Records from 1998 to 2005. Most recent: inspection, 11 March 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 2 April 2004
Resolved
DAPI program was not available for inspection.
Action required: 705 - Other - as specified
Resolved 2 April 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 April 2004
Resolved
Did not complete underway drills due to inoperable bilge pump in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 2 April 2004
Resolved
Liferaft was at servicing facility and not available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 April 2004
Resolved
First aid kit contained expired eyewash, aspirin and sea sickness pills. Update first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2004
Engineering › Bilge Water Management System › Pump
Issued 2 April 2004
Resolved
High level alarm did not sound and bilge pump did not operate when compartment (lazarette) was flooded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2004
Lifesaving › Inflatable Liferafts › Servicing
Issued 2 April 2004
Resolved
Liferaft was as servicing facility at time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2004
Lifesaving › Lifebuoys › Serviceable
Issued 2 April 2004
Resolved
Ring lifebuoy was found deteriorated. Replace ring lifebouy and line (improper type).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2004
Lifesaving › Inflatable Liferafts
Issued 2 April 2004
No resolution recorded
Liferaft was at servicing facility at time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolution: Inadverently added to deficiency list.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 April 2004
Resolved
Replace one child size life jacket, ensure proper label. Paint remover was spilled on child size lifejacket. Jacket condemned, removed from service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2004
Navigation › Piloting/Steering › Compass Deviation Table
Issued 2 April 2004
Resolved
Provide compass deviation table.
Action required: 705 - Other - as specified
Resolved 2 April 2004
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 2 April 2004
Resolved
Provide navigation publications.
Action required: 705 - Other - as specified
Resolved 2 April 2004
Navigation › Piloting/Steering › Marine Charts
Issued 2 April 2004
Resolved
Provide updated charts for area of operation. Last chart date, 1992 with no corrections.
Action required: 705 - Other - as specified
Resolved 2 April 2004
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 April 2004
Resolved
Provide current US Coast Pilot and Light List.
Action required: 705 - Other - as specified
Resolved 2 April 2004
Navigation › Piloting/Steering › Marine Charts
Issued 10 April 2003
No resolution recorded
Provide current charts for area of operation. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Miscellaneous Items
Issued 10 April 2003
Resolved
Provide line for two fire buckets.
Condition: Unknown
Due 24 April 2003
Resolved 29 April 2003
Resolution: Rcvd phone call from master confirming cmpliance.
Communications › Radio Communications
Issued 10 April 2003
Resolved
Renew hydrostatic release for EPIRB. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 24 April 2003
Resolved 29 April 2003
Resolution: Rcvd phone confirmation from master indicating compliance.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 April 2003
Resolved
Provide splint for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 24 April 2003
Resolved 29 April 2003
Resolution: Rcvd phone confirmation from master indicating compliance.
Construction/Loadline › Hull
Issued 10 March 2003
Resolved
Sand/reglass hull blisters port side as marked. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Due 21 March 2003
Resolved 31 March 2003
Resolution: Hull blisters repaired.
Construction/Loadline › Penetrations
Issued 10 March 2003
Resolved
Repair/reglass port and stbd side scupper borders.
Condition: Unknown
Due 21 March 2003
Resolved 31 March 2003
Resolution: Scupper borders re-glassed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 10 March 2003
Resolved
Tighten engine mounting bolts. LEGACY COMPONENT DESC: Bedplate
Condition: Unknown
Due 21 March 2003
Resolved 31 March 2003
Resolution: Engine mounts tightened.
Electrical › Lighting (service)
Issued 10 March 2003
Resolved
Remove exposed wiring and old light fixture from lazzerette. LEGACY COMPONENT DESC: Conductor
Condition: Unknown
Due 21 March 2003
Resolved 31 March 2003
Resolution: Unused wiring & fixture removed.
Construction/Loadline › Penetrations
Issued 10 March 2003
Resolved
Replace broken engine access hatch port side in wheelhouse.
Condition: Unknown
Due 21 March 2003
Resolved 31 March 2003
Resolution: Access hatch renewed.
Engineering › Steering Gear System
Issued 10 March 2003
Resolved
Properly mount steering hydraulic block and replace missing hose clamps as necessary. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Unknown
Due 21 March 2003
Resolved 31 March 2003
Resolution: Hydraulic block properly remounted.
Deck/Cargo
Issued 10 March 2003
Resolved
Renew mounting hardware on deck for boom support. LEGACY COMPONENT DESC: Boom
Condition: Unknown
Due 21 March 2003
Resolved 31 March 2003
Resolution: Boom mounting hardware replaced.
Navigation › Piloting/Steering
Issued 27 June 2002
Resolved
Provide all required navigation lights as required by Navigation Rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Due 25 July 2002
Resolved 25 July 2002
Resolution: Sighted portable green over white fishing lights.
Navigation › Piloting/Steering
Issued 27 June 2002
Resolved
Provide proper day shape for fishing as per the Navigation Rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 705 - Other - as specified
Due 12 July 2002
Resolved 18 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 27 June 2002
Resolved
Make proper repairs to the hand rails on the cabin. LEGACY COMPONENT DESC: Deck Rail
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 27 June 2002
Resolved
Provide proper life lines for the Port and Starboard entry ports for passengers. LEGACY COMPONENT DESC: Lifeline
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 27 June 2002
Resolved
Remove the ends of the bolts in the pilot house that are personal hazards.
Due 12 July 2002
Resolved 18 July 2002
Stability
Issued 27 June 2002
Resolved
Prove the vessel rests on a even keel at the dock with no added weights as per the stability letter. LEGACY COMPONENT DESC: Show vessel on an even keel
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Electrical › Mast
Issued 27 June 2002
Resolved
Remove or conect the wires in the mast that are dead ended.
