Records from 2016 to 2026. Most recent: inspection, 31 January 2026.
Inspection history · 51
31 January 2026
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8304069
11 August 2025
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8207728
2 August 2025
COC-CVE Annual · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8196379
10 October 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8016859
30 May 2024
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7924335
2 May 2024
COC-CVE Annual · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7902782
9 April 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7909030
18 March 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7895581
1 March 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7883617
10 February 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7870639
10 December 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7842555
27 November 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7874700
12 July 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7813078
21 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7763668
21 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7802262
14 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7763332
13 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7791845
17 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7742108
16 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7742110
9 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7734360
8 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7684056
8 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7734367
30 April 2023
COC-CVE Annual · PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7678136
30 April 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7730063
28 February 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7643515
4 January 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616395
28 November 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7600682
13 October 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7576777
24 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542556
9 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529209
1 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7522575
29 July 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7519789
7 July 2022
Ballast Water Examination · PSC A · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7500272
15 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7478744
14 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7477619
21 March 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7415871
9 March 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7408897
28 February 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7403397
23 February 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7400877
29 January 2022
COC-CVE Quarterly · PSC B · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7387487
20 December 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7376185
25 October 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7361399
15 September 2021
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7458524
20 August 2021
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7292528
10 August 2021
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7367425
19 July 2021
Exemption
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7261242
17 July 2021
COC-CVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7252190
5 March 2017
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 6099168
1 November 2016
Construction Oversight
Physical examination · Activities Europe · Activity 6032973
5 August 2016
Construction Oversight
Physical examination · Activities Europe · Activity 5963017
29 April 2016
Plan Review (Other than "T")
Administrative · Activities Europe · Activity 5866930
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 January 2026
Resolved
Where a fixed fire-extinguishing system, not required by this chapter is installed, it shall meet the requirements of the relevant regulations of this chapter and the Fire Safety Systems Code. PSCO observed 44 empty ampules across several decks and main vertical zones, throughout crew and passenger stairwells, corridors, and dining areas. High concentrations of empty ampules were observed in Vista Lounge, backstage Vista Lounge, and Concerto dining creating entirely unprotected areas.
74SOLAS(20) II-2/10.4.1.2
17bc
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2026
Resolved 1 February 2026
Resolution: All empty ampules replaced. Def written as 16bc.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 January 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed combustibles stored in AC room 8.7, and in hydrant locker 16.04.02.
74SOLAS(20) II-2/9.2.2.3.2.2
16bc
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2026
Resolved 31 January 2026
Resolution: Combustibles were removed from each space prior to departing the ship but after paperwork was issued.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 January 2026
Resolved
Where a fixed fire-extinguishing system...is installed, it shall meet the requirements...of this chapter and the Fire Safety Systems Code. PSCO observed 44 empty ampules.
74SOLAS(20) II-2/10.4.1.2
16bc
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2026
Resolved 11 February 2026
Resolution: Internal inspection of all ampules conducted and preventative measures in effect.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 August 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed 04 water mist nozzles with no fluid within the glass activation ampules. One sprinkler head was test broken to ensure there was water flow and the nozzle was still capable of dispersing water as designed. Water did successful disperse. However, it is unknown if the nozzle would properly expand and break in the event of a true fire, making it undetermined on its readily available service. All nozzles that were found in this condition were immediately replaced with new nozzles, and the cause is suspected to be micro-fractures win the bulb itself. 74 SOLAS (09) II-2/14.1.1. Code 07123, Action 17ac (Corrected)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2025
Resolution: Crew replaced empty glass ampules on affected water mist nozzles.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 October 2024
Resolved
A minimum of two two-way radiotelephone apparatus for each fire party for fire-fighter's communication shall be carried on board. Those two-way portable radiotelephones shall be of an explosion-proof type or intrinsically safe.
PSCO observed fire teams equipped with Motorola DP4400e radios. Label states that radio is intrinsically safe when used with Motorolla PMNN4489A. the actual battery in use was found to be Cutrate Batteries P/N M4121H1-A. At the time of exam no objective evidence was available onboard showing the athis battery model maintains the intrinsically safe capability of the radios.
