Records from 2016 to 2022. Most recent: inspection, 11 December 2022.
Inspection history · 14
11 December 2022
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7604942
16 February 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7397183
10 February 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7394259
19 October 2021
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7334251
19 October 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7335774
4 March 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7150121
24 October 2020
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7083044
2 July 2019
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6732556
1 July 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6732390
31 October 2018
COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6572080
20 April 2018
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6395807
13 December 2017
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6323888
4 January 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6063525
30 September 2016
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6011728
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 19 October 2021
Resolved
To discharge ballast water into the waters of the US, the master, owner, operator, agent or person in charge of a vessel subject to 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standard in 151.2030(a), use an AMS as decribed in 151.2025(a)(3), or ballast with water from a US public water system, according to the schedule in pragraph (b) of this section.
Subject vessel, of keel laid date 11JUL2014 and ballast water capacity of 21,743 m^3, is past its compliance date per the implementation schedule. Currently, vessel's installed BWTS is inoperative.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 November 2021
Resolved 4 January 2022
Resolution: Vessel conducted repairs to BWTS and submitted Survey Summary provide by class as proof of repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 19 October 2021
Resolved
A vessel equipped with ballast water tanks that operates in the waters of the US must amke a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's ballest water management strategy and comply with the requirements of this subpart.
Vessel's ballast water management plan does not include all of the necessary provisions listed in 33 CFR 151 Subpart D.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 15 November 2021
Resolution: Vessel agent provided revised BWMP showing US requirements and regulations.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 30 September 2016
Resolved
Acceptable types of water seals include the wet and semi-wet type. Other types of seals may be accepted on a case by case basis if approval is given by the Coast Guard Marine Safety Center. Currently the ship is equipped with a double block & bleed, a dry system, and equipped with a fired inert gas system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 January 2017
Resolution: Received copy of Letter from MSC that allows vessel to be fitted with a double block and bleed system.