← All vessels
JOURNEY
Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG Southeast District (CGD-SE) · Other hulls named JOURNEY
JOURNEY is a 2015 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2015, most recently in July 2025, along with 14 deficiencies, 1 operational control and 1 casualty investigation in 2018.
Records from 2015 to 2025. Most recent: inspection, 21 July 2025.
- Built
- 2015
- Last inspected
- 21 July 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2018
Identity
1261728
WDI3142
1335236
Flag
UNITED STATES
367685370
Maury page id
psix-1335236
Inspections, by type
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPON SPRINGS, FL, UNITED STATES · built 2015
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI3142MMSI 367685370 · active · compulsorily equipped · granted 22 August 2025, expires 23 July 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 17
21 July 2025
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8186340
2 January 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8060352
23 July 2024
Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7967700
20 November 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7827280
7 November 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7629249
20 October 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7580782
18 November 2021
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7353192
20 March 2021
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 7162464
29 September 2020
Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7067433
19 August 2020
Administrative Inspection · Internal Structural Exam · COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7032791
25 October 2019
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6843772
22 July 2019
Internal Structural Exam · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6765941
27 November 2018
DAPI Audit · Annual Survey · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6661364
11 August 2018
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 6510147
28 July 2017
DAPI Audit · Hull Examination · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6334212
11 August 2016
Annual Inspection · Administrative Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5981680
22 July 2015
COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5192169
Deficiency record · 14
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 January 2025
Resolved
EPIRB battery expired 24 Aug2024. Renew battery.
New EPIRB has been purchased and registered.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 January 2025
Resolved
Fire extinguisher brackets need to be replaced. Brackets don't secure correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 2 January 2025
Resolved
Each life float must be individually attached to the painter by a line. Second life float needs to be attached to the painter. Retro tape needs to be new.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 July 2024
Resolved
Grind down all delamination on port side AFT side marked locations and STBD forward marked areas and repair back to original condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2024
Resolved
Both out board engines have a grounding strap that has broken lose from engine. Repair straps back to manufactured approved location.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 23 July 2024
Resolved
Repair/ replace both missing safety latches on both ladders on port and stbd side of vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 July 2024
Resolved
Replace/ repair broken head raw water suction screen for further inspection through hull valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2024
Resolved
Repair/ Replace broken pipe mount in void next to head.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 July 2024
Resolved
Vessel must conduct drydock and ISE and make any and all repairs to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 August 2020
Resolved
Starboard life float found with small chip in one corner and faded white. Conduct repairs or replace starboard life float to satisfaction of CG inspector.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 August 2020
Resolved
Update chart with correct navigation chart.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 October 2019
Resolved
Life floats require new lines and repair straps.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 October 2019
Resolved
Vessel logs must track drills and survival craft maintenance.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 25 October 2019
Resolved
Renew EPIRB registration sticker and hatch.
Casualty record · 1
30 June 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6468323
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.