SPAR PYXIS
SPAR PYXIS is a 2015 freight ship. The Coast Guard has recorded 13 inspections since 2016, most recently in December 2022, along with 1 deficiency and 2 operational controls.
Records from 2016 to 2022. Most recent: inspection, 22 December 2022.
- Built
- 2015
- Last inspected
- 22 December 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 1 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9701932 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LATQ7
1333748
Flag
NORWAY
—
Maury page id
psix-1333748
Inspections, by type
…with no type recorded2
Years with a record
5 calendar years (2016–2022)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it63266 - Dead Weight, Metric Ton
75165 - Displacement, Metric Ton
36311 - Convention (Subpart B), Gross Ton
21597 - Convention (Subpart B), Net Ton
75165 - Displacement, Metric Ton
36311 - Convention (Subpart B), Gross Ton
21597 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
22 December 2022
PSC B · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7612093
10 December 2021
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7365835
8 December 2021
ISPS Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7364458
29 November 2021
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7358352
19 January 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7126851
4 November 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6843520
7 August 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6761346
8 September 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6535525
7 September 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6534576
31 May 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6422626
17 December 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6057095
17 December 2016
COE-Offshore
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6058461
5 February 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5806326
Deficiency record · 1
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 22 December 2022
Resolved
Vessels operating in the U.S. with an installed Ballast Water Management System (BWMS) that has been approved by the Coast Guard under 46 CFR 162 must be marked. The BWMS must be marked IAW 46CFR162.060-22, nameplate must include the Coast Guard approval number assigned to the BWMS in the certificate of approval. No approval plate could be located on the BWMS, BWMS was previously approved as an AMS system. Vessel was unable to produce BWMS user manual indicated in the USCG type approval certificate. Due to the missing nameplate and user manual, PSCO could not determine if the BW treatment system is a CG approved system.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.