Records in 2023. Most recent: inspection, 4 August 2023.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 August 2023
No resolution recorded
Oil fuel pipes which if damaged would allow oil to escape from a storage tank 500L and above shall be fitted with cock or valve at tank capable of being closed from outside space in the event of fire occurring in space in which tanks located. All fuel tank remote shut off valves for engine room are inoperative. Repair and or provide mitigation plan. SOLAS 74(2020)II-2/4.2.2.3.4, 17BC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 August 2023
No resolution recorded
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and alarm systems. Smoke and heat detectors found inoperative in engine room. Repair and or provide mitigation plan. SOLAS 74(2020)II-2/14.2.1.1.2, 17BC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 4 August 2023
No resolution recorded
Any ship 400GT and above but less than 10,000GT shall be fitted with oil filtering equipment complying with paragraph 6 of this regulation. Oily water separator inoperative and has missing piping. Repair and or provide mitigation plan. MARPOL I/14.1, 17BC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 4 August 2023
No resolution recorded
Main and auxiliary steering power units shall be: In the event of a power failure to any one of the steering gear power units, an audible and visual alarm shall be given on the navigation bridge. Steering gear loss of power alarm inoperative. Repair and or provide mitigation plan. SOLAS 74(2020)II-2/29.5.2, 17BC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 4 August 2023
No resolution recorded
Hydraulic power-operated steering gear shall be provided with the following: a low level alarm for each hydraulic fluid reservoir to give earliest indication of fluid leakage. Audible and visual alarm on navigation and machinery space. Steering gear low-level alarms inoperative. Repair and or provide mitigation plan. SOLAS 74(2020)II-1/29.12.2, 17BC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 August 2023
No resolution recorded
Where the bilge pumps are being started automatically means shall be provided to indicate when the influx of liquid is greater than the pump capacity. Bilge alarms inoperative in engine room. Repair and or provide mitigation plan. SOLAS 74(2020)II-1/48.2, 17BC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 August 2023
No resolution recorded
Nautical charts and nautical publication, such as sailing directions, list of light, notices to mariners, tide tables and all other nautical publications necessary for the intended voyage shall be adequate and up to date. Nautical charts and publication are not up to date. Acquire updated charts and publications. SOLAS 74(2020)V/27, 40C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2023
No resolution recorded
Main and emergency switchboards, where necessary non-conducting mats or gratings shall be provided at the front and rear of the switchboard. SOLAS 74(2020)II-1/45.2, 40C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 4 August 2023
Resolved
The purpose of this regulation is to provide means of escape to the lifeboat and life raft embarkation deck. For this purpose, the following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. Galley means of escape obstructed. Removed obstructions. SOLAS 74(2020)II-2/13.1.2, 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 August 2023
Resolution: Removed obstruction while inspector on board.