MAURY USCG vessel records Sign in
← All vessels

BW LEVANT

BW LEVANT is a 2015 tank ship. The Coast Guard has recorded 25 inspections since 2015, most recently in May 2026, along with 5 deficiencies and 4 operational controls.

Records from 2015 to 2026. Most recent: inspection, 9 May 2026.

Built
2015
Last inspected
9 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9686388 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A3802
1331570
Flag
MALTA
—
Maury page id
psix-1331570

Inspections, by type

…with no type recorded6
Years with a record 11 calendar years (2015–2026)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it46943 - Convention (Subpart B), Gross Ton
53658 - Dead Weight, Metric Ton
73415 - Displacement, Metric Ton
18825 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LINDSEY FOSS Towing Vessel · MISLE 391286 · 15 December 2019 · activity 6876148GARTH FOSS Towing Vessel · MISLE 391287 · 15 December 2019 · activity 6876148HARRIS II Towing Vessel · MISLE 435907 · 26 September 2016 · activity 6009976H DOUGLAS M Towing Vessel · MISLE 1375242 · 26 September 2016 · activity 6009976

Inspection history · 25

9 May 2026 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8359294
27 December 2024 Administrative Inspection · PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8051308
18 October 2024 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8021100
1 December 2023 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7833444
30 November 2023 COC-GAS Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7831904
14 October 2022 COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7573848
13 October 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7577118
19 November 2021 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7348668
14 November 2021 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7350477
9 October 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7074510
8 October 2020 PSC B · COC-GAS Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7073960
5 October 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7071560
15 December 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6874079
15 December 2019 Loadline Exam · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6874561
15 December 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6876148
1 October 2019 COC-GAS Renew · Ballast Water Examination · Administrative Inspection · ISPS II Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6824863
22 September 2018 COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6546082
6 July 2018 In-Service Inspection · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6468422
11 January 2018 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6336157
11 September 2017 Ballast Water Examination · COC-GAS Renew · ISPS II Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6256321
19 December 2016 COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6058919
26 September 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6009976
3 September 2016 PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5990926
2 September 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5991058
1 December 2015 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5769417

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 November 2023 Resolved
SMOKE DETECTOR ABOVE INCINERATOR WAS DAMAGED AND INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 December 2023
Resolution: Received report from Lloy'ds of London attesting to the sufficient replacement and repair of the smoke detector mounted above the incinerator in the engine room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 December 2019 Resolved
ICLL (88) An. 15: After any survey of the ship under article 14 bas been completed, no change shall be made in the structure. Vessel's hull was punctured when it allided with morring dolphin, resulting in flooding the #1 Port ballast tank and possibly other damage under the water line.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 January 2020
Resolved 5 October 2020
Resolution: Vessel submitted a class report attesting to satisfactory repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 October 2019 Resolved
0414 - Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least 3 consecutive starts. A second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demonstrated to be effective. Emergency diesel generator could not be started after multiple attempts using the battery as the primary means of starting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2019
Resolution: Received LR class report attesting to the vessel receiving replacement batteries. Battery start on emergency generator is now operational.
Deck/Cargo › Cargo Stowage › General
Issued 11 September 2017 Resolved
The airlock should consist of 2 steel doors that are substantially gas tight and self closing. The outside airlock door is no longer gas tight when fully closed and the self closing mechanism is not working properly 74 SOLAS (14) CII/13.1, IGC CODE 3.6.1 & 3.6.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2017
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 11 September 2017 Resolved
Cargo tank pressure relief valve vent exits should be arranged at a distance at least equal to 3 or 25M, whichever is less from the nearest air intake or opening to accommodation spaces…cargo tank #4 vent mast aft of cargo motor room does not must 25m distance requirement. Flag equivalency determined to be insufficient evidence of compliance with 46CFR154. 74SOLAS(14)VII/13,IGC Code 8.2.10
Action required: 705 - Other - as specified
Due 11 July 2018
Resolved 6 July 2018
Resolution: SOE imposed special restriction to modify venting construction to comply with 46CFR154.805(e) prior to next U.S. port call after next drydock.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.