Records from 2019 to 2020. Most recent: inspection, 9 January 2020.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 December 2019
Resolved
The ship whether new or existing shall carry at least two fireman's outfits complying with the requirements of regulation 14. Only one fireman's outfit had a self contained breathing apparatus.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2019
Resolved 10 December 2019
Resolution: The company provided vessel with two serviceable fire fighting outfits.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 December 2019
Resolved
A fireman's outfit shall consist of an electric safety lamp. Only one fireman's outfit had a safety lamp.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2019
Resolved 10 December 2019
Resolution: Cleared.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 December 2019
Resolved
For each breathing apparatus a fireproof lifeline of sufficient strength shall be provided. The lifeline was wasted and missing means of a snaphook.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2019
Resolved 10 December 2019
Resolution: Cleared.
10 - Safety of Navigation › N/A - No Subsystem › International code of signals-SOLAS
Issued 8 December 2019
Resolved
An illistrated table describing the lifesaving signals shall be readily available. Ship did not have table of lifesaving signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2020
Resolved 9 January 2020
Resolution: PSCO visually observed the new diagram.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 December 2019
Resolved
Each vessel must have simple operating instructions with a block diagram, showing the steering gear changeover procedures. Ship bridge did not have steering block diagram.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2020
Resolved 9 January 2020
Resolution: PSCO visually observed the new steering gear block diagram.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 May 2019
Resolved
Satellite EPIRB shall be annually tested for operational frequencies, coding, and registration. The vessel could not provide evidence of PEIRB test within 12 months. 74 SOLAS (14) IV/15.9.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 30 May 2019
Resolution: The vessel provided attestation the EPIRB was serviced prior to the team departing the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 May 2019
Resolved
For equipment presenting hazards to personnel protective fencing or shielding for the moving parts must be provided. Main engines and main service generator have unshielded moving parts exposed. ILO-147 / PWSA 1233(b).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: The vessel installed machinery guard around engine room rotating machinery.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 May 2019
Resolved
Where “A” Class divisions are pierced for the passage of electric cables arrangements shall be made to ensure fire resistance is not impaired. Main deck diesel generator electric cable pierces Class “A” boundary to engine room. The penetration allows for passage of flame and smoke. 74 SOLAS II-2/23(a).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: The crew filled gaps in the electrical conduit with expansion foam.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 30 May 2019
Resolved
These ships using separate fuel oil to comply with paragraph 4 of this regulation and entering or leaving an emission control area set forth in paragraph 3 of this regulation shall carry a written procedure showing how the changeover procedure is to be done. Emission control area records and low Sulphur fuel over procedures were not in place at the time of exam. The vessel’s IAPP mentions the vessel must comply with regulation 14 of Annex VI. MARPOL Annex VI Regulation 14.6.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2019
Resolution: The company submitted records attesting the vessel is following US Caribbean ECA Regulations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
Each loading arm and each transfer pipe system including each metallic hose, must not leak under static liquid pressure at least 1 ½ times the maximum allowable working pressure. For vessel’s the test must be done annually or as part of the biannual and mid-period inspections. The vessel’s crew did not provide the team with records of the test. Vessel must test bunker line prior to conducting bunkering in the US. 33 CFR 156.170 f (2).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Vessel does not conduct bunkering operations in the USA.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019
Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Light fixture in engine room had exposed wiring. 74 SOLAS Ch. II-1 Reg. 27(a)(i)(1).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: The crew fixed the exposed wiring in the engine room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019
Resolved
A ship must have a oil discharge placard made of durable material fixed in a conspicuous place in each machinery space. The vessel does not have the placard. 33 CFR 155.450(a).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: The crew installed a pollution prevention placard at discharge point.