MAURY USCG vessel records
← All vessels

BW SIROCCO

BW SIROCCO is a 2015 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in July 2026, along with 9 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 6 July 2026.

Built
2015
Last inspected
6 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 July 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9686376
1331569
Flag
MARSHALL ISLANDS
Maury page id
psix-1331569

Documentation record

Tonnage as PSIX records it46943 - Convention (Subpart B), Gross Ton
53558 - Dead Weight, Ton
73415 - Displacement, Ton
18825 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

6 July 2026 Administrative Inspection · PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8410252
13 May 2025 COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8133256
4 May 2024 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7900633
12 January 2023 Administrative Inspection · COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7618133
3 December 2021 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7356997
19 November 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7098355
29 October 2020 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7082962
29 October 2019 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6837312
28 November 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6588690
30 October 2018 Administrative Inspection · COC-GAS Renew · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6569640
18 July 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6483471
28 June 2018 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6458600
20 March 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6375640
12 January 2018 Ballast Water Examination · Deficiency Check · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6336118
27 October 2016 Deficiency Check · Administrative Inspection · COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6028866

Deficiency record · 9

12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 30 October 2018 Resolved
Gas detection equipment should be so designed that it may readily be tested. Testing and calibration should be carried out at regular intervals. Suitable equipment and span gas for this purpose should be carried on board. Ship's inventory stated that two span gas bottles should be on board. Crew provided one bottle that was nearly empty with no other suitible span gas on board. 74 SOLAS(14) VII/13.1 REF IGC 93/13.6.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2018
Resolution: Vessel provided receipt and pictures of span gas that was received on board the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 October 2018 Resolved
Electrical Installations should be such as to minimize the risk of fire and explosion from flammable products. PSCOs found two explosion proof lights to no longer be safe for operation in the gas dangerous zone posing a threat of fire and explosion. The light outside the compressor room door was found to have standing water inside and the light on the starboard forward side was found to have electrical tape wrapped around the outside and also had standing water inside the light. 74 SOLAS(14) VII/13.1 REF IGC 93/10.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 4 December 2018
Resolution: Received receipt showing delivery of 4 new explosion-proof lights onboard vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 30 October 2018 Resolved
Pressure relief valves should be set and sealed by a competent authority acceptable to the Administration. A record of this action, including the values of set pressures, should be retained aboard the ship. PSCOs found that the cargo tank #3 starboard at sea (i.e. 0.25 bar) MARV seal was missing. 74SOLAS(14) VII/13.1 REF IGC 93/8.2.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 7 December 2018
Resolution: Received service report, endorsed by RO (LR), stating that the MARV had been tested and re-sealed.
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 30 October 2018 Resolved
Gas detection equipment acceptable to the Administration should be provided (IGC 13.6.1). Alarms should be activated when the vapour concentration reaches 30% of the lower flammable limit (IGC 13.6.10). Fixed gas detection system for hold spaces has sensor with readout of % LEL inside cabinet and then LEL readout display on exterior of cabinet. When gas was applied, alarm activated but LEL readout on the exterior of the cabinet remained at 0% LEL. LEL readings are not being transmitted from the LEL detector to the display on the exterior of the cabinet. 74SOLAS (14) VII/13.1 REF IGC 93/13.6
Action required: 10 - Deficiency Rectified
Resolved 30 October 2018
Resolution: Crew fixed electrical issue and exterior panel now reads close to interior reading. Exterior panel reads 1.3% LEL when interior detector reads 0.0% LEL. Crew will continue to work on to make readings the same.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Trunking
Issued 12 January 2018 Resolved
#01 –1160- Holds and Tanks -Cargo tank pressure relief valve vent exits should be arranged at a distance at least equal to B or 25m, whichever is less, from the nearest air intake or opening to accommodation spaces, other gas safe spaces. The vent mast for cargo tank #4, aft of the electric motor room does not meet 25m distance requirement. Flag equivalence determined insufficient evidence of compliance with 46CFR154.32.This deficiency is issued with a due date of 6 months form the vessel’s arrival to the US in accordance with MSC Letter C1-1703350 dated 22SEP17. Due NLT 12JUL18 a/b/c.
Action required: 705 - Other - as specified
Due 12 July 2018
Resolved 28 June 2018
Resolution: Issued new Sub O endorsement.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 12 January 2018 Resolved
#02-1138- Liquefied Gases in Bulk – A gas carrier shall comply with the requirements of the International Gas Code. Electrical equipment should not be installed in hazardous location unless it conforms with the standards not inferior to those acceptable to the Organization (IEC60092-502). PSCOs observed one explosion-proof light located in gas dangerous zone above #2 tank dome to have significant amount of salt inside light. This provides objective evidence that the light no longer conforms to the requirements for flameproof/explosion-proof lights. 74SOLAS(14CONS)VII/13.1 IAW ref IGC93/10.1.4 50 a/c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 20 March 2018
Resolution: Received email from class (LR) confirming replacement of light fixture.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 12 January 2018 Resolved
#03 -2535- ISM- The company should ensure that all personnel involved in the company’s SMS have an adequate understanding of relevant rules regulations, codes and guidelines. Company (Exmar Shipmanagement, NV) was issued MSC Letter CI-1703350 on 22SEP17 regarding after mast riser location not complying w/ 46CFR154.805. Paragraph 3 of this letter requires that “if any of the vessels will be loading cargo in the US prior meeting (the requirements of 46CFR154.805) then the vessel must have onboard procedures to respond to tank venting, and the crew must demonstrate familiarity with these procedures to the satisfaction of the [name withheld] asked by the attending PSCOs, vessel crew was unable to present an onboard procedure. After some time a procedure was presented for the sister vessel LEVANT, but this procedure had not been read or signed by the vessel’s crew. Develop a ship-specific onboard procedure to respond to uncontrolled tank venting and ensure all crew members are familiar with this procedure. 74SOLAS(14CONS)IX/3.1 IAW ref: ISM Code 6.4 17c
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2018
Resolution: Received ship-specific risk assessment from vessel master, signed by all members of crew. Copy uploaded into 'Documents' tab.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 12 January 2018 Resolved
#4 -0615- Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 min. Before the ship leaves and all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue boat will not start. 74SOLAS(14CONS)III/20.2 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 13 January 2018
Resolution: Rescue boat repaired and operating satisfactorily in presence of Coast Guard PSCO.
Documentation › Certificates/Documents › International Certificate of Fitness (IGC Code)
Issued 27 October 2016 Resolved
0130-Liquefied Gas un bulk cof/GC-code- The construction and equipment of liquefied gas carriers certified to carry noxious liquid substances listed in the applicable Gas Carrier Code shall be deemed to be equivalent to the construction and equipment requirements contained in regulations 11 and 12 of this Annex, provided that the gas carrier meets the following conditions as listed. Vessel was not
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2016
Resolution: Vessel was able to attain the amended ICOF recognizing the correct cargo. Corrected on the spot.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.