BORAQ is a 2003 tank ship. The Coast Guard has recorded 6 inspections since 2016, most recently in March 2017, along with 3 deficiencies and 2 operational controls.
Records from 2016 to 2017. Most recent: inspection, 16 March 2017.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it46285 - Dead Weight, Ton 56235 - Displacement, Ton 12063 - Convention (Subpart B), Net Ton 29576 - Regulatory (Subpart C or D), Gross Ton 12063 - Regulatory (Subpart C or D), Net Ton 29576 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 6
16 March 2017Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6102983
18 March 2016Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5835815
4 February 2016Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5809739
3 February 2016Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808559
29 January 2016Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5806048
26 January 2016Deficiency Check · COC-CHEM & TVE Renew · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5803076
1899- The inert gas system shall be capable of inerting and maintaining the atmosphere in any part of any cargo tank with an oxygen content not exceeding 8% by volume. The IGS oxygen content is not able to produce and maintain below 8% oxygen. SOLAS 01 CH. II-2 Reg 62.2.2 (10c)
Due 26 January 2016
Resolved 26 January 2016
Resolution: Corrected on the spot.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 26 January 2016Resolved
1721- Oil sludge residue may be disposed of directly from the oil residue tanks through standard discharge connection. The oil residue tanks shall be provided with a designated pump for disposal that is capable of taking suction from oil residue tank. The sludge pump is inoperable. MARPOL II ANNEX 1 Reg. 12.2.1 (16ac)
Action required: 705 - Other - as specified
Due 9 February 2016
Resolved 18 March 2016
Resolution: Received classification report attesting to repairs
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 26 January 2016Resolved
2199- No person may operate any vessel equipped with toilet facilities unless it is equipped with an operable type II or type III device. The MSD has pin holes on top of device, sewage-tank. 33CFR159.7 (40c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 March 2016
Resolution: Received classification report attesting to repairs
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.