MAURY USCG vessel records
← All vessels

YM PACIFICO

YM PACIFICO is a 2015 freight ship. The Coast Guard has recorded 13 inspections since 2016, most recently in October 2025, along with 4 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 19 October 2025.

Built
2015
Last inspected
19 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9544102
1337640
Flag
PANAMA
Maury page id
psix-1337640

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it42999 - Convention (Subpart B), Gross Ton
27490 - Convention (Subpart B), Net Ton
81812 - Dead Weight, Metric Ton
94361 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 13

19 October 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8255133
7 October 2025 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8243254
20 February 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7867712
21 December 2022 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7611640
11 December 2022 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7607383
15 September 2022 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7559829
27 March 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7415014
23 March 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7417402
17 January 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7381344
17 January 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7381457
3 January 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6602188
20 December 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6322810
11 May 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5874221

Deficiency record · 4

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 October 2025 Resolved
A self contained emergency source of power shall be provided.PSCO observed that upon starting the EDG there was a malfunction that resulted in an interlock shutdown after about 10 seconds of running due to a lube oil low pressure alarm. Crew was unable to reset the alarm and restart the EDG as a result. 74 SOLAS (20) II/1/43/1.1 60C
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2025
Resolved 8 October 2025
Resolution: Re-verified that the EDG was working properly.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 7 October 2025 Resolved
The condition of the ship and it`s equipment shall be maintained to conform with provisions of the present regulations to ensure the ship in all respect will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed that the indicator panel in the Engine [name withheld] indicated that the Emergency Generator was shown as running after the initial interlock shutdown occured while the generator was in fact shut down and not running. 74 SOLAS (20)I/11 60C
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2025
Resolved 8 October 2025
Resolution: Re-verified that the panel was working properly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2025 Resolved
Electrical services essentail for safety will be ensured under various emergency conditions. PSCO observed 01 inoperable emergency light bulb en route to the free-fall lifeboat. 74SOLAS (20)II-1/40.1.2 10C
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 October 2025
Resolved 7 October 2025
Resolution: Light bulb was rectified on the spot.
14 - Pollution Prevention › 148 - Ballast Water › Extraordinary Condition Claims
Issued 17 January 2022 Resolved
The master, owner, operator, agent, or person in charge of a vessel equiped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel's ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations. 33 CFR 151.2025(a), 40ac.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 February 2024
Resolution: Received Class Report attesting to repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.