Records from 2005 to 2026. Most recent: inspection, 23 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 17
23 January 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8300534
15 December 2025
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8283349
4 November 2024
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8019673
1 October 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8012656
7 December 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7834703
9 June 2023
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700325
18 May 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7691660
9 December 2021
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7382856
10 February 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7138282
2 March 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6917780
26 November 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6863223
26 November 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6863239
14 January 2019
Examination of Repairs · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6609792
2 February 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6348306
4 December 2017
Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6356496
8 February 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6084529
22 January 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5801587
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 January 2026
Resolved
"On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level..." Vessel audible bilge alarm at operating station is inoperable, along with visual bilge alarm for parlor. Fix bilge alarms at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 9 February 2026
Resolution: Received videos of 04 audible/visual bilge alarms at bridge
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 January 2026
Resolved
"A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry: six hand red flare distress signals... and; six hand orange smoke distress signals..." Vessel's red flares are expired. Replace with the appropriate amount of flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2026
Resolved 19 February 2026
Resolution: Rcvd photo of unexpired flares onboard
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 January 2026
Resolved
"Except on a vessel limited to daytime operations, the compass must be illuminated." Vessel's compass is not illuminated. Provide illumination prior to operating at night.
Action required: 705 - Other - as specified
Resolved 9 February 2026
Resolution: Received video of magnetic compass illumination
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 November 2024
Resolved
46 CFR § 177.10-5 Fire protection: The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Marine inspectors found missing fireproof material in the forward engine room overhead. Submit repair plan for approval.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 November 2024
Resolution: Wtinessed new fire stop foam added to deck penetration
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024
Resolved
46 CFR § 183.350 Batteries - General: Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Marine inspectors found water in a battery casing on the starboard side of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 November 2024
Resolution: Battery box found free of water
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 November 2024
Resolved
Small unfired pressure vessels which do not fully comply with the requirements of this subchapter may be accepted by the Commandant for installation on vessels subject to inspection by the U. S. Coast Guard, provided:
1. The failure of such unfired pressure vessels will not endanger the safety of the vessel.
2. The internal volume does not exceed 5 cubic feet.
3. The construction complies with the requirements of a recognized code, or tests as prescribed by the Commandant are carried out to prove that the design and fabrication are suitable for the intended application.
4. Such unfired pressure vessels shall otherwise comply with the requirements for plan approval and marking as specified in this subchapter.
2 gal air compressor used for horn on board does not have the ASME stamp and must be replaced within 14 days.
46 CFR 54.01-5(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 8 November 2024
Resolution: UPV removed and replaced horn with electric horn
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 October 2024
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
This vessel's COI anniversary date is 09 JUN 2023. It lapsed is latest date to conduct a 1st annual inspection 09 SEP 2024. Schedule a COI renewal through [email withheld] to clear.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2024
Resolution: Issued COI
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 June 2023
Resolved
Each water light must be of an approved automatic electric type constructed in accordance with subpart 161.010 of this chapter. The light attached to the ring bouy on board was expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2023
Resolved 29 June 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2023
Resolved
The master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter... The vessel may not depart until it is in compliance with these requirements. Vessel was not found in compliance with conditions of their stability letter for deck cargo. Boom is stored too high off the weather deck.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2023
Resolved
All valves in the fuel lines shall be tested by operation locally and at remote operating positions. Fuel shutoff valves were found to be inoperable at the time of inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2023
Resolved
The power fire pump shall be self priming and of such size as to discharge an effective stream form a hose connected to the highest outlet. Fire pump did not build up enough discharge pressure to be considered an effective stream and be utilized for its intended purpose.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2023
Resolved
The means provided for pumping bilges shall be tested by operation. Vessel's bilge system was inoperable at the time of inspection and inspectors were unable to witness the proper operation of the bilge pump
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 June 2023
Resolution: Bilge pump restored to operational status
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2023
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. At the time of inspection, vessel's main steering ram was found actively leaking oil. Replace leaking steering ram.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2023
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Wire feed through aft engine room bulkhead on the starboard side require fire stop or a suitable alternative.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 June 2023
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Helm pump was found leaking hydraulic fluid at the time of inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2023
Resolved
Rails or equivalent protection shall be installed near the periphery of all-weather decks accessible to passengers and crews. Multiple stanchions were missing, and rails were not tightened.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 9 June 2023
Resolved
A hatch exposed to the weather must be watertight.
