MAURY USCG vessel records Sign in
← All vessels

LEEWAY

LEEWAY is a 2015 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2015, most recently in April 2026, along with 3 deficiencies.

Records from 2015 to 2026. Most recent: inspection, 28 April 2026.

Built
2015
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN7189
1334087
Flag
UNITED STATES
338234000
Maury page id
psix-1334087

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2015–2026)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.3 ft × 13.8 ft × 4.0 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2015
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portANACORTES, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Net Ton
9 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN7189MMSI 338234000 · active · compulsorily equipped · granted 4 April 2023, expires 4 April 2033
WDI2627MMSI 338234000 · cancelled · compulsorily equipped · granted 23 June 2015, cancelled 27 March 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

28 April 2026 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8325399
9 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8109523
15 October 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8019452
30 April 2024 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7904276
11 April 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7668328
23 March 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7672986
16 May 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7454316
12 April 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7420313
15 July 2020 Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7019334
28 June 2019 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6729069
17 July 2018 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6405022
19 July 2017 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6291898
21 June 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6188636
15 July 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5939283
20 July 2015 Deficiency Check · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5180394

Deficiency record · 3

Engineering › Fuel Oil Service System › Hose
Issued 15 July 2016 Resolved
Install conductor between fuel fill & diesel tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Rcvd email dtd 14Aug2016 w/ pics showing installation of conductor btwn fuel fill & diesel tank.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 15 July 2016 Resolved
Install vapor block to fwd tank space bulkhead (port & stbd) (46CFR181).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Rcvd email dtd 14Aug2016 w/ pics showing installation of vapor block to fwd tank space bulkhead.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 20 July 2015 Resolved
Provide proof of the vessels FCC Safety Radio telephony Certificate.
Due 20 August 2015
Resolved 13 August 2015
Resolution: Proof was provided of vessels FCC Safety Telephony Certificate

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.