MAURY USCG vessel records
← All vessels

MS. NANCY

MS. NANCY is a 2016 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2017, most recently in February 2026, along with 7 deficiencies — 1 with no resolution recorded —.

Records from 2017 to 2026. Most recent: inspection, 3 February 2026.

Built
2016
Last inspected
3 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9772979
WDI5631
1339283
Flag
UNITED STATES
Maury page id
psix-1339283

Inspections, by type

Years with a record 10 calendar years (2017–2026)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)174.4 ft × 31.9 ft × 14.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)174.4 ft × 31.9 ft × 14.0 ft
ITC tonnagegross 495 / net 148
BuilderBREAUX BROTHERS ENT INC · LOREAUVILLE, LA, UNITED STATES · built 2016
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it495 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
148 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

3 February 2026 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8298720
6 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8285221
6 February 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8076017
31 January 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7858460
3 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7840790
24 March 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7656196
26 January 2022 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7385842
23 February 2021 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7144688
11 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110196
17 January 2020 Administrative Inspection · Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6891343
29 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6697764
16 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6338208
8 January 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6335059
1 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6162601

Deficiency record · 7

14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 3 February 2026 No resolution recorded
Each device meet all other safety requirements of the regulations applicable to the type of vessel for which it is certified. Vent pipe from the sewage holding tank had a pin hole in T joint. Per repair plan temporary repair of JB weld with soft patch over weld and crew monitoring will be conducted. Permanent repair will be completed by next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2028
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 March 2023 Resolved
Irrespective of build date, a vessel operating on a coastwise or oceans route must meet 46CFR181.405 and 181.450. Vessel did not have smoke detectors in all accommodation spaces, missing from each berthing area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 21 June 2023
Resolution: Received repair report detailing items installed to bring fire detection panel in compliance with CFRs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 January 2020 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release unit was expired. 46 CFR 185.740(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2020
Resolved 24 January 2020
Resolution: Purchased new hydrostatic release unit for EPIRB.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 January 2020 Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Chart was from Nov2019 with no corrections. Required to be up-to-date. 46 CFR 184.420(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 24 January 2020
Resolution: Purchased new chart dateed 22JAN2020.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2020 Resolved
Each ring life buoy must be marked with Type II retro-reflective material. Two ring buoys had peeled off retro-reflective tape. 46 CFR 185.604(i)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 24 January 2020
Resolution: Purchased new retro-reflective tape for the two ring buoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2020 Resolved
Flexible hose runs must be visible, easily accessible, protected from mechanical damage, and must not penetrate watertight deck or bulkheads. Two nonmetallic flexible hoses for the fuel oil on the generators were chafing against generator equipment. 46 CFR 182.720(e)(3)(ii)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 January 2020
Resolved 24 January 2020
Resolution: Wrapped the nonmetallic flexible hose with chafing gear.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 24 January 2020 Resolved
Oily water separator requires 5 by 8 inches "Discharge of oil Prohibited" placard by the discharge. 33 CFR 155.450
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 24 January 2020
Resolution: Installed placard by the oily water separator and the discharge. Installed lock for the discharge.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.