Tonnage as PSIX records it151559 - Convention (Subpart B), Gross Ton 83151 - Convention (Subpart B), Net Ton 156301 - Dead Weight, Metric Ton 201518 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
31 January 2026Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8304594
The fixed fire dectection and fire alarm system required inparagrapg 4.1.1 shall be so designed and the detectors so positioned as to detect rapidly the onset of fire in any part of those spaces.... PSCO observed flame detector in forward overhead of fuel oil purifier room not installed in an orientation to cover machinery in space, pipes and electrical wiring obscuring detectors line of sight, and ships crew unable to test function of detector without climbing on top of running machinery and into overhead (safety hazard).
74 Solas (09) II-2/7.4.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2025
Resolved 31 January 2026
Resolution: PSCO received Class (DNV) Survey Report attesting to the repositioning of fire detector and satisfactory testing.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 22 December 2023Resolved
EXTERNAL HIGH-PRESSURE FUEL DELIVERY LINES BETWEEN THE HIGH-PRESSURE FUEL PUMPS AND FUEL INJECTORS SHALL BE PROTECTED WITH A JACKETED PIPING SYSTEM CAPABLE OF CONTAINING FUEL FROM A HIGH-PRESSURE LINE FAILURE. A JACKETED PIPE INCORPORATES AN OUTER PIPE INTO WHICH THE HIGH-PRESSURE FUEL PIPE IS PLACED, FORMING A PERMANENT ASSEMBLY. THE JACKETED PIPING SYSTEM SHALL INCLUDE A MEANS FOR COLLECTIONS OF LEAKAGES AND ARRANGEMENTS SHALL BE PROVIDED WITH AN ALARM IN CASE OF FUEL LINE FAILURE. PSCO OBSERVED THE HIGH PRESSURE FUEL DELIVERY LINES FOR #1 CYLINDER, FORWARD AND #8 CYLINDER, AFT ARE EXCESSIVELY LEAKING.
74 SOLAS (20) II-2/4.2.2.5.2
60 ac
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 December 2023
Resolution: [name withheld] satisfactory class report attesting to proper repair of high pressure fuel lines for #1/#8 clyinders