Due 12 July 2002
Resolved 25 July 2002
Engineering › Bilge Water Management System
Issued 27 June 2002
Resolved
Prove proper operation of bilge alarm system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 June 2002
Resolved
Place gaurd around the new exhust stack to prevent someone from getting burned. LEGACY COMPONENT DESC: Piping (exhaust)
Due 12 July 2002
Resolved 18 July 2002
Engineering › Fuel Oil Service System
Issued 27 June 2002
Resolved
Find and correct the leaks in the fuel piping in way of the racor filter. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Engineering › Non-conventional Propulsion/Steering
Issued 27 June 2002
Resolved
Find and fix the leaks in the hydraulic system. LEGACY COMPONENT DESC: Hydraulic system
Due 12 July 2002
Resolved 18 July 2002
Lifesaving › Lifebuoys
Issued 27 June 2002
Resolved
Place proper amount of retro tape on the ring buoy.
Due 12 July 2002
Resolved 18 July 2002
Construction/Loadline › Penetrations
Issued 27 June 2002
Resolved
Reduce the shaft packing leak to the maufactures recomended amount. LEGACY COMPONENT DESC: Pipe Flange
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Deck/Cargo › Mooring/Anchoring
Issued 27 June 2002
Resolved
Provide a proper size shackle and swivel for the anchor. LEGACY COMPONENT DESC: Anchor Shackle
Due 12 July 2002
Resolved 18 July 2002
Deck/Cargo › Fishing
Issued 27 June 2002
Resolved
Remove all chaffed lines from the boom, mouse all hooks, and seize all shackles in the boom arrangment. LEGACY COMPONENT DESC: Boom
Due 12 July 2002
Resolved 18 July 2002
Deck/Cargo › Fishing
Issued 27 June 2002
Resolved
Provide means to place safety pin in place on the boom. LEGACY COMPONENT DESC: Safety pin
Due 12 July 2002
Resolved 18 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 27 June 2002
Resolved
Repair or replace the deck hatch in the pilot house portside. LEGACY COMPONENT DESC: Deck hatch
Due 12 July 2002
Resolved 18 July 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 27 June 2002
Resolved
Prove proper operation of fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Fire Fighting › Miscellaneous Items
Issued 27 June 2002
Resolved
Provide two (2) more fire buckets. LEGACY COMPONENT DESC: Fire buckets
Due 12 July 2002
Resolved 18 July 2002
Navigation › Piloting/Steering
Issued 27 June 2002
Resolved
Prove proper operation of emergency steering including proper deck markings. LEGACY COMPONENT DESC: Emergancy steering
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 27 June 2002
Resolved
Seal opening in the pilot house deck portside aft where the ventilation pipe was run. LEGACY COMPONENT DESC: Quantity of Gas
Due 12 July 2002
Resolved 18 July 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 June 2002
Resolved
Repair or replace the raw water pump so that it does not leak. LEGACY COMPONENT DESC: Raw water pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2002
Resolved 18 July 2002
Personnel › Training
Issued 27 June 2002
Resolved
Preform satifactory Man of Board drill. LEGACY COMPONENT DESC: MOB drill
Action required: 705 - Other - as specified
Due 12 July 2002
Resolved 18 July 2002
Engineering
Issued 20 March 2001
Resolved
LABEL F/O SUPPLY AND RETURN VALVES.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Engineering
Issued 20 March 2001
Resolved
MDE GAGES NEED TO BE CLEARLY MARKED.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Deck/Cargo
Issued 20 March 2001
Resolved
REPLACE WINCH MOUNTING BOLTS WITH LONGER BOLTS OF PROPER GRADE.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Navigation
Issued 20 March 2001
Resolved
ADD RUDDER ANGLE MARKINGS TO DECK FOR EMERG TILLER OPERATORS USE.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Fire Fighting
Issued 20 March 2001
Resolved
Install approved smoke detection system IAW 177.410(c)(3)
Condition: Unknown
Due 20 May 2001
Resolved 30 July 2001
Accommodation/Occupational Safety
Issued 20 March 2001
Resolved
need consistant pass orentation procedure card.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Accommodation/Occupational Safety
Issued 20 March 2001
Resolved
LABEL VENTS AND ACCESS COVERS ON DECK.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Fire Fighting
Issued 20 March 2001
Resolved
PROVIDE COVER FOR GALLEY VENT.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Accommodation/Occupational Safety
Issued 20 March 2001
Resolved
PROVIDE STATION BILL FOR DRILLS.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Navigation
Issued 20 March 2001
Resolved
Install operable radar before venturing beyond Lakes, Bays and Sounds route.
Condition: Unknown
Due 30 September 2001
Resolved 30 July 2001
Electrical
Issued 15 January 2001
Resolved
Provide electrical dwg showing how electrical vent motor (for dischg vent in engine room) ties in to vessel's electrical system.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Engineering
Issued 15 January 2001
Resolved
Install SAE 1942 spec flexible hose for fuel piping system OR prove that presently installed hose meets spec 1942.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Fire Fighting
Issued 15 January 2001
Resolved
Comply with paragraphs (1) and (2) of MSC LEtter dated MAr 7, 2001, Re: Fire Detection System.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Electrical
Issued 15 January 2001
Resolved
Submit 1-line electrical diagram of how fireboy System an dsmoke detection system (Hiller) tie into vessel's electrical system.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Engineering
Issued 15 January 2001
Resolved
Instal ventilation system in engine space such that_x001C_ - both intake duct and discharge duct are 4.25" diameter each_x001C_ - indicaiton at or around dampers is made that this is to be used only in emergency situation (also, paint red)
Condition: Unknown
Due 23 July 2001
Resolved 13 August 2001