HARRY M is a 1945 towing vessel. The Coast Guard has recorded 22 inspections since 1992, most recently in April 2026, along with 10 deficiencies and 1 casualty investigation in 2012.
Records from 1992 to 2026. Most recent: inspection, 13 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 4 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it148 - Regulatory (Subpart C or D), Gross Ton 101 - Regulatory (Subpart C or D), Net Ton 148 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
22 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2026Resolved
Propulsion machinery including main engines, reduction gears, shafting, bearings, and electrical equipment and systems must: be maintained to ensure proper operation. Vessel suffered an overheat on the shaft bearing directly behind stuffing box to the point of smoking. Vessel is to provide root cause analysis, repair, and an operational test to the satisfaction of the attending marine inspector prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2026
Resolved 1 July 2026
Resolution: Sea trials conducted, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 27 February 2025Resolved
The portable fire pump must be self-priming and power-driven.
Portable pump not self-priming; unable to witness adequate firefighting water supply. Demonstrate test prior to commercial ops.
46 CFR 142.325
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 March 2025
Resolved 6 March 2025
Resolution: Witnessed replacement pump operate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2025Resolved
Lifesaving- Readiness.
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times.
Life rings worn/faded, with some patches of foam exposed. Replace w/in 14 days.
46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 6 March 2025
Resolution: Inspected replaced ring buoys; all sat.
Label all watertight doors as required by 46 CFR 144.160 (e).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 21 January 2021
Resolution: Rcvd email with photos of properly labeled watertight doors.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 13 January 2021Resolved
Label all immersion suits as required by 46 CFR 199.70(c)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 21 January 2021
Resolution: Rcvd email with photos of properly labeled Immersion suits.
Main engine & aux generator low lube oil pressure & high cooling water temp. inoperable. Aux. generator low steering fluid level alarms inoperable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 5 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2019Resolved
Piping for flammable or combustible liquid, seawater cooling, or fire fighting systems must be color coded in accordance with ISO14726:2008(E) standards. Piping system is not color coded IAW the ISO standard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2019Resolved
Replace 01 lifejacket (faded retro)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 9 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 January 2019Resolved
All working pressure vessels must have the MAWP indicated by a stamp, nameplate, or other visible means to the crew. Starting air receivers (02) do not have MAWP on the pressure vessels. Porve by NDT or engineering analysis the MAWP and condition of the pressure vessels, stamp or nameplate the vessel, and verify the relief valve settings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 5 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2019Resolved
The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. Replace the forward hawser rope to wearing condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2019
Resolved 9 February 2019
3 May 2012Routine · role: Involved in a Marine Casualty · activity 4302310
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.