Hatch to fore peak was not watertight.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 June 2023
Resolved
A hatch exposed to the weather must be watertight. Replace deteriorated gasket on the hatch on top of the slop tank.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 May 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
Vessel missed its fourth annual inspection due 14Apr2023.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2023
Resolved 9 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 January 2019
Resolved
Examine all accessible parts of the exterior and interior hull to assess the condition of the hull structure. There is a hole through the hull, starboard side, engine room. 46 CFR 176.25-5(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2019
Resolution: Hull portion was cropped and renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 January 2019
Resolved
Liquid level indicating gages shall be of heat resistant materials and adequately protected from mechanical damage. The liquid level gages in the engine room were constructed of plastic and not protected from damage. 46 CFR 180.20-25(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 13 February 2019
Resolution: Plastic replaced with glass and protective rods.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 January 2019
Resolved
Each opening port light must be constructed so that it can be secured watertight. The port-side port light in the engine room has a crack running through it. 46 CFR 171.116(f)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 13 February 2019
Resolution: Cracked glass replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 January 2019
Resolved
A vessel of less than 20m must have a sound signal with a range of at least .5 nautical miles. The sound signal is not strong enough to be heard at .5 nautical miles. 33 CFR 83.33(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 13 February 2019
Resolution: Compressor for horn was repaired, fully functional.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2019
Resolved
Batteries shall be effectively screened to minimize the risk of accidental sparks through dropping of metallic items on the connections. The battery forward of the generator has no cover. 46 CFR 183.05-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 13 February 2019
Resolution: Battery cover provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2019
Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. Wires for the bilge pumps were spliced with electrical tape. 46 CFR 183.05-50(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 13 February 2019
Resolution: Splices enclosed in a junction box.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 January 2019
Resolved
An inspection of the bridge-to-bridge radio stations on board vessels subject to the Vessel Bridge-to-Bridge Radiotelephone Act must be conducted by an FCC-licensed technician. The Safety Radiotelephony certificate was expired. 47 CFR 80.59(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 13 February 2019
Resolution: Certificate renewed and valid.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 January 2019
Resolved
Life ring buoys must be approved in accordance with 160.050. Both life ring buoys on the vessel had grab lines that were weathered to the point of breaking and fraying. 46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2019
Resolved 13 February 2019
Resolution: Grab lines replaced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 January 2019
Resolved
The fuel shutoff valve at the tank shall be operable from outside the compartment. The fuel shutoff reach rod was disconnected from the fuel line valve. 46 CFR 182.20-40(b)(3)
Action required: 10 - Deficiency Rectified
Resolved 14 January 2019
Resolution: Reach rod reconnected in the presence of the MI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 January 2019
Resolved
A vessel must carry adequate and up-to-date charts. The charts had not been updated with notices to mariners. 46 CFR 184.420(a)(1)
Action required: 10 - Deficiency Rectified
Resolved 14 January 2019
Resolution: Charts updated in the presence of the MI.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 February 2018
Resolved
Provide ground detection.
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 2 April 2018
Resolution: Extended from 2/16 to 2/28 to facilitate order/shipping/installation time. Extended again to 3/16. Still awaiting parts. Cleared deficiency, vessel added ground fault detection system & special note will be added to vessel details.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 February 2017
Resolved
There are several broken stanchions onboard, these need to be replaced to provide more stable railing. The cables used as courses on the deck rails are not properly spaced, re-run the cables to provide the required 12" spacing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: MI's attended to vessel to review replaced stanchions.