HAFNIA AQUAMARINE is a 2015 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in March 2026, along with 4 deficiencies — 1 with no resolution recorded — and 4 operational controls.
Records from 2016 to 2026. Most recent: inspection, 4 March 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it23676 - Convention (Subpart B), Gross Ton 10252 - Convention (Subpart B), Net Ton 38506 - Dead Weight, Metric Ton 47506 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 4 March 2026No resolution recorded
Automatic shutdown of cargo pumps shall be provided to operate on predetermined limits of low pressure in the inert gas main being reached. PSCO observed cargo pumps remained on after the low pressure alarm sounded. After ship's crew conducted visual inspection and cleaning of electrical leads within the cargo pump operating panel, subsequent shutdowns were satisfactorily observed.
74 SOLAS (20) II-2/4.5.5.1.1
FSS Code 2.2.4.5.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 August 2023Resolved
EACH EMERGENCY GFENERATING SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH STARTING DEVICES APPROVED BY ADMINISTRATION WITH A STORED ENERGY CAPABILITY OF AT LEAST 3 CONSEQUETIVE STARTS. A SECONDARY SOURCE OF ENERGY SHALL BE PROVIDED FOR AN ADDITIONAL 3 STARTS. DURING TEST OF EMERGENCY GENERATOR, PSCO'S OBSERVED MALFUNCTION OF STARTER WHICH RESULTED IN AN ELECTRICAL FIRE, RENDERING AUTOMATIC START FUNCTION INOPERABLE. 74 SOLAS (20) CH II-1/44.2
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2023
Resolved 25 August 2023
Resolution: Cleared deficiency after satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 March 2019Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSC Officer observed approximately 1-1/2" hole at the aft drain line connection to the fixed deck foam main supply line. Vessel is restricted from conducting cargo operations until repairs are made to the satisfaction of Class Society and attending U.S. Coast Guard Inspector. 74 SOLAS (14) CH.II-2/Reg.14.1.1. Action 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2019
Resolved 22 March 2019
Resolution: Class surveyor attended vessel and confirmed that a temp repair using a clamp was installed on the fixed deck foam main supply line drain hole. Operational test was conducted using two main fire pumps and two foam monitors with no leakage found.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 March 2019Resolved
Sufficient foam concentrate shall be supplied to ensure that at least 30 min of foam generation when using the highest of the solution rates stipulated. PSC Officer observed approximately 1-1/2" hole at the aft drain line connection to the fixed deck foam main supply line. 74 SOLAS (14) Ch. VII/10.1, IBC Code 11.3.6. Action 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2019
Resolved 22 March 2019
Resolution: Class surveyor attended vessel and confirmed that a temp repair using a clamp was installed on the fixed deck foam main supply line drain hole. Operational test was conducted using two main fire pumps and two foam monitors with no leakage found.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.