Records from 2016 to 2025. Most recent: inspection, 28 July 2025.
Inspection history · 23
28 July 2025
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8196402
10 March 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8091586
7 September 2024
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 7998605
12 August 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7988705
31 July 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7754809
13 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7651260
21 October 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7584902
3 October 2022
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7636455
14 December 2021
Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7368176
8 December 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7364411
22 February 2021
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7143954
3 August 2020
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7017160
29 April 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6945528
9 December 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6869897
25 March 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6647197
5 March 2019
Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6636659
2 June 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6613951
24 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6422624
9 April 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6388033
28 June 2017
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6232951
31 March 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6114927
21 February 2017
Annual Inspection · Drydock Exam · Internal Structural Exam · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6091659
22 February 2016
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5819504
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 July 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. 46 CFR 182.100
Inspector observed Bilge pump activation float switch on forward bilge pump did not activate pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 5 August 2025
Resolution: Bilge pump automatic activation wiring corrected for proper operation
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 July 2025
Resolved
A hatch exposed to the weather must be watertight. 46CFR 179.360
Inspector observed Focsle hatch was allowing the accumulation of water in the forward void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 5 August 2025
Resolution: Resealed Exterior of hatch base, water tested satisfactory
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 July 2025
Resolved
Equipment grounding conductors must be sized in accordance with section 250-96 of NFPA 70 or other standards specified by the Commandant. 46CFR 179.360
Bonding cable on steering rudder post was terminated with a cut exposing bare wire and no connector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 5 August 2025
Resolution: Attached bonding cable to appropriate location
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 July 2025
Resolved
A vessel must either carry a first aid kit that meets requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. 46CFR 184.710
Inspector identified that first aid kit had several expired contents and therefore did not meet equivalent standards for contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 11 August 2025
Resolution: Observed CG approved First aid kit
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. 46CFR 185.516(a)
Inspector observed donning procedures for only 01 of 02 lifejacket styles onboard vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 18 August 2025
Resolution: Operator opted to only maintain 1 type of Life jacket negating the need to have multiple donning instruction placards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits...Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. 46CFR 185.604(f)
Inspector did not find identification to clearly state the number of total life jackets available in each storage area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 5 August 2025
Resolution: labeled contents of life jacket stowage locations
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 July 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. 46 CFR 184.502
Vessel master was unable to produce an FCC radio operator permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 19 August 2025
Resolution: Operator enrolled in Radio operator course
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 July 2023
Resolved
...the shut off valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Port fuel tank shut off valve disconnected and rendered inoperable at time of inspection. Replace port fuel shut off cable. 46 CFR 182.455(b)(4). 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2021
Resolved
Shutoff valves installed so as to close against the fuel flow must be fitted in the fuel supply line. Shut off valve does not operate as intended.
46 CFR 182.455 (b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2021
Resolution: Witnessed satisfactory operational test of fuel shut off valves.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 December 2021
Resolved
Every vessel must have a FCC licensed technician conduct a safety exam and issue a safety radiotelephony certificate. Vessel does not have a valid certificate, restricted operation to within 1000 ft from shore.
46 CFR 184.502
47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 17 December 2021
Resolution: Valid FCC safety radiotelephony certificate issued to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2021
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Audible alarm is not heard at the operating station.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2021
Resolution: Witnessed satisfactory operational test of bilge alarms (audible and visual).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2021
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2021
Resolution: Completed annual examination. See activity #7368176
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 August 2020
Resolved
46 CFR 180.70(a)(2): A vessel of mre than 26 feet, but not more than 46 feet, must carry a minimum of one life buoy not less than 24 inches. Life bouy was unserviceable and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2020
Resolution: Lifebuoy was replaced and marked accordingly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 August 2020
Resolved
46 CFR 184.710: A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit had expired medicines that need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2020
Resolution: All expired medcine was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 August 2020
Resolved
46 CFR 183.420: All vessels must have navigation lights that are in compliance with the applicable section of the international and inland Navigation Rules. Starboard navigation and anchor light were not operational and need to be repaired
Action required: 705 - Other - as specified
Resolved 25 August 2020
Resolution: All nav lights were fully operational.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 August 2020
Resolved
46 CFR 182.610(a)(1): Avessel must be provided with a main steering gear that is of adequate strenth and capable of steering the vessel at all service speeds. Hydraulic steering hose was wasted and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2020
Resolution: New hydraulic hose was purchased and installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 August 2020
Resolved
46 CFR 16.205(b): Upon written request of an employer, Cammandant (CG-INV) will review the employer's chemical testing program to determine compliance with the provisions of this part. 2020 MIS has not been submitted for review.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2020
Resolved 25 August 2020
Resolution: 2020 MIS report was submitted as required and operator provided for review.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 March 2019
Resolved
Provide 4 more approved flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Owner provided 4 more approved flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2019
Resolved
Provide 1 more type I child PFD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Owner provided 1 more approved Type I child PFD.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2019
Resolved
Prove proper operation of the port emergency fuel shut-off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2019
Resolution: Owner proved proper operation after installing new cable.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 March 2019
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is prohibited from operations until a drydock examination and an internal structural exam has been completed by a US Coast Guard Marine Inspector. 46 CFR 176.600 (c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2019
Resolution: Completed credit drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2019
Resolved
Re-weld broken STBD shaft strut.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2019
Resolution: Shaft strut has been re-welded and re-installed.
Communications › Radio Communications › EPIRB
Issued 9 April 2018
Resolved
Vessel's EPIRB hydrostatic release was expired. Vessel is restricted to operate within 3 miles of shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2018
Resolved 12 April 2018
Resolution: Vessel provided proof of new hydrstatic release.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 February 2016
Resolved
Provide FCC Radio Telephony certificate.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Vessel provided FCC Radio Telephony certificate.
Fire Fighting › Fire Bucket › Quantity
Issued 22 February 2016
Resolved
Provide 1 additional fire bucket to complete total of 3 required.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Vessel provided 1 additional fire bucket to complete total of 3 required.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 22 February 2016
Resolved
Provide 1 additional child's PFD to meet COI requirement.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Vessel provided additional child's PFD to meet COI requirement.
Documentation › Logs/Records › Drug Test Records
Issued 22 February 2016
Resolved
Provide drug and alcohol policy and EAP hotline number.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Vessel provided drug and alcohol policy and EAP hotline number.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 22 February 2016
Resolved
Amend emergency procedures to reflect MOB operation(s) on board vessel.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Vessel ammended emergency procedures to reflect MOB operation(s) on board vessel.
Engineering › Steering Gear System › Rudder
Issued 22 February 2016
Resolved
Provide rudder stops or proof of internal range restriction.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 22 February 2016
Resolution: Vessel provided proof of internal range restriction of steering gear via hydraulic ram limitations.