Records from 2016 to 2026. Most recent: inspection, 4 January 2026.
Inspection history · 16
4 January 2026
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8287362
30 July 2024
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7965702
27 July 2023
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7742571
2 August 2022
PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7517911
4 June 2021
PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7213281
8 August 2020
COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7021639
23 May 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6971787
26 June 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6726369
12 May 2019
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6678715
26 September 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6549465
23 October 2017
COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6289464
16 August 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6242961
10 August 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6236510
18 July 2017
Administrative Inspection · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6212953
10 May 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6141986
5 December 2016
Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6049393
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 22 July 2017
Resolved
Vessel conducted untreated empty refill exchange after compliance date listed in 33CFR151.2035(b). Vessel must conduct a treated ballast exchange outside of 12nm utilizing their AMS prior to discharging ballast in US waters.
The Vessel's installed AMS has been inoperable since 27MAR17
Cite: 33CFR151.2025(a)(3) Action Taken: 40c.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 July 2017
Resolved 10 August 2017
Resolution: Received class report attesting to the fact that BWTS has been repaired and is fully operational at this time.
Operations/Management › Ballast Water Managment › Training
Issued 22 July 2017
Resolved
Vessel's ballast water management plan does not include all of the necessary provisions listed in 33 CFR 151 Subpart D. Vessel's ballast water management plan must include provisions listed in 33 CFR 151.2050(g).
Cite: 33 CFR 1512050 (g) Action taken: 40c
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 July 2017
Resolved 16 August 2017
Resolution: Received revised USA specific appendix to BWM plan that is vessel-specific and addresses the current U.S. regulatory requirements. Revised appendix uploaded to 'Documents' tab for reference.