MAURY USCG vessel records
← All vessels

SEAWAYS LOOKOUT

SEAWAYS LOOKOUT is a 2015 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in August 2026, along with 6 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 18 August 2026.

Built
2015
Last inspected
18 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 August 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9700342
1345338
Flag
LIBERIA
Maury page id
psix-1345338

Documentation record

Tonnage as PSIX records it60736 - Displacement, Metric Ton
13781 - Convention (Subpart B), Net Ton
29770 - Convention (Subpart B), Gross Ton
50136 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

18 August 2026 Administrative Inspection · COC-CHEM & TVE Annual
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8467523
26 June 2025 COC-CHEM & TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8167999
29 December 2023 COC-CHEM Annual
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7843212
6 November 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7821085
7 December 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7605605
4 May 2022 Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7443720
15 January 2022 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7377759
1 December 2020 PSC B · COC-CHEM Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7102725
1 December 2020 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7104275
22 March 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6645088
1 October 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6552344
30 December 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6331320
27 November 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6044489
4 February 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5809700

Deficiency record · 6

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 June 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO discovered a zip-tie over the sensor above the suction line valve for Power Pack #4, which provided faulty position indication in contrast with its design. Sensor was replaced and found in satisfactory operation. 74 SOLAS (20), I/ll(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 July 2025
Resolved 3 July 2025
Resolution: Ship's crew removed zip tie and replaced sensor restoring proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 November 2023 Resolved
Under all sailing conditions, including maneuvering, the speed, direction of thrust and, if applicable, the pitch of the propeller shall be fully controllable from the navigation bridge. Due to failure of the main engine unit #1 full control module, bridge control of the main engine was lost and was given to local control from the engine control room.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 November 2023
Resolution: ABS Class report received.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 4 May 2022 Resolved
Vessel self-reported an inoperable ballast water treatment system.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 December 2022
Resolution: Vessel provided Flag dispansation attesting to the repair of the BWMS. Doc uploaded in Doc tab.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 March 2019 Resolved
07123: The venting system shall be provided with devices to prevent th. passage of flame into cargo tanks. Vessels pressure/vacuum breaker did not have a flame screen meeting MSC/Circ. 677. Provide clarification from RO/RSO to proper design of P/V breaker flame screen prior to loading flammable cargo SOLAS 74a (09) II-2/4.5.3.3 a,c
Action required: 705 - Other - as specified
Resolved 26 March 2019
Resolution: Received, reviewed and accepted class report from ABS. Class reviwed drawing and arrangements and confirmed proper flame screen.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 March 2019 Resolved
04109Fire drills should be planned in such a way that due consideration is given to regular practice in various emergencies that may occur depending on the type of ship and cargo carried.PSCO observed that the last 3 fire drill were conducted with the exact same time line on drill card. Ships crew completed satisfactory drill on STBD manifold. SOLAS 74a (09) III/19.3.4 10c
Action required: 10 - Deficiency Rectified
Due 22 March 2019
Resolved 22 March 2019
Resolution: Ships crew completed satisfactory drill on STBD manifold
Lifesaving › Lifeboat Equipment › Food Ration
Issued 27 November 2016 Resolved
0611-Lifeboat Inventory-All life-saving appliances & arrangements shall comply with the applicable requirements of the LSA Code. Every lifeboat shall consist of a food ration totaling not less than 10,000 kJ for each person the lifeboat accommodates. PSCO observed only 28 food rations in the 32-person port lifeboat kept in airtight packaging. 74 SOLAS (14) III/34, LSA Code 4.4.8.12 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 27 November 2016
Resolved 30 November 2016
Resolution: Received proper documentation from vessel's master stating all outstanding deficiencies have been rectified. The proper documentation stated: 06 USCG/SOLAS approved lifeboat rations were received onboard the vessel on 30NOV16.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.