Records from 1992 to 2026. Most recent: inspection, 13 April 2026.
Documentation record
Registered dimensions (L × B × D)92.4 ft × 30.1 ft × 12.2 ft
Registered tonnagegross 148 / net 101
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDEFOE SHIPBUILDING COMPANY · BAY CITY, MI, UNITED STATES · built 1945
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it148 - Regulatory (Subpart C or D), Gross Ton
101 - Regulatory (Subpart C or D), Net Ton
148 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
13 April 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8346831
10 March 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8317549
27 February 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8085891
19 January 2024
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7841414
22 February 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7640483
27 April 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7439325
8 February 2022
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7397715
24 January 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7386918
13 January 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7120737
16 January 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6884708
24 June 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6724120
15 January 2019
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6610264
27 September 2017
Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6277029
3 May 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4302310
30 April 2012
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4299030
27 March 2012
Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4272220
18 September 2001
Type not recorded
No type recorded · USCGC CUTTYHUNK (WPB 1322) · USCG Northwest District (CGD-NW) · Activity 1523182
10 June 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 46429
14 February 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754226
12 February 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 206146
9 October 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 716339
6 October 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 144397
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2026
Resolved
Propulsion machinery including main engines, reduction gears, shafting, bearings, and electrical equipment and systems must: be maintained to ensure proper operation. Vessel suffered an overheat on the shaft bearing directly behind stuffing box to the point of smoking. Vessel is to provide root cause analysis, repair, and an operational test to the satisfaction of the attending marine inspector prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2026
Resolved 1 July 2026
Resolution: Sea trials conducted, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 27 February 2025
Resolved
The portable fire pump must be self-priming and power-driven.
Portable pump not self-priming; unable to witness adequate firefighting water supply. Demonstrate test prior to commercial ops.
46 CFR 142.325
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 March 2025
Resolved 6 March 2025
Resolution: Witnessed replacement pump operate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2025
Resolved
Lifesaving- Readiness.
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times.
Life rings worn/faded, with some patches of foam exposed. Replace w/in 14 days.
46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 6 March 2025
Resolution: Inspected replaced ring buoys; all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 January 2021
Resolved
Label all watertight doors as required by 46 CFR 144.160 (e).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 21 January 2021
Resolution: Rcvd email with photos of properly labeled watertight doors.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 13 January 2021
Resolved
Label all immersion suits as required by 46 CFR 199.70(c)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 21 January 2021
Resolution: Rcvd email with photos of properly labeled Immersion suits.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 January 2019
Resolved
Main engine & aux generator low lube oil pressure & high cooling water temp. inoperable. Aux. generator low steering fluid level alarms inoperable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 5 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2019
Resolved
Piping for flammable or combustible liquid, seawater cooling, or fire fighting systems must be color coded in accordance with ISO14726:2008(E) standards. Piping system is not color coded IAW the ISO standard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2019
Resolved
Replace 01 lifejacket (faded retro)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 9 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 January 2019
Resolved
All working pressure vessels must have the MAWP indicated by a stamp, nameplate, or other visible means to the crew. Starting air receivers (02) do not have MAWP on the pressure vessels. Porve by NDT or engineering analysis the MAWP and condition of the pressure vessels, stamp or nameplate the vessel, and verify the relief valve settings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 5 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2019
Resolved
The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. Replace the forward hawser rope to wearing condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 9 February 2019