MAURY USCG vessel records
← All vessels

FAST CAT

FAST CAT is a 2007 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in September 2025, along with 25 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 5 September 2025.

Built
2007
Last inspected
5 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH9513
1337438
Flag
UNITED STATES
Maury page id
psix-1337438

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 18

5 September 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8202149
15 June 2025 Deficiency Check · Plan Review "T" Boat · Construction Oversight · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8168969
28 May 2025 Internal Structural Exam · Examination of Repairs · Hull Examination · Vessel Attendance · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8093329
6 December 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7991284
28 November 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7738715
25 May 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7659756
9 November 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7512006
13 October 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7331471
1 June 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7212900
26 August 2020 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7043519
19 September 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6792796
30 May 2019 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6646291
11 November 2018 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6596905
10 July 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6420016
24 January 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6343285
25 May 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6148767
12 September 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5994814
7 September 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5994933

Deficiency record · 25

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 November 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. MI observed engine would continue to start after pre-engineered fixed extinguishing test when system was not in overide position.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 November 2022
Resolution: MI witnessed proper operation of simulated fixed fire suppression system MDE shutdown, starting interlock, and override functions.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 September 2020 Resolved
A pre-engineered fixed gas fire extinguishing system must have: an audible and visual indicator at the operators station. Audible and Visual Indicator faulty.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2020
Resolved 15 September 2020
Resolution: MI verified proper operation of replaced Fire-Boy alarm/overide panel. OPS tested SAT.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 August 2020 Resolved
Vessel must comply with FCC Radio Station Requirements as per 47 CFR 80. Radio Safety Certificate expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2020
Resolved 19 October 2020
Resolution: Operator submitted proof of Radio Safety Certificate. New certificate expires 19OCT2025.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2019 Resolved
Fixed fire fighting system is required to shut down the engine when activated. Engine did not shut down when system was tested. Demonstrate proper operation of the system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2019
Resolution: Verified proper operation of fixed fire fighting system
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 September 2019 Resolved
Vessel is required to have a stern light. Stern light was extinguished. Demonstrate proper opperation of the stern light
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2019
Resolved 23 September 2019
Resolution: Verified proper operation of the stern light
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018 Resolved
Provide proof of servicing and/or replacement of portable extinguisher at operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2018
Resolved 11 July 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 10 July 2018 Resolved
Provide MIS report for CY 2017 in order to verify pre-employment and random testing is being conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2018
Resolved 11 July 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 26 January 2018 Resolved
Conduct satisfactory sea trial, to include proper operation of propulsion equipment & conducting of drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Resolution: vessel conducted satisfactory sea trial, to include proper operation of propulsion equipment & conducting of drills.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 January 2018 Resolved
Recharge/Replace/Renew & have proper firefighting servicing completed on empty B-II fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Resolution: Vessel renewed fire ext.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 January 2018 Resolved
Remove fuel from STBD AFT bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Resolution: Vessel removed fuel from STBD aft bilge.
Documentation › Certificates/Documents › Permit, Other
Issued 26 January 2018 Resolved
Provide FCC Marine Radio Operator permit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 2 February 2018
Resolution: Vessel provided a copy of FCC marine radio permit.
Lifesaving › Lifefloat › Markings
Issued 26 January 2018 Resolved
Properly Label life float with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2018
Resolved 13 February 2018
Resolution: vessel properly Label life float with vessel name.
Lifesaving › Lifefloat › Float Free
Issued 26 January 2018 Resolved
Remove line and cords securing life float to mount & allow life float to be in a float free status at all times.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 January 2018
Resolved 26 January 2018
Resolution: Vessel removed all securing lines & bungee cords securing cover & life float to vessel. Allowing it to be in a float free status at all times.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 January 2018 Resolved
Renew batteries in (02) water lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2018
Resolution: Vessel renewed batteries in (02) water lights
Navigation › Piloting/Steering › Marine Charts
Issued 26 January 2018 Resolved
Provide copy of updated charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2018
Resolved 13 February 2018
Resolution: Vessel provided a copy of updated charts.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 January 2018 Resolved
Permanently mount EPIRB mounting & install EPIRB in an area for automatic float-free activation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 February 2018
Resolution: Vessel permanently mounted EPIRB mount.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 January 2018 Resolved
Properly secure Port & STBD battery boxes to include box covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 2 February 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 January 2018 Resolved
Renew/Replace all expired first-aid equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2018
Resolved 13 February 2018
Resolution: Vessel Renewed/Replaced all expired first-aid equipment.
Operations/Management › Vessel Activity › Other
Issued 24 January 2018 Resolved
Conduct a satisfactory annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2018
Resolved 2 February 2018
Resolution: Vessel conducted a satisfactory annual inspection.
Engineering › Fuel Oil Service System › Valve
Issued 12 September 2016 Resolved
Repair Fuel shut off valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 15 September 2016
Resolution: New valve installed
Operations/Management › Passenger Operations › Safety Orientation
Issued 12 September 2016 Resolved
Provide passenger safety orientation
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 13 November 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 September 2016 Resolved
Provide record of Drills
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 13 November 2016
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 September 2016 Resolved
Provide monthly EPIRB test
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 13 November 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 September 2016 Resolved
Replace clip connecting waterlight to ringbuoy.
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 13 November 2016
Operations/Management › Passenger Operations › Safety Orientation
Issued 12 September 2016 Resolved
Provide a passenger count to be retained ashore when vessel is underway.
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 13 November 2016

Ownership record