MAURY USCG vessel records
← All vessels

BW PASSAT

BW PASSAT is a 2015 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in October 2025, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 6 October 2025.

Built
2015
Last inspected
6 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 October 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9674854
1331568
Flag
MARSHALL ISLANDS
Maury page id
psix-1331568

Documentation record

Tonnage as PSIX records it46945 - Convention (Subpart B), Gross Ton
53701 - Dead Weight, Metric Ton
73415 - Displacement, Metric Ton
18825 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

6 October 2025 COC-GAS Renew · PSC B · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8243252
1 July 2024 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7938752
23 May 2023 Administrative Inspection · PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7694631
15 April 2022 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7424503
15 April 2022 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7433958
11 June 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7257190
19 January 2021 COC-GAS Annual · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7122682
10 November 2019 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6850556
10 October 2018 Administrative Inspection · COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6556024
30 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6489256
3 January 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6332230
22 September 2017 PII Safety Exam · Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6269706
4 March 2016 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5824739
3 March 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5826399

Deficiency record · 3

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 10 October 2018 Resolved
No person may operate a vessel unless that person complies with all limitations in the endorsement on the vessel's certificate of compliance (COC). Vessel's COC states that vessel is authorized to carry and transfer cargo in U.S. waters in accordance with it's subchapter O endorsement(SOE). Subject's vessels aft mast riser does not comply with 46 CFR 154.805(e) and IBC 8.2.10. Until the vessel makes permanent modifications at next drydock, SOE section 12.a requires that "the crew must be familiar with the Exmar Ship Management interim safety procedures regarding the control of cargo tank pressure. PSCOs boarded subject vessel while vessel was on cargo waiver and making preparations to commence loading operations. There was no objective evidence that "permit to work - emergency preparedness/mitigating actions in case of gas release from aft mast", revision 8, had been completed for this cargo operation. 46 CFR 154.1808 10c
Action required: 10 - Deficiency Rectified
Resolved 10 October 2018
Resolution: PSCOs observed crew hold tabletop training/discussion of risk assessment/interim safety procedures, as led by chief mate, prior to completion of exam and resumption of cargo ops.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 October 2018 Resolved
Electrical installations should be such as to minimize risk of fire and and explosion from flammable products. Airlock alarm on cargo deck area outside airlock door found with cracked housing, compromising the integrity of the enclosure. PSCOs observed visible water inside the fixture. This provides objective evidence that the fixture is no longer fully explosion-proof as originally designed. 74 SOLAS 14 VII/13.1 REF IBC 93/10.1.2 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2018
Resolved 27 November 2018
Resolution: Received documentation from vessel master showing installation of new airlock alarm.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 22 September 2017 Resolved
CARGO - 1160 HOLDS AND TANKS - The vent mast for cargo tank #4, aft of the electric motor room does not meet 25m distance requirement. Flag equivalence determined insufficient evidence of compliance with 46cfr154.32 74SOLAS(14)VII/13.1 IGC(93)8.2.10 (50abc)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 30 July 2018
Resolution: Vessel subject to special restrictions listed in new SOE 30JUL2018.

Ownership record