Records from 1995 to 2025. Most recent: inspection, 16 September 2025.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2024
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Replace with Coast Guard approved lights as needed.
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 9 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2024
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity.
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 9 November 2024
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 4 October 2024
Resolved
Electrical equipment must be marked with its respective current and voltage ratings. (d) Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve.
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 9 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 October 2024
Resolved
The vessel flanking hydraulic ram is leaking with no containment to prevent pollution in the navigable waters.
(a) Pumps, pipes, valves, and fittings in essential systems on vessels must meet ABS Rules for Building and Classing Steel Vessels Under 90 Meters (295 Feet) in Length(incorporated by reference, see § 136.112 of this subchapter), Part 4, Chapter 4.
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 9 November 2024
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 October 2024
Resolved
160B Semi-Portable fire extinguisher is below service pressure, repair or replace as required, update service tag to reflect.
Action required: 705 - Other - as specified
Due 5 November 2024
Resolved 9 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2023
Resolved
Each type I lifejacket must be marked with the name of the vessel and have attached a light and whistle. 6 type I lifejackets found onboard without markings. Mark as required. (Mark each Type I in block capital letters with the name of the vessel)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 November 2023
Resolved 7 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2023
Resolved
At least two lifebuoys on a towing vessel greater than 26ft must be fitted with a floating electric light under approval series 161.010 or 160.110. One lifebuoy fitted was missing a floating electric light, attach with approved light and lanyard of at least 3ft but not more than 6ft.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 November 2023
Resolved 7 November 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 19 October 2023
Resolved
Master's medical certificate unavailable for inspection. Submit request for duplicate copy of valid medical certificate and provide proof that Master received valid medical certificate.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 20 November 2023
Resolved 7 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 October 2023
Resolved
A vessel on a rivers route must carry 3 day and 3 night visual distress signals (or 3 approved under approval series 160.021 or 160.121 or 160.036 or 160.136 which are acceptable as both day and night signals). Vessel signals expired May 2023. Supply the vessel with adequate number of visual distress signals.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 20 November 2023
Resolved 7 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2023
Resolved
Each type I lifejacket must be marked with the name of the vessel. All 7 type I lifejackets found without markings. Mark as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 March 2023
Resolution: All lifejackets marked as required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 March 2023
Resolved
Each life buoy on a towing vessel must be approved under approval series 160.050 or 160.150. Life buoys found deteriorated. Renew/replace life buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 March 2023
Resolution: New life buoys purchased and properly marked
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 March 2023
Resolved
Two portable fire extinguishers do not have brackets - one in the galley and one in the E/R. Provide brackets to correctly mount the fire extinguishers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 April 2023
Resolution: New brackets installed
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 March 2023
Resolved
Fixed fire pump gauge missing. At next credit drydock, install proper fire pump gauge.
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 1 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2019
Resolved
Starboard pressure vessel not protected with a dedicated relief valve. Provide relief valve for starboard pressure vessel or ensure isolation valve is permanently opened in crossover piping.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Installed isolation valve
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 October 2019
Resolved
Chains bound up or failed when operating port and starboard remote fuel shutoff valves. Ensure that chains are properly tensioned and fully operational to close remotely.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 12 December 2019
Resolution: Chains tensioned and working properly
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 October 2019
Resolved
Heat sensors in engine room and aft galley were not tested. Provide documentation that heat sensors were tested at last fire detection servicing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 19 December 2019
Resolution: Documentation provided on testing
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 October 2019
Resolved
Starboard generator would not start. Prove proper operation of starboard generator as second means of electrical power.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 19 December 2019
Resolution: Generator was operating when onboard
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 17 October 2019
Resolved
Garbage and oil placards were outdated. Post new garbage and oil discharge placards on board vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Signs updated
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 October 2019
Resolved
General alarm placard was outdated. Post new general alarm placard with updated verbiage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Signs updated
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 October 2019
Resolved
Fire alarm pull handle on port side of engine room did not actuate alarm in engine room. Prove proper operation of pull handle to activate alarm.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Pull handle tested and actuated alarms
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2019
Resolved
Visible exhaust leak on port engine in way of turbo. Repair exhaust leak and cover with lagging.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Repaired leak and added more lagging
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 October 2019
Resolved
No fire extinguisher was located outside of flammable liquid stores on bow of vessel. Install mount for portable fire extinguisher to provide fire protection for space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Installed new fire extinguisher
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2019
