← All vessels
CLARABELLE
Freight Ship · Bulk Carrier class · Built 2010s · USCG Northeast District (CGD-NE) · Other hulls named CLARABELLE
CLARABELLE is a 2014 freight ship. The Coast Guard has recorded 13 inspections since 2015, most recently in March 2026, along with 7 deficiencies and 1 operational control.
Records from 2015 to 2026. Most recent: inspection, 15 March 2026.
- Built
- 2014
- Last inspected
- 15 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9695004 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CQ2425
1350890
Flag
PORTUGAL
—
Maury page id
psix-1350890
Inspections, by type
…with no type recorded1
Years with a record
9 calendar years (2015–2026)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it23247 - Convention (Subpart B), Gross Ton
12461 - Convention (Subpart B), Net Ton
46124 - Displacement, Metric Ton
37430 - Dead Weight, Metric Ton
12461 - Convention (Subpart B), Net Ton
46124 - Displacement, Metric Ton
37430 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
15 March 2026
COE-Administrative
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8326305
4 November 2025
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8260395
16 April 2024
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7895937
20 February 2024
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7871212
28 March 2023
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7658445
22 February 2023
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7637878
13 July 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7254643
7 June 2021
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7213042
3 August 2018
COE-Dockside · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6495270
22 December 2017
Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6327087
18 December 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6326057
22 September 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6001275
4 August 2015
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5196117
Deficiency record · 7
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 22 February 2023
Resolved
EACH CONTAINER SHALL BE CLEARLY MARKED WITH DATE OF PACKAGING AND DATE OF EXPIRY. PSCO OBSERVED THAT NONE OF THE CONTAINERS OF WATER WERE MARKED WITH MANUFACTURER DATE OR EXPIRY DATE.
74 SOLAS (20) III/13.4
LSA 4.1.5.1.19
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 22 February 2023
Resolved
ALL ACCESS OPENINGS IN BULKHEADS AT ENDS OF ENCLOSED SUPERSTRUCTURES SHALL BE FITTED WITH DOORS OF STEEL AND FITTED SO THAT THE WHOLE STRUCTURE IS OF EQUIVALENT STRENGTH TO THE UNPIERCED BULKHEAD AND WEATHERTIGHT WHEN CLOSED. PSCE OBSERVD SUNLIGHT COMING THROUGH THE EXTERNAL DOOR LEADING TO PROVISIONS STORE WHEN LATCHED.
ICLL 66 1/12
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 22 February 2023
Resolved
...THE ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUVE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD.PSCE OBSERVED WATER LEAKING FROM A PIPE FITTING DURING THE RECIRCULATION TEST OF THE OWS.
74 SOLAS (20) II-2/4.2.2.6.1
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 22 February 2023
Resolved
SURFACES WITH TEMPERATURES ABOVE 220 C WHICH MAY BE IMPINGED AS A RESULT OF A FUEL SYSTEM FAILURE SHALL BE PROPERLY INSTALLED. PSCE OBSERVED DETERIORATING LAGGING ON ONE OF THE PIPES IN THE PURIFIER ROOM.
74 SOLAS (20) II-2/4.2.2.6.1
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 June 2021
Resolved
Fixed fire detection and fire alarm systems shall be periodically tested by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range of desity or particle size, or other phenomena associated with incipient fires to which the fire detector is designed to respond. The equipment required by the manufacturer's instructions to test flame detectors is not onboard.
- 74SOLAS(20)II-2/7.3.2 (16ac)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 August 2018
Resolved
99101-Other (safety in general) PSCO observed previously submitted NBIC reports failed to indicate onboard treatment conducted. PSCO verified treatment was conducted via onboard BWMS history log. However vessel Ballast Water Record Book does not clearly indicate onboard treatment due to record keeping format. RO to provide clarification as to process for recording onboard treatment (eg. code 3.1 and 3.2) PSCO provided education to captain on NBIC report format. 33 CFR 151.2060. 16a
Lifesaving › Lifeboat › Propulsion Starting System
Issued 22 December 2017
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving applainces shall be in working order and ready for immediate use. Upon boarding the vessel, the Captain informed the PSCO that the stern-launch lifeboat battery was not holding a charge and would not start the engine. PSCO confirmed lifeboat would not start. This discrepancy was discovered two days ago enroute to Boston. A purchase order was placed, and a new battery will be received 22Dec17 (today) to replace the bad battery. Ship's company and class were notified.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.