Records from 2016 to 2025. Most recent: inspection, 25 November 2025.
Inspection history · 18
25 November 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8211515
27 October 2025
Internal Structural Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8210893
21 November 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7987887
20 November 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7828484
13 November 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7799539
5 January 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7558132
25 January 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7385383
27 October 2021
Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7341046
12 November 2020
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7094329
3 November 2020
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7081254
15 October 2019
Internal Structural Exam · Annual Inspection · Hull Examination · Administrative Inspection · Drydock Exam · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6834930
26 November 2018
Deficiency Check · Annual Inspection · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6575170
24 October 2017
Administrative Inspection · Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6304390
23 January 2017
Administrative Inspection · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6075777
9 September 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5999313
4 May 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5868989
22 March 2016
Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5830780
27 January 2016
Inclining Experiment · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5809929
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 13 November 2023
Resolved
Paragraphs (c) through (g) of this section apply to each vessel that does not demonstrate compliance in accordance with § 178.310(c) of this chapter. Each vessel must-have permanent draft marks at each end of the vessel; or
have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. Vessel missing draft and/or loading marks. Permanently affix draft or loading marks to the vessel's hull at next dry dock to the satisfaction of the attending MI.
46 CFR 185.602(b)(c)
Action required: 705 - Other - as specified
Due 20 November 2023
Resolved 20 November 2023
Resolution: Vessel rep used tap to permanently imprint load marks onto vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 January 2022
Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces. Life jackets stowed below deck in hull of vessel. Each life jacket must be readily available; make readily available to the satisfaction of the attending MI.
46 CFR 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2022
Resolution: Each life jacket was made readily available and stowed below seating. Vessel has made readily available to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 January 2022
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Ensure life jacket markings are revised after complying with deficiency #1 above to the satisfaction of the attending MI.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2022
Resolved 7 February 2022
Resolution: Container for life jackets was marked after relocating.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 January 2022
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. The solenoid on the port side of the tank room is affixed to the vessel structure with wire ties. Permanently mount to vessel structure to the satisfaction of the attending MI.
46 CFR 183.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2022
Resolved 7 February 2022
Resolution: Replaceed with new covered/enclosed solenoid.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 January 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to:(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts. Dual power post cable connector terminals for battery charger amp meter positive terminals exposed. Cover terminals to the satisfaction of the attending MI.
46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2022
Resolved 26 January 2022
Resolution: Covered terminals to the satisfaction of the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 January 2022
Resolved
Each vessel must be equipment with at least two operable portable battery lights. Vessels second portable battery light inoperable needs replacement battery.
46 CFR 183.200(b)(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2022
Resolved 25 January 2022
Resolution: Replaced battery in flashlight.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 January 2022
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel did not have Aspirin in the first aid kit.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2022
Resolved 25 January 2022
Resolution: Purchased and placed aspirin in Medical kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2021
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. According to part 2.4.1 in the manufacturers specifications the vessels aluminum keel coolers "should be installed on unpainted aluminum hulls only". The vessels hull is painted and therefore the installation is not in compliance with the manufactures specifications. Provide documentation from the manufacture attesting to the authorized use of the aluminum keel coolers on a painted hull to be reviewed and approved by the attending USCG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2021
Resolved 22 April 2022
Resolution: COI amended to reflect annual drydock schedule to monitor keel cooler.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 November 2020
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent extent necessary to determine that they are in suitable condition and fit for the service intended.
MI observed the starboard rudder post nitrile lip seal weeping. Replace during 0ct 2021 dry dock.
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 15 November 2021
Resolution: Rudder lip seal installed. No weeping observed during sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 November 2018
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating; Vessel does not have visual indicators for bilge pump. Provide visual indicators
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 December 2018
Resolution: MI verified proper operation.
Construction/Loadline › Hull › Hull Plating
Issued 9 November 2017
Resolved
Weld top forward side of collision bulkhead IAW Lloyds special craft rules. CH 13 section 3.4.6 (2010) requires that welding is to be double continuous fillet welding or full penetration welding.
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 6 December 2017
Resolution: Forward top side of collision bulkhead welded to satisfaction of MI.
Electrical › Electric Supply System (service) › Battery Charger
Issued 23 January 2017
Resolved
Digital mobile charger on starboard side does not have an ammeter in charging circuit. Provide battery charger with an ammeter in the charge circuit. 46 CFR 183.350(f)
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 7 March 2017
Resolution: Received photo of ammeter installed in the charging circuit.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 23 January 2017
Resolved
Positive cables from batter switch to starters are rubbing against frames. Install chafing gear under cables where it is touching a frame. 46 CFR 183.200; 46 CFR 176.830(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 21 February 2017
Resolution: Chafing gear installed where battery cables touched frames.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 23 January 2017
Resolved
Flexible nonmetallic hose used for fuel fill does not have a grounding strap. Install grounding strap between metallic sections of the fill pipe to protect against buildup of static charge. 46 CFR 182.445(g)
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 31 January 2017
Resolution: Received photograph of grounding strap installed.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 23 January 2017
Resolved
Blade type fuses installed in stereo, sounder, and multiple displays. Remove blade type fuses and install cartridge type fuses in circuit that are UL listed. 46 CFR 183.380(l)
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 25 October 2017
Resolution: Verified installation of UL listed cartridge type fuses.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 23 January 2017
Resolved
Holes found in collision bulkhead. Fill holes in collision bulkhead with caulking/fire stop as a temporary repair.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 31 January 2017
Resolution: Received photo of holes filled with fire stop.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 March 2016
Resolved
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 March 2016
Resolved
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2016
Documentation › Certificates/Documents › FCC SSL
Issued 22 March 2016
Resolved
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2016