← All vessels
SHINSUNG ACCORD
SHINSUNG ACCORD is a 2014 freight ship. The Coast Guard has recorded 9 inspections since 2015, most recently in March 2026, along with 5 deficiencies and 3 operational controls.
Records from 2015 to 2026. Most recent: operational control imposed, 25 March 2026.
- Built
- 2014
- Last inspected
- 25 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9606041 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D7BY
1334114
Flag
REPUBLIC OF KOREA
—
Maury page id
psix-1334114
Inspections, by type
…with no type recorded3
Years with a record
6 calendar years (2015–2026)
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it22871 - Convention (Subpart B), Gross Ton
12522 - Convention (Subpart B), Net Ton
37063 - Dead Weight, Metric Ton
45375 - Displacement, Metric Ton
12522 - Convention (Subpart B), Net Ton
37063 - Dead Weight, Metric Ton
45375 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
25 March 2026
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8331694
20 September 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8237962
14 June 2025
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8159212
10 March 2025
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8090973
19 September 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8005405
15 August 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7981612
1 September 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7047973
12 February 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6617951
11 October 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5740281
Deficiency record · 5
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 September 2024
Resolved
Testing and inspection shall be carried out based on the guidelines developed by the organization. PSCO observed ships crew testing heat detector with blowtorch and lighter.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2024
Resolved
Fire protection systems shall be kept in good working order. PSCO observed a covered heat detector in the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 September 2024
Resolved
Fire doors in stairway enclosures shall be self-closing and be capable of closing. PSCO observed door to main machinery space was tied open with rope.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 15 August 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
PSCO observed emergency fire pump not readily available for immediate use.
74Solas(20) II-2/14.2.1.2
Operations/Management › Pollution › Control of Garbage
Issued 11 October 2015
Resolved
amrpol 2011 consolidated cons annex v/ Reg 9.2: This plan shall provide written procedures for collecting, storing, processing, and disposing of garbage includig the use of equipment on board. Metal cans were stored within the incinerator, which is not in accordance with their garbage management plan.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.