A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
3 February 2026
Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8304990
12 March 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8092295
21 March 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7882791
1 March 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7872837
20 April 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7672382
20 January 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7383234
11 February 2021
COI Inspection · Deficiency Check · Hull Examination · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7139373
6 November 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6850390
19 July 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6495645
27 June 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6458734
26 October 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6298421
6 October 2017
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6284781
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2025
Resolved
For each marine casualty required to be reported by 185.202, the owner, agent, master or person in charge shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. Alcohol testing strips expired 9-30-2024, provide new means of testing.
46 CFR 185.210 (a)
Code 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2025
Resolved 18 April 2025
Resolution: Provided
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2025
Resolved
A vessel not required to have a fire main is required to have three 2 1/2 gallon fire buckets with the words fire bucket stenciled on the side. Vessel has larger buckets drill several holes at the 2 1/2 gallon (10 quart) line to ensue the bucket is light enough to use.
46 CFR 181.610
Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2025
Resolved 18 April 2025
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 April 2025
Resolved
Portable fire extinguishers must be located so that they are readily accessible and ready for use. Fire extinguisher tamper seals are missing and pin was found in the bilge. Properly mount extinguisher with pin and tamper seal to prevent discharge of fire fighting agent.
46 CFR 181.520
Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2025
Resolved 18 April 2025
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. Main propulsion engine had an oil leak near the flywheel. Submit a technical report of required gaskets or parts that were replace to correct the issue. Vessel may be used until corrected but oil sump must be checked daily to ensure full oil level.
46 CFR 182.200
Code 50 c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025
Resolved 18 April 2025
Resolution: Replaced three oil cooler lines, tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 April 2025
Resolved
All vessels must have navigation lights that are in compliance with Inland Nav Rules. Vessels stern light is not working, vessel is already restricted to day light operations due to no water light for the buoy. Replace stern light.
46 CFR 183.420
Code 705 c
Action required: 705 - Other - as specified
Resolved 18 April 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2024
Resolved
All electrical equipment and circuits must be clearly marked and identified. Battery switch for main propulsion engine is not legible and requires renewal. Relabel to the satisfaction of the attending MI.
46 CFR 183.220 (d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 10 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 5 April 2024
Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard or rail. STBD side of main propulsion engine cage has a hole that would allow someone to place arm inside engine space. Repair to the satisfaction of the attending MI.
46 CFR 177.960
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 10 April 2024
Resolution: Cage welded and repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2024
Resolved
A vessel must carry one floating water light, unless it is limited to day time operations, in which case no floating water light is required. Vessel is restricted to day light operations until a water light is provided.
46 CFR 180.70 (d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2024
Resolved 2 February 2026
Resolution: Water light was attached.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 12 March 2024
Resolution: New COI issued.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 April 2023
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry:
(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter. Flares expired. Replace flares.
Action required: 705 - Other - as specified
Due 27 April 2023
Resolved 24 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI. No lanyards. Attach lanyards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 24 April 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 February 2021
Resolved
Make permanant repairs to the chine on the port and starboard side where porosity is showing through.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 25 February 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 June 2018
Resolved
Provide new 1st aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 19 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2018
Resolved
Properly label child PFD.s stowage location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 19 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 June 2018
Resolved
Prove proper operation of fuel gauge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 19 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2018
Resolved
Prove proper operation of water light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 19 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 June 2018
Resolved
De-water forward space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2018
Resolved 19 July 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 October 2017
Resolved
Properly mount forward fire extinguisher.
Condition: Improper Installation
Due 13 October 2017
Resolved 10 October 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 October 2017
Resolved
Provide 1st aid kit with serviceable equipment.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 10 October 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 October 2017
Resolved
Provide alcohol test kits.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 10 October 2017
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 6 October 2017
Resolved
Provide current 1st aid card for vessel operator.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 10 October 2017
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 October 2017
Resolved
Provide deckhand enrolled in drug testing program.
Condition: Placed in Improper Service
Due 13 October 2017
Resolved 10 October 2017
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 6 October 2017
Resolved
Provide two additional adult PFD's and provide seperate stowage for child PFD's.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 10 October 2017
Lifesaving › Lifefloat › Lifeline
Issued 6 October 2017
Resolved
Properly mount life ring, renew 60ft line, apply new retro-reflective tape and affix line to light with clip.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 10 October 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 October 2017
Resolved
Properly use deck rail while passengers are onboard.
Condition: Improper/Lack of Maintenance
Due 13 October 2017
Resolved 6 October 2017