HAFNIA ARONALDO is a 2015 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in March 2026, along with 2 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 6 March 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it23676 - Convention (Subpart B), Gross Ton 10252 - Convention (Subpart B), Net Ton 38506 - Dead Weight, Metric Ton 46596 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 16
6 March 2026PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8311717
30 January 2025PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8067648
13 August 2023In-Service Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7767558
9 July 2023Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7737195
29 January 2023COC-CHEM Renew · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7626208
2 November 2021Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7343714
11 October 2021PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7330439
5 September 2020MARPOL Annex VI Survey · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7050719
2 September 2020Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7048384
18 June 2019ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6708457
27 December 2017COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6327531
THE MEANS FOR SECURING THESE DOORS WEATHERTIGHT SHALL CONSIST OF GASKETS AND CLAMPING DEVICES OR OTHER EQUIVALENT MEANS AND SHALL BE PERMANENTLY ATTACHED TO THE BULKHEAD OR TO THE DOORS THEMSELVES, AND THE DOORS SHALL BE ARRANGED SO THEY CAN BE OPERATED FROM BOTH SIDES OF THE BULKHEAD.
PSCO OBSERVED BROKEN WEATHERTIGHT DOOR ON THE NITROGEN GENERATOR SPACE.
ICLL (66)/ REG. 12
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 March 2026
Resolved 12 March 2026
Resolution: Vessel provided pictures with class survey attesting to the fixing of the door.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 24 July 2017Resolved
Vessel's ballast water management plan does not include all the necessary provisions listed in 33 CFR 151 Subpart D. (see activity # 6213805 for full text of deficiency) (33 CFR 151.2050 (g)) (40c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 July 2017
Resolved 3 August 2017
Resolution: Vessel submitted documentation satisfying deficiency.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.