Records from 2016 to 2024. Most recent: inspection, 25 November 2024.
Inspection history · 33
25 November 2024
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8038517
21 May 2024
PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7914180
20 November 2023
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7826957
15 June 2023
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7715539
15 May 2023
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7687239
7 November 2022
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7589582
2 May 2022
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7439089
25 October 2021
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7337620
27 April 2021
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7183617
26 April 2021
Ballast Water Examination · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7180797
20 October 2020
PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7080004
20 April 2020
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6940318
28 October 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6856193
14 October 2019
ISPS III Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6833832
16 May 2019
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6685632
28 March 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6649507
10 October 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6557520
27 September 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6549765
10 September 2018
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6537101
9 July 2018
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6472625
3 July 2018
PII Safety Exam · ISM Exam · Ballast Water Examination · ISPS III Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6459755
30 December 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6330546
21 July 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6216818
19 July 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6214013
11 July 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6205647
10 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6121238
29 December 2016
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6062643
28 December 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6062078
11 August 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6052318
8 July 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5934216
27 June 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5915728
19 April 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5855928
4 April 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5847230
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 15 May 2023
Resolved
Every ship of 400 GT and above shall carry a garbage managemnt plan in accordance with the guidelines developed by the Organization. Last approved garbage management plan is from 2009 and does not address new IMO guidelines.
MARPOL V/9
IMO IA656E
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 15 June 2023
Resolution: New edition of Garbage Management Plan dated 16MAY23 addresses new IMO guidelines.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 May 2023
Resolved
Liferaft painter system shall be arranged to ensure that the liferaft when released is not dragged under by the sinking ship. Liferaft painter was improperly arranged.
74 SOLAS (97) III/38.6.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 May 2023
Resolved 15 May 2023
Resolution: Vessel crew properly arranged the liferaft painter.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 April 2021
Resolved
Suitable instructions and component spares for testing shall be provided to test fixed fire detection system. No spare smoke testing cannisters on board at time of inspection.
74 SOLAS (97) II-2/13.1.12
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 10 May 2021
Resolved 27 April 2021
Resolution: PSCO Verified testing cannisters on board vessel and witnessed satisfactory test of fire alarm in engine room.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 14 October 2019
Resolved
Except as specified in paragraph 3 of this regulation, any ship of 400 gross tonnage and above but less than 10,000 gross tonnage shall be fitted with oil filtering equipment complying with paragraph 6 of this reg. The OWS cannot display the requirement for 15 ppm and under. MARPOL ANNEX I CH 3.1/REG14
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2019
Resolved 28 October 2019
Resolution: Received Tech Report of testing for the Oil Content Meter.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 14 October 2019
Resolved
Each ballast water management system (BWMS) manufactured under Coast Guard approval must have a nameplate which is securely fastened to the BWMS and plainly marked by the manufacturer with the information listed in paragraph (b) of this section. The BWMS does not have the approval nameplate.
46CFR162.060-22
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2019
Resolved 15 October 2019
Resolution: Received a photograph of new placard attached to the BWTS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 September 2018
Resolved
The fire resistance of doors shall be equivalent to that of the division to which they are fitted. The PSC team noted missing class "b" door in the crew's mess located on "A" deck. 74SOLAS(97)II-2/47.1; 14 days to satisfaction of CG
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 10 October 2018
Resolution: Class "B" door installed to the Crew's mess. All sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 July 2018
Resolved
Multiple SMS non-conformities were observed and documented following an expanded ISM exam. An external audit was recommended. See Form B for details.
Action required: 30 - Ship detained
Resolved 4 July 2018
Resolution: Class performed an external audit and provided a corrective action plan.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 3 July 2018
Resolved
After any survey of the ship under regulations 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The MSD is not operating as originally certified. The crew has created an unauthorized modification to the MSD by arranging for the grey water produced by the unapproved installation of a workshop air conditioning unit to drain into an open-top 55-gallon barrel via a flexible hose, which is connected by way of another flexible hose to the MSD’s vent hard pipe. The bilge well has thick oily residue from prior use as storage for oily waste, which creates a fire hazard and is an unsafe practice not authorized by the IOPP. The steering gear room was found without nonslip surfaces required in the event of an oil spill.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2018
Resolution: Verified deficiencies corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 July 2018
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids and means shall be provided to limit the accumulation of flammable vapours. The bilge was coated in a thick oily residue on the structural members and frames forming the bilge wells creating a significant fire hazard.
