MAURY USCG vessel records
← All vessels

MISS GINGER

MISS GINGER is a 1975 towing vessel. The Coast Guard has recorded 14 inspections since 1998, most recently in December 2025, along with 8 deficiencies.

Records from 1998 to 2025. Most recent: inspection, 9 December 2025.

Built
1975
Last inspected
9 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 9 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (1998–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCP9775
134229
Flag
UNITED STATES
Maury page id
psix-134229

Documentation record

Registered dimensions (L × B × D)58.3 ft × 24.1 ft × 9.1 ft
Registered tonnagegross 85 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderP & S MARINE BLDGS & REP · MOBILE, AL, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Simplified, Gross Ton
68 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

9 December 2025 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8279807
3 November 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8262432
27 May 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8145442
18 January 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8065230
28 November 2023 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7830441
13 February 2023 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7623751
8 February 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7384605
22 June 2020 MTSA Verification · Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6992346
13 July 2011 Deficiency Check · Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4086157
11 October 2006 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2798756
18 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2752204
30 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2408847
7 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2304988
13 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 175338

Deficiency record · 8

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The STBD Generator is not operational. Conduct adequate repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 March 2022
Resolution: Received video and picture evidence of operational starboard generator.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 February 2022 Resolved
The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed. Watertight doors have damaged gaskets and multiple dogs are inoperable. The forward STBD deck hatch is not watertight. The base of the port side superstructure bulkheads are wasted through. Conduct adequate repairs insuring structural watertight integrity to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 March 2022
Resolution: Received evidence of all items corrected
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. There was excessive oil in the bilge, remove prior to departing to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 March 2022
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 8 February 2022 Resolved
Be designed to prevent the overboard discharge of treated or untreated sewage or any waste derived from sewage (Type III). MSD had no valve to prevent overboard discharge, repair to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 March 2022
Resolution: Valve installed to prevent ovbd discharge
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The breaker in the engine room had open slots and was unable to be closed. The switchboard in the engine room had water leaking directly onto it. The electrical boxes on the stern were broken and not watertight. The circuit breakers were not properly labeled. The Repair to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 March 2022
Resolution: Received evidence of all items corrected. Source of water leak to switchboard identified and fixed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 February 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Excess dirt and oil on steering pumps and on exhaust vents on the stern. Remove excess dirt and oil to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2022 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation. Port and STBD engines had oil leaks, repair to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 8 February 2022 Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. This includes machinery, deck machinery, towing gear, ladders, embarkation devices, cranes, portable tools, and safety equipment. The pressure relief valve for the hot water tank should be piped into the bilge. Repair to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 March 2022

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.