MAURY USCG vessel records
← All vessels

BELGRANO

BELGRANO is a freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in February 2025, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 25 February 2025.

Built
Not recorded
Last inspected
25 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 February 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9708992
1344121
Flag
MARSHALL ISLANDS
Maury page id
psix-1344121

Documentation record

Tonnage as PSIX records it43028 - Dead Weight, Metric Ton
27444 - Displacement, Metric Ton
27444 - Convention (Subpart B), Net Ton
43028 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

25 February 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8084149
14 February 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8079930
20 December 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8049726
6 December 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7107010
20 November 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6583333
20 November 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6307460
1 August 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5959722
29 July 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5951246

Deficiency record · 5

14 - Pollution Prevention › 148 - Ballast Water › Extraordinary Condition Claims
Issued 20 December 2024 Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations. 33 CFR 151.2025(a). Action Code: 40c.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 December 2025
Resolved 14 February 2025
Resolution: Sector VA PSS received BWMC issued by NKK on 06FEB25 attesting to proper operation of vessel's BWTS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 November 2018 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. TWO 100LB CO2 CYLINDERS LOCATED IN CO2 ROOM SHOW SIGNIFICANT CORROSION ON CYLINDER HEADS AND ASSOCIATED FITTINGS. 74SOLAS(2014)II-2/14.2.1.2 30ABC
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2018
Resolved 21 November 2018
Resolution: Received class report and photographic evidence of resolution.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2018 Resolved
EVERY STEAM PIPE AND EVERY FITTING CONNECTED THERETO THROUGH WHICH STEAM MAY PASS SHALL BE SO DESIGNED, CONSTRUCTED AND INSTALLED AS TO WITHSTAND THE MAXIMUM WORKING STRESSES TO WHICH IT MAY BE SUBJECTED. A STEAM LEAK WAS DISCOVERED IN ENGINE ROOM USED TO HEAT FUEL. 74SOLAS(2014) II-1/33.1 10C
Action required: 10 - Deficiency Rectified
Due 20 November 2018
Resolved 20 November 2018
Resolution: Corrected on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2018 Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES, AND OTHER HAZARDS. A DIESEL FUEL LEAK, ONE DROP EVERY TWO SECONDS, WAS DISCOVERED ON FUEL FILTER LOCATED ON FUEL BOOSTER PUMP #2 NEXT TO SERVICE GENERATOR. 74SOLAS(2014) II-1/26.1 10c
Action required: 10 - Deficiency Rectified
Due 20 November 2018
Resolved 20 November 2018
Resolution: Corrected on the spot
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 November 2018 Resolved
SUCH CERTIFICATES, IF VALID, SHALL BE ACCEPTED UNLESS THERE ARE CLEAR GROUNDS FOR BELIEVING THAT THE CONDITION OF THE SHIP OR OF ITS EQUIPMENT DOES NOT CORRESPOND SUBSTANTIALLY WITH THE PARTICULARS OF ANY OF THE CERTIFICATES OR THAT THE SHIP AND ITS EQUIPMENT ARE NOT IN COMPLIANCE WITH THE PROVISIONS OF REGULATION 11(A) AND (B). OBJECTIVE EVIDENCE DURING AN EXPANDED ISM EXAM REVEALED THAT THE CREW DID NOT IDENTIFY THE CORRODED CYLINDER HEADS DURING THEIR MONTHLY CHECKS, WHICH RESULTED IN A SYSTEMIC LACK OF MAINTENENCE OF CRITICAL SYSTEMS AS IDENTIFIED IN THE SHIP'S SAFETY MANAGEMENT SYSTEM (SMS). RECOMMEND AUDIT OF SHIP'S SMS CONCERNING FIXED CO2 SYSTEM INSPECTION PROCEDURES. 74SOLAS(2014) I/19(B) 30ABC OBJECTIVE EVIDENCE DURING AN EXPANDED ISM EXAM REVEALED THAT THE CREW DID NOT IDENTIFY THE CORRODED CYLINDER HEADS DURING THEIR MONTHLY CHECKS. RECOMMEND AUDIT OF SHIPS SAFETY MANAGEMENT SYSTEM CONCERNING FIXED CO2 SYSTEM INSPECTION PROCEDURES. 74SOLAS(2014) I/19(B) 30ABC
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2018
Resolved 21 November 2018
Resolution: Received class report

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.