Records from 2016 to 2026. Most recent: inspection, 31 July 2026.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 15.0 ft × 7.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAUX BOATBUILDER INC · GEORGETOWN DE, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPUT-IN-BAY, OH
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 29 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Net Ton
29 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
31 July 2026
Administrative Inspection · Plan Review "T" Boat · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8451343
7 November 2025
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8265827
17 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8188198
17 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8044879
1 November 2023
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7819457
21 October 2022
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7581546
3 November 2021
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7345238
22 October 2020
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7082487
2 December 2019
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6944357
14 November 2019
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6856218
2 November 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6574650
9 July 2018
Inclining Experiment
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6477743
1 November 2017
Annual Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6298234
28 September 2017
Plan Review "T" Boat
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6276897
18 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6244548
25 October 2016
Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6029894
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 November 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:
(1) A light to indicate discharge;
(2) An audible alarm that sounds upon discharge. MI found Fire Boy systems helm visual and audible alarm to be intermittent.
46 CFR 181.420(b)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2026
Resolution: Photo and video of new fireboy helm monitor alarm and visual indication
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 November 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI found penetrations in water tight bulkhead were not sealed. 46 CFR 179.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2026
Resolution: Vessel used 4200 silicone for tubings/fittings and 5200 silicone for bulkhead penetrations. MAterial condition sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 November 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI found electrical wiring in collision bulkhead not sealed. 46 CFR 179.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2026
Resolution: All sat.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 11 November 2025
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. MI found compass light out. 46 CFR 184.402(c)
Limited to daytime operations
Action required: 705 - Other - as specified
Resolved 30 July 2026
Resolution: Photo of installed light
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 11 November 2025
Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. MI found spacers missing. 46 CFR 180.137(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 July 2026
Resolution: Photo of larger spacers recieved
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 November 2025
Resolved
This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI found generator's belt inoperable during operation. Effect repairs prior to use.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 August 2026
Resolution: New generator installed. Plan review conducted by [name withheld] condition matched drawings and plans provided.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 August 2017
Resolved
A vessel of not more than 65 feet in length must have a collision bulkhead if it: is more than 40 ft in length and operates on partially protected waters. 46CFR179.212
Install a collision bulkhead that meets the requirements of 46CFR179.310 and 179.320
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 2 November 2018