MAURY USCG vessel records
← All vessels

YM UTILITY

YM UTILITY is a 2009 public freight. The Coast Guard has recorded 16 inspections since 2016, most recently in September 2024, along with 8 deficiencies and 5 operational controls.

Records from 2016 to 2024. Most recent: inspection, 24 September 2024.

Built
2009
Last inspected
24 September 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 September 2024
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9337470
1337932
Flag
LIBERIA
Maury page id
psix-1337932

Documentation record

Tonnage as PSIX records it90507 - Convention (Subpart B), Gross Ton
55413 - Convention (Subpart B), Net Ton
103614 - Dead Weight, Metric Ton
136840 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

24 September 2024 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8008438
5 March 2024 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7874339
12 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6719295
16 April 2019 ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6663325
6 February 2019 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6619022
15 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6414700
28 April 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6401116
16 August 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6243447
15 August 2017 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6241751
11 August 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6237233
11 August 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6237612
5 August 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6231203
3 April 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6116447
21 February 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6102096
11 January 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6069270
9 June 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5902113

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 April 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed during lowering the rescue boat that the aft davit remained in position after releasing the winch brake. The forward davit arm released normally, followed by the aft davit violently releasing causing the rescue boat to slam against the hull several times. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2019
Resolution: MSU Savannah received class report attesting that the cause of the after davit failure to release was a locking bar not being released.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2019 Resolved
Fire-fighting appliances shall be kept in good working order. Boundary door to the purifier room would not close on its own. 10c
Action required: 10 - Deficiency Rectified
Resolved 16 April 2019
Resolution: Boundary door was adjusted and able to close properly.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 April 2019 Resolved
Fire-fighting appliances shall be readily available for immediate use. Sprinkler head in paint stores had a bucket hanging beneath it from last test on 25MAR2019. 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 12 June 2019
Resolution: See documents for class report.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 16 April 2019 Resolved
Satisfactory means shall be provided for the protection of the crew in getting to an from all other parts used in the necessary work of the ship. Two handrails leading up to the focsle were deteriorated. 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 April 2019
Resolved 12 June 2019
Resolution: See documents for class report.
Engineering › Fuel Oil Service System › Valve
Issued 30 April 2018 Resolved
2535. 50ac. The company and the ship shall comply with the requirements of the ISM Code. The company should establish procedures, plans and instructions, including checklists as appropriate. PSCO observed a wooden block underneath the HFO to purifier QCV. C/E provided record of recent quarterly report showing test of QCV. C/E provided procedures written in Chinese, when PSCO asked C/E he stated it did not address remmovable testing block. SOLAS 74 (09) IX/1.3 ISM code part A-7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2018
Resolution: MSU Savannah received a class report/proper documentation satisfying requirements.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 30 April 2018 Resolved
0750. 10c. The following fire protection systems shall be kept in good order so as th ensure their required performance; structural fire protection including protections of openings. PSCO observed door in galley of Class A boundry not closing completly. Ships crew adjusted door.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 April 2018
Resolved 30 April 2018
Resolution: Corrected on the spot
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 3 April 2017 Resolved
1499: The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. The fresh waster cooling bypass valve is heavily corroded and not being maintained, 74 SOLAS (14), CH 1 / Reg. 11, 40ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 April 2017
Resolution: Received report from Captain along with pictures stating that the O-Rings had been renewed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 3 April 2017 Resolved
9900: Safe operation and servicing of the device so that any discharge meets the applicable requirements of 33CF159.53. Vessel is currently using a "Micro Deodorant" Biological Toilet cleaner, which is not listed in section 4.14.1 of onboard sewage manual, 33CFR159.57(a)(2).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 3 April 2017
Resolution: Spoke with Captain, Chief Engineer and Second Engineer about proper maintenance of system.

Ownership record