolved 21 February 2019
Resolution: Rectified in presecence of CG examiners
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 4 February 2016
Resolved
Emergency shutdown valves in liquid vlaves should close within 30 sec of activation. The port side manifold liquid emergency valves shut within 45 seconds.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2016
Resolved 5 February 2016
Resolution: Received satisfctory class report.
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 4 February 2016
Resolved
Information shoulb be onboard for safe carriage of cargo including a full physical and chemical description of each cargo. The vessel does not have information on Vinyl Chloride, but it is listed on the COF. The vessel has information on Dimethyl Ether, but is not listed on the COF.
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 11 February 2016
Resolution: Received satisfactory class report.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 4 February 2016
Resolved
The company should establish procedures for key shipboard operations for the sasfety of the personnel and ship. The electrician and cargo engineer reported the gas detection system is periodically tested with cargo samples. The vessel has no procedure to test with cargo samples, only with span gas. To satisfaction of class and coast guard. 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 11 February 2016
Resolution: Recieved satisfactory class report.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 4 February 2016
Resolved
The compnay should ensure all personnel involved have an adequate understanding of releveant rules, regulations, codes and guidelines. Based on the above four deficiencies, an external audit is recommended by the RSO and RO. To satisfaction of class and coast guard. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2016
Resolved 11 February 2016
Resolution: Recieved satisfactory shipboard audit report from class.