74SOLAS20 II-2/10.10.4 - 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2024
Resolved 23 October 2024
Resolution: Vessel provided proof of new correct radios
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 October 2024
Resolved
Passenger ships carrying more than 36 passengers shall be equipped with automatic sprinkler of an approved type complying with the requirements of the Fire Safety Systmes Code in all control stations, accommodationa nd service spaces, inclusing corridors and stairways. PSCO observed items in rope storage locker number 5002 stacked above the height of the high-pressure water mist nozzles.
74SOLAS20 II-2/10.6.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 October 2024
Resolved 10 October 2024
Resolution: Deficiency corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 May 2024
Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions, shall be kept in good order so as to ensure their required performance if a fire occurs. FSD not operating as designed FSD 11.1.09, 16.7.02, 04.6.01, and 10.1.02. Repaired on site.
74 SOLAS 20 II-2/14.2.1.1.1
10C
Action required: 10 - Deficiency Rectified
Due 2 May 2024
Resolved 2 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 April 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, double-leaf doors equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. FSD 04.5.36 was unable to close due to first double leaf door not latching, preventing the release of the second door. Door was adjusted before departure and closed without issue.
74 SOLAS 20 II-2/9.4.1.1.5.12
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 April 2023
Resolved 30 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 13 July 2022
Resolved
General arangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the... means of access to different compartments. The fire control plan identifies fire screen door 11.6.10 as an "A-Class" self-closing door. However, the door is not fitted with a self-closing mechanism.
SOLAS 04 II-2/15.2.4.1 16ac
SOLAS 04 II-2/15.2.4.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 16 July 2022
Resolution: Received class report attesting to properly installed self-closing device on the FSD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2022
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed multiple extension cords daisy chained together to charge tool batteries and radios in the BOSUN stores on deck 6.
SOLAS 20 II-1/40.1.3 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 July 2022
Resolution: Extension cords were removed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 July 2022
Resolved
Door and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. B-15 door for the deck 12 passenger laundromat did not latch upon closure, preventing the boundary from being maintained.
SOLAS 04 II-2/9.4.1.2.1 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 13 July 2022
Resolution: Crew adjusted FSD and demonstrated the door properly latching.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 January 2022
Resolved
Fire doors in main vertical zones bulkheads, galley boundries and starway enclosures other than power - operated watertight doors and those which are normally locked shall satisfy the follwoing requirements: (1) The door shall be self-closing and capable of closing with an inclination of up to 35 degress.
74 SOLAS (20) II-2/9.4
Fire door FSD 02.6.01 in HFO separator room did not close automatically. Crew adjusted closure and ops tested sat in the presence of the PSCO.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 January 2022
Resolution: Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 January 2022
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release and must no be equipped with any locking device.
74 SOLAS (20) II-2/13
FSD 175.02 in the youth center on deck 17 was found with a locking device. Provide documentation of adequate egress from space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2022
Resolution: FSD 17.5.02 wrongfully had exit sign when door is not designated exit door per fire control plan. Signage removed and relocated to lobby door per fire control plan.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 July 2021
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall close in no less than 40s and no more than 10s.
SOLAS 09 II-2/9.4.1.1.4.2
PSCO's discovered the following FSD's that closed in less than 10s: FSD's 15.4.17, 16.6.14, 16.3.14.
Action taken: 16 ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2021
Resolved 1 August 2021
Resolution: Received class report attesting to the rectification of the deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 July 2021
Resolved
A self-contained emergency source of electrical power shall be provided for a period of 36h, emergency lighting in all service and accommodation alleyways, stairways and exits.
SOLAS 09 II-1/42.2.1.3
PSCO discovered multiple designated e-lighting configurations non-operable throughout the vessel.
Action taken: 16 ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2021
Resolved 1 August 2021
Resolution: Received class report attesting to the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 July 2021
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements; the doors shall be self-closing and capable of closing with an angle of inclination of up to 3.5 degrees opposing closure.
74 SOLAS 2009 CONS. II-2/9.4.1.1.4.1
PSCO discovered Fire screen door 01.4.03 handle was damaged and did not fully latch.
Action taken: 10 c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 July 2021
Resolved 17 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2021
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured.
SOLAS 09 II-1/40.1
PSCO discovered exposed wiring in the overhead of the Deck 5 Main Galley due to a missing ballast light.
Action taken: 10 c
Action required: 10 - Deficiency Rectified
Due 17 July 2021
Resolved 17 July 2021