Records from 2016 to 2025. Most recent: inspection, 29 December 2025.
Inspection history · 10
29 December 2025
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8287987
20 December 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8285569
12 December 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8278507
6 June 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151206
29 July 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7969759
15 July 2024
COE-Administrative
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7959151
23 May 2022
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7457230
27 September 2020
PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7066002
26 September 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7319195
1 February 2016
ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5807247
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 December 2025
Resolved
The machinery, boilers, and other pressure vessels, associated piping system and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed water leaking from the main engine air cooler gasket. 15(AC)
Solas 74(04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 26 December 2025
Resolved 29 December 2025
Resolution: Received DNV statement attesting to replacing the gasket on the M/E air cooler.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 December 2025
Resolved
The purpsoe of this regulation is to prevent the ignition of combustible materials or flammable liquid. PSCO observed oil accumulation under main engine lube oil feed pump and main engine lube oil filter. 40(AC)
Solas 74(24) II-2/4.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2025
Resolved 29 December 2025
Resolution: Received DNV statement attesting to repairs being made on the LO feed pump and M/E lube oil filter.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 December 2025
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL LEAKING FROM MAIN DIESEL ENGINE CYLINDER #8 & #12 FROM THE FUEL PUMP GASKET. ADDITIONALLY OBSERVED ACCUMULATION OF OIL ON #1 & #3 CYLINDER FOR MAIN DIESEL ENGINE.
74 SOLAS (04) II-2/4.1.1
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 December 2025
Resolution: Vessel provided class surveys with permanent corrections made.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Water, pipes, tanks
Issued 12 December 2025
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DNAGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED TEMPORARY REPAIR TO WATER GUAGE LEVEL ON THE COOLING WATER EXPANSION TANK FOR MAIN ENGINE.
74 SOLAS (24) I/11a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2025
Resolution: Vessel provided class survey with certificate of class with a completion date for permanent repairs for March of 2026.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 December 2025
Resolved
THE INTERNATIONAL LOAD LINE CERTIFICATE SHALL NOT BE DELIVERED TO THE SHIP UNTIL THE OFFICER OF THE SURVEYOR ACTING UNDER THE PROVISIONS OF ARTICLE 13 OF THE CONVENTION HAS CERTIFIED THE MARKS ARE CORRECTLY INDICATED ON THE SHIP'S SIDE. VESSELS LOAD LINE MARKINGS DO NOT REFLECT THE LOAD LINE MARKS AS INDICATED ON THE SHIP CERTIFICATE.
ICLL 66 ANNEX I/9
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2025
Resolution: Vessel provided policy document stating that marks of authority for load line marking are satisfactory due to branding name change of DNV-GL to DNV.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 July 2024
Resolved
For this purpose, the following functional requirments shall be met: ignition sources shall be seperated from combustible materials and flammable liquids. PSCO found 11 buckets of oil next to incinerator.
74SOLAS(09)II-2/4.1.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 July 2024
Resolved 29 July 2024
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 29 July 2024
Resolved
Emergency escape breathing devicies shall comply with the fire safety systems code. Spare emergency escape breathing devices shall be kept onboard. PSCO discovered EEBD near autormatic door leading to shaft alley was smashed.
74SOLAS(09)II-2/ 13.3.4.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 July 2024
Resolved 29 July 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 July 2024
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light background... PSCO found paint no longer visable and deteriorated on loadline marking.
ICLL(88)8
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 July 2024
Resolved 29 July 2024
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 23 May 2022
Resolved
Following the installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufactured specifications. The PSCO was informed by ship's master that Ballast Water Treatment System is currently non-operational. Vessel is not to discharge.
33CFR151.2025(a)(1)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 May 2025
Resolution: Received required documents and uploaded. - Sector NY
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2022
Resolved
Nozzles shall be an approved dual-purpose type (i.e. spray/jet type) incorporating a shutoff. PSCO discovered that 24 nozzles on board the vessel are jet type only without the capability to adjust from the jet to spray.
74 SOLAS (2014) II-2/10.2.3.3.4
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2022
Resolved 17 July 2022
Resolution: Parts receipt received and attached. - Sector NY
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 1 February 2016
Resolved
0710: Means shall be provided to control leaks of flammable liquids. The fuel pressure regulating valve for generators #1 and #2 was found to have consistent leakage. Crew was able to control the leak in the prescence of PSC inspectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 1 February 2016
Resolution: Crew was able to control leakage and is implementing further investigation and repair.
Operations/Management › Ballast Water Managment › Sediments
Issued 1 February 2016
Resolved
2510: Ships shall maintain a Ballast Water Management Plan that shall include detailed fouling maintenance and sediment removal procedures. BWM Plan did not include these items. 10c; 33 CFR 151.2050(g)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 1 February 2016
Resolution: Master and [name withheld] were provided with sample Bio-Fouling Plan.