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops a problem. A high bilge alarm is one of these alarms. The vessel is equipped with an alarm system that individually indicates which alarm is tripped. When the bilge high-level alarm was manually tripped, the alarm sounded on the bridge but the visual indicator did not indicate which alarm was tripped. Since the system is designed to indicate individual alarms visually, it must work as designed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Witnessed proper operation of the visual indicator
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 17 October 2019
Resolved
Each towing vessel with overnight accommodations must identify the duties and duty stations of each person on board during an emergency. This must be posted in the pilothouse and a common space. The emergency information posted includes duties of a second crew member and it was not posted in a common space. The vessel only operates with one crew member. Update emergency duty information to reflect actual crew on board and post in a common space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: New emergency duty information posted
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 17 October 2019
Resolved
Prior to getting underway for the first time on a particular towing vessel, each crew member must receive a safety orientation. No evidence was provided showing safety orientation training for the new crew member. Provide documentation showing proof training was conducted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 23 January 2020
Resolution: Saw safety orientation training record for newest crewmember
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2019
Resolved
A towing vessel with overnight accommodations and alternating watches, when pulling, pushing, or hauling alongside on or more barges must have a system to detect when its master becomes incapacitated. The secondary alarm of the pilothouse alerter system did not alarm in the galley as intended. Repair system to ensure secondary alarm activates as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 23 January 2020
Resolution: Witnessed operation of secondary alarm
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 October 2019
Resolved
A towing vessel operating on the inland rivers must carry three day and 3 night visual distress signals or 3 day/night. No visual distress signal were onboard. Supply the vessel with the required number of visual distress signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 23 January 2020
Resolution: Approved flared onboard and in an approved case
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2019
Resolved
Each life-jacket on board a towing vessel must be marked in block capital letters with the name of the vessel. None of the type I life-jackets had the vessel name. The vessel is currently awaiting a name change and will stencil all life-jackets with the new name of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 19 November 2020
Resolution: Lifejackets marked with vessel name
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2019
Resolved
Each life-jacket on board a towing vessel must have a life-jacket light and a whistle. Multiple life-jackets were found on board without the required attachments. Ensure all life-jackets on board have the required attachments.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Light and whistle attached to all Type I PFD
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2019
Resolved
No later than 22 July 2019, a health and safety plan must be implemented. No health and safety plan was provided during inspection. Provide evidence that a health and safety plan is in place and covers the requirement found in 46 CFR Subpart E.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Reviewed health and safety plan
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 October 2019
Resolved
This towing vessel is required to have a minimum of 2 lifebuoys with at least one fitted with a line, one without and line and two with floating electronic lights. All 3 lifebuoys on board are cracked and need replacing. None of the lifebuoys had floating electronic lights. Replace lifebuoys and attach at least minimum required attachments
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 23 January 2020
Resolution: 2 new lifebuoys onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Electrical systems and equipment must function properly and minimize system failures, and shock hazards. Exposed wiring was found in the overhead and under the dash of the pilothouse. Repair as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 23 January 2020
Resolution: Made exposed wiring safe
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 October 2019
Resolved
Each towing vessel must be equipped with navigation lights in accordance with 33 CFR part 84. The forward facing light was not operable. Replace/repair light to return it to proper service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 23 January 2020
Resolution: all nav lights working
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 October 2019
Resolved
A registered PE or a NICET level IV fire alarm engineering technician must certify the design and installation of the fire detection system. No proof of this certification was provided. Provide proof that system is certified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Certification provided
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Electrical systems and equipment must minimize system failure, fire and shock hazards. Multiple batteries found in the engine not in closed boxes. Place all batteries in battery boxes.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Battery boxes being utulized
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Cable hangers for overhead and vertical cable runs must be installed with metal supports and retention devices at least every 48 inches. Wire tires were used to secure overhead wire runs. Replace wire tires with metal devices.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Metal hangers used to replace wire ties
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 17 October 2019
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Belts on the fire pump and steering pumps were exposed and presented a hazard to individuals working aorund the. Install guards as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Guards installed
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 17 October 2019
Resolved
Piping for flammable or combustible liquid, seawater cooling, or firefighting systems must labeled or color-coded that enables the crew to identify its function. No Label or color-coding was found. Label and/or color code and post document describing color-coding.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Color-coding added and document posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 October 2019
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. The semi-portable was not in a location that would allow the hose to reach the engine room nor was it secured. Place in location during vessel operation to allow hose to reach the engine room and during operations secure with chain strap.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2019
Resolved 12 December 2019
Resolution: Procedure in place to properly secure semi-portable fire extinguisher during vessel operation