MAURY USCG vessel records Sign in
← All vessels

AFRICAN TEAL

AFRICAN TEAL is a 2015 freight ship. The Coast Guard has recorded 11 inspections since 2015, most recently in June 2026, along with 7 deficiencies and 1 operational control.

Records from 2015 to 2026. Most recent: inspection, 18 June 2026.

Built
2015
Last inspected
18 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9691046 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1345987
Flag
PANAMA
—
Maury page id
psix-1345987

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2015–2026)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it24604 - Convention (Subpart B), Gross Ton
13648 - Convention (Subpart B), Net Ton
40652 - Dead Weight, Metric Ton
50245 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

18 June 2026 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8395972
2 October 2024 Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8009847
30 September 2024 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8011669
23 September 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8008052
21 March 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7410592
10 November 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6852144
10 August 2017 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6236728
8 August 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6226072
23 July 2016 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5950208
8 June 2016 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5900942
16 July 2015 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5181617

Deficiency record · 7

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 October 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks or flammable liquids. PSCO observed fuel oil leak on quick closing valve on emergency generator. 74 SOLAS (20) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2024
Resolution: PSCO verified Vessel replaced packing glands and gaskets on fuel oil leak on quick closing valve.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 October 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. PSCO observed excessive hydraulic oil leaking in steering gear room while conducting emergency steering test. 74 SOLAS (20) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2024
Resolution: PSCO verified Vessel re-tightened all upper bolts on rudder stock and secured bolts "wire ties".
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 October 2024 Resolved
Where a fixed gas fire extinguishing is used, openings which may admit air to, or allow gas to escape from, a protected space shall be capable of being closed from outside the protected space. PSCO observed multiple fire caps missing on cargo hold drain valves protected by CO2. 74 SOLAS (20) II-2/10.4.2
Action required: 15 - Rectify deficiencies by next port
Resolved 4 October 2024
Resolution: PSCO verified Vessel were able to find and replace all missing fire caps on all cargo hold drain locations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 November 2019 Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebouys self-igniting lights complying with the requirements of paragraph 2.1.2 of the code multiple lifebuoys lights did not ignite when tested. 74SOLAS (14)III/7.1.3 17C,10C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2019
Resolved 10 November 2019
Resolution: Replaced batteries on lifebuoys with self-igniting lights.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 10 November 2019 Resolved
International Shore Connections shall have 8 washers. the International Shore Connection was missing four washers in both locations. 74SOLAS(14)II-2/10.2.1.7.1 FSS 2.2.2 10C
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 November 2019
Resolved 10 November 2019
Resolution: Added washers to each location.
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 8 August 2017 Resolved
9900-Other (not clearly hazardous)-The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operate in the waters of the United States must employ one of the ballast water management methods listed in 33 CFR 151.2025. Vessel is outfitted with an approved alternate management system described in 33 CFR 151.2025(a)(3). 33 CFR 151 2025, 15c
Action required: 15 - Rectify deficiencies by next port
Resolved 10 August 2017
Resolution: Class Report Recieved
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 30 July 2016 Resolved
Fire-Fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSC Officer observed 09 CO2 system nozzle heads in the floor level of the engine room were painted over clogging the discharge port openings and restricting effectiveness and operational readiness of the fire suppression system. 74 SOLAS (14 CONS ED) II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2016
Resolution: Vessel removed all CO2 nozzle heads and cleaned remaining paint. PSC received the attending Classification Societies attestation that the nozzles were cleaned and free of any obstructions.