BERLINDA is a freight ship. The Coast Guard has recorded 7 inspections since 2017, most recently in March 2026, along with 3 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2017 to 2026. Most recent: inspection, 5 March 2026.

Built
Not recorded
Last inspected
5 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9744051 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1337930
Flag
NORWAY
—
Maury page id
psix-1337930

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 4 calendar years (2017–2026)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it63242 - Dead Weight, Metric Ton
75159 - Displacement, Metric Ton
36321 - Convention (Subpart B), Gross Ton
21598 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

5 March 2026 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8320251
4 March 2026 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8320441
25 October 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7814076
8 September 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6797569
16 August 2019 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6785630
13 January 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6070399
6 January 2017 COE-Offshore · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6066828

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 March 2026 Resolved
Fire fighting systems and appliances shall be in good working order and ready for immediate use. The high pressure CO2 pilot line serving the furthest bank of bottles from the door was disconnected. 74 SOLAS(20)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2026
Resolution: Vessel submitted Class report approving temporary repairs with a spare pipe of the same size and material capable of sustaining the system operating pressure and design standards.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 5 March 2026 No resolution recorded
Every ship to which chapter applies shall carry appropriate atmosphere testing instrument. These shall be capable of measuring concentrations of oxygen PSCO observed O2 instruments required annual testing expired in Feb 2026. 74 SOLAS (20)XI-7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 March 2026 Resolved
The main inlet/outlets of ventilation systems shall capable of being closed from the outside the spaces being ventilated. In the emergency Diesel Generator room ventilation was found worn and damaged. 74 SOLAS(20)II-2/5.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 March 2026
Resolution: New gasket was installed on the spot to the satisfaction of Coast Guard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.