MAURY USCG vessel records Sign in
← All vessels

AZUL

AZUL is a 2014 freight ship. The Coast Guard has recorded 11 inspections since 2015, most recently in December 2024, along with 3 deficiencies and 1 operational control.

Records from 2015 to 2024. Most recent: operational control imposed, 9 December 2024.

Built
2014
Last inspected
9 December 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9726504 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1337758
Flag
PANAMA
—
Maury page id
psix-1337758

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (2015–2024)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it36518 - Convention (Subpart B), Gross Ton
21278 - Convention (Subpart B), Net Ton
63253 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

9 December 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8044871
9 December 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8045513
9 October 2023 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7805612
18 March 2021 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7156306
6 March 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6921694
6 November 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6576039
30 October 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6571048
6 June 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6438154
5 June 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6436067
4 June 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6433846
6 September 2015 Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5237902

Deficiency record · 3

Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 5 June 2018 Resolved
Code 1410: The machinery... shall be of a design and construction adequate for the service for which they are intended. Vessel was unable to maintain operation of the main diesel engine and lost propulsion. 74 SOLAS (2014 Consol.) II-1/26.1 Code 60ac.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 June 2018
Resolution: PSC received satisfactory class report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 4 June 2018 Resolved
Code: 0725. The piping for the distribution of fire-extinguishing medium shall be arranged and discharge nozzles so positioned that a uniform distribution of the medium is obtained. Discovered three pilot tubes sheared on the CO2. SOLAS (14) II-2/10.4.1.1, FSS Code 5.2.1.2.1 Action taken: 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2018
Resolution: IAW Lloyds Register's Class Report (Statement No: LAN1800160/A3, dated 10June2018), the following was completed: The repairs were visually examined, and pressure tested with no leakage found. All found in order. See uploaded report in Documents.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 4 June 2018 Resolved
Code: 1499. The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The ship's incinerator is inoperable. SOLAS (14) I/11(a) Action taken: 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 October 2018
Resolution: Incinerator repaired and approved by class

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.