SPIRIT OF SEATREK is a 2015 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in March 2025, along with 9 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 21 March 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it35873 - Convention (Subpart B), Gross Ton 21223 - Convention (Subpart B), Net Ton 35873 - Simplified, Gross Ton 63132 - Dead Weight, Metric Ton 21223 - Simplified, Net Ton 74950 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
21 March 2025PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8093297
10 September 2019Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6808600
5 August 2019PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6759614
12 April 2018Deficiency Check · Administrative Inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 March 2025Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed temporary repair to fuel oil return lines on cylinders #1 and #5. Request clarification from certificare issuing authority on acceptance of repairs. 74 SOLAS (AM) I/11(b) 60 ac
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 March 2025
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2025Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed custom fabricated cover to prevent excessive build-up of fumes from seperator box. Request clarification from certificare issuing authority on acceptance of the installation. 74 SOLAS (AM) I/11(b) 60 ac.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 March 2025
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 March 2025Resolved
The purpose of this regulation is to contain a fire in the space of origin... The fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed penetration at A-class fire boundary door between steering gear room and engine room. 74 SOLAS (AM) II-2/9.1.3 60 ac.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 March 2025
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 21 March 2025No resolution recorded
The company should ensure that: inspections are held at appropriate intervals. Conduct inspections and maintenance as per ship specific PMS. PSCO observed several M/E items passed overhaul interval requirements outlined in the maintenance manual and no requests of postponement of routine looks submitted. An internal audit report satisfactory to the OCMI must be submitted wihtin 90 days. 74 SOLAS (AM) IX/3 ISM Code 10.2.1 ac.
Action required: 705 - Other - as specified
Due 13 June 2025 — due date passed with no resolution recorded
THE MEANS FOR SECURING AND MAINTAINING WEATHERTIGHTNESS SHALL BE TO THE SATISFACTION OF THE ADMINISTRATION. QUICK ACTING CLEATS ON THE #1 CARGO HOLD ARE SEIZED AND UNABLE TO BE PROPERLY USED TO ENSURE THE WEATHERTIGHT INTEGREITY OF THE HOLD. ICLL 16.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 10 September 2019
Resolution: Received, reviewed, and accepted class report from NKK stating deficiency was rectified. It was confirmed the seized cleats were freed and lubricated.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 2 March 2018Resolved
Fire-fighter's outfits shall comply with the Fire Safety Systems Code. A fire fighter's outfit protective clothing shall be of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. Fire fighter's outfits onboard do not adequately protect peronnsel faces, neck and jawline. 74 SOLAS (14) II-2/10.1.1; FSS Code 3.2.1.1.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 12 April 2018
Resolution: New Hood and Helmet were purchased by Company and approved by Class NK.
Construction/Loadline › Structures › Door
Issued 2 March 2018Resolved
Fire doors in main vertical zone bulkheads, galley boundaries, and stairway enclosures ther than power-operated watertight doors and those which are normally locked shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. The B deck fire door in main stairway enclosure is not self closing. 74 SOLAS (14) II-2/9.4.1.1.5.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 2 March 2018
Resolution: Fire door latch was repaired during examination.
Operations/Management › Drills/Instruction › Fire
Issued 2 March 2018Resolved
Drills shall, as far as practicable, be conducted as if there were an actual emergency. Crew showed a lack of competency of shipboard fire fighting procedures such as failing to secure power and ventilation before the fire team accessed the space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 2 March 2018
Resolution: Fire drill was reconducted in the emergency generator room.
Means shall be provided whereby normal operation of propulsion can be sustained or restored even though one on the essential auxiliaries becomes inoperative. The No. 5 unit of the main engine's hydraulic accumulator is damaged reducing the output of the main engine to 45% of the maximum output.
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 15 January 2017
Resolution: Received, reviewed and accepted class report from NKK satisfying outstanding requirements related to the restriction. See Documentation for further information.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.