Records from 2016 to 2025. Most recent: inspection, 4 September 2025.
Inspection history · 21
4 September 2025
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8226771
13 August 2025
Drydock Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8197555
24 October 2024
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8019261
25 October 2023
DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7813555
11 August 2023
Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7765672
17 November 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7579022
10 November 2021
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7349091
3 November 2021
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7332454
16 August 2021
Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7288044
28 October 2020
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7086079
24 September 2020
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7053363
1 November 2019
DAPI Audit · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6847303
24 October 2019
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6839370
20 August 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6789393
14 August 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6774482
14 June 2019
Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6710833
7 November 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6576240
11 January 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6421820
5 December 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6318239
31 August 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6256344
12 December 2016
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6055152
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 October 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have updated drills logged.
46 CFR 185.520 (f)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 October 2024
Resolved 24 October 2024
Resolution: Drills logged.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 November 2019
Resolved
Supervisory personnel must receive at least 60 minutes of Employee Assistance Programs training. Master needs to provide certificate of required training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2019
Resolved 7 November 2019
Resolution: Master provided completed EAP training certificate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2019
Resolved
Portable extinguishers must be maintained in accordance with NFPA 10. Identified fire extinguisher with excessive corrosion. Replace fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2019
Resolved 29 October 2019
Resolution: Vessel replaced fire extinguisher with excessive corrosion with new extinguisher
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2019
Resolved
The life buoy grab line shall be of suitable buoyant synthetic material having a minimum breaking strength of 1350 pounds. Life buoy grab line was dry-rotted and broke during inspection. Replace grab line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2019
Resolved 29 October 2019
Resolution: Owner replaced degraded life buoy grab line new new line
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 October 2019
Resolved
The items contained in first-aid kit shall be as listed in table 160.041-4(b). Found the ammonia inhalants were expired. Replace ammonia inhalants.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2019
Resolved 29 October 2019
Resolution: Expired Ammonia inhalants were replaced in first aid kit.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 December 2017
Resolved
Properly label storage for 03 Child and 02 Adult life jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 11 December 2017
Resolution: Pictures of new markings for storage received via e-mail.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 December 2017
Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Expired items were individually purchased. Entire first aid kit was not replaced.
Documentation › Markings/Placards › Lifejacket Placard
Issued 5 December 2017
Resolved
Replace lifejacket donning placard for models carried onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 11 December 2017
Resolution: Proper lifejacket donning placard was posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 December 2016
Resolved
Provide annual fire servicing report for portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 13 December 2016
Resolution: Received annual maintenance report from First City Fire Equipment, INC.