Action required: 30 - Ship detained
Resolved 4 July 2018
Resolution: Verified bilge was cleaned and cleared the deficiency.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 3 July 2018
Resolved
*DEFICIENCY WRITTEN TO 33 CFR* No person may operate any vessel with installed toilet facilities unless it is equipped with an operable Type I or Type II device that has a label on it under 159.16 or that is certified under 159.12 or 159.12(a). A strong pungent odor and statement by the chief engineer the vent pipe is clogged indicates there is an issue with the MSD not operating as initially certified.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2018
Resolution: Cropping and renewing the pipe into which the unauthorized grey water connection joined the MSD piping appeared to resolve the smell and the Class surveyor attested to the MSD's operation thereafter. Deficiency cleared.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 3 July 2018
Resolved
*DEFICIENCY WRITTEN TO 33 CFR* When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the EPA under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. The MSD skin valve was not secured in any way to prevent discharge of sewage. The chief engineer stated the MSD discharges automatically when the volume of sewage level reaches a set point regardless of where the vessel is, in port or not, and the overboard has not been properly secured in years.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2018
Resolution: The chief engineer placed a chain and padlock on the MSD overboard valve.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 3 July 2018
Resolved
The steering gear compartments shall be: provided with suitable arrangements to ensure working access to steering gear machinery and controls. These arrangements shall include gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. The steering gear compartment deck is bare steel and is not covered with gratings or nonslip surfaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 13 July 2018
Resolution: Verified deficiency corrected.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 3 July 2018
Resolved
In all ships general arrangement plans shall be permanently exhibited for the guidance of the ship’s officers, showing clearly for each deck the fire detection and fire alarm systems. The fire control plan indicates the vessel was built to method IC which requires smoke detection and manually operated call points in all corridors, stairways and escape routes within accommodation spaces (74 SOLAS 97 II-2/52.1). The fire control plan does not indicate where any smoke detectors should be installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 13 July 2018
Resolution: Verified deficiency corrected.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 3 July 2018
Resolved
All ships of 150 gross tonnage and upwards in addition to the requirements of paragraph 2.1, be fitted with: a daylight signally lamp, or other means, to communicate by light during day and night using an energy source of electrical power not solely dependent upon the ship’s power supply. The crew stated the daylight signalling lamp does not have a secondary source of power in accordance with IMO Resolution MSC.95(72)7.3.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 13 July 2018
Resolution: Verified deficiency corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 July 2018
Resolved
A Vessel General Permit (VGP) provides National Pollutant Discharge Elimination System (NPDES) permit coverage for discharges incidental to the normal operation of all non-recreational vessels of 79 feet or greater in length while operating in U.S. waters. This permit is effective from December 19, 2013 to December 18, 2018 (i.e., five years). The vessel has a valid NPDES permit, but the crew could not locate the VGP and were unfamiliar with its contents, such as incidental discharges and visual inspections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 13 July 2018
Resolution: Verified deficiency corrected.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 29 December 2016
Resolved
0690 - Before a ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO observed that all 4 rockets for the line throwing appliance expired in November of 2016. - SOLAS 74 (cons) III/20
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 5 January 2017
Resolution: Vessel submitted evidence showing receipt of new rockets on board.
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 27 June 2016
Resolved
A second source of energy shall be provided for an additional three starts whithin 30 minutes unless namual starting can be demonstrated to be effective. PSCO found that the emergency generator's second means of starting, using a match and film, was inoperable.
74SOLAS(04) II-1/44.2. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2016
Resolved 29 June 2016
Resolution: Ships crew were able to install a second set of batteries, with its own charging unit, enabling emergency generator to possess two means of starting.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 June 2016
Resolved
Posters or signs shall be provided on, or in the vicinity of survival craft and their launching controls. PSCO found that the lifeboats operating and launching instructions were missing from the embarkation station. 74SOLAS(14) III/9.2. 16ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2016
Resolved 29 June 2016
Resolution: Operating and launching instructions for the lifeboat were replaced and posted properly by ships crew.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 27 June 2016
Resolved
Simple Operating instructions with block diagram showing the change over procedures shall be permanently displayed on the navigation bridge. PSCO found that thre were no instructions for operation of remote steering gear control systems and power units or block diagrams.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 July 2016
Resolved 8 July 2016
Resolution: Vessel Master provided a Class Report attesting to the correct placement of the chart for Steering Gear Changeover Procedures.
Lifesaving › Inflatable Liferafts › Float Free
Issued 27 June 2016
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order. PSCO found the starboard liferaft cradle to be wasted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 June 2016
Resolution: Ships crew repaired cradle for the starboard liferaft to the satisfaction of attending Coast Guard Inspector.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 27 June 2016
Resolved
The Ballast water management plan must include detailed fouling maintenance and sediment removal procedures. PSCO found no fouling maintenance procedures. 33CFR151.2050(g)(3). 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 8 July 2016
Resolution: Received proper documentation attesting to the presence of an Anti-Fouling Plan within the ships BWM Plan.
Fire Fighting › Firemans Outfit › Lifeline
Issued 27 June 2016
Resolved
For Each breating apparatus a fireproof line of sufficient length and strength shall be provided capable of being attached by means of a snaphook. PSCO found there to be no fireproof line with snaphook.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 July 2016
Resolved 29 June 2016
Resolution: PSCO observed proper lifelines for Firemans outfits placed into service.
Navigation › Piloting/Steering › Gyro Compass
Issued 4 April 2016
Resolved
Gyro compass reported inoperative on letter of deviation request.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2016
Resolved 17 April 2016
Resolution: Vessel submitted technican's service repot stating the gyrocompass is fully oparational