← All vessels
GLOVIS SOLOMON
GLOVIS SOLOMON is a freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in July 2024, along with 2 deficiencies and 1 operational control.
Records from 2016 to 2024. Most recent: inspection, 26 July 2024.
- Built
- Not recorded
- Last inspected
- 26 July 2024
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9445409
D7GS
1352635
Flag
SOUTH KOREA
Maury page id
psix-1352635
Inspections, by type
…with no type recorded2
Years with a record
4 calendar years (2016–2024)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it72946 - Convention (Subpart B), Gross Ton
26985 - Dead Weight, Ton
26202 - Convention (Subpart B), Net Ton
26985 - Dead Weight, Ton
26202 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 8
26 July 2024
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7966796
7 January 2023
PSC B · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7618000
24 September 2018
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6547776
6 September 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6524699
9 September 2016
ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5989573
3 September 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5991934
3 September 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6014721
1 September 2016
COE-Administrative
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6001989
Deficiency record · 2
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 6 September 2018
Resolved
The decks shall be constructed of steel or other equivalent material. Several sections of the house decking were found to be warped. The condition of the deck cannot be verified due to a laminated surface. No documentation could be provided attesting to the condition of the steel or concrete prior to the insulation installation. 2014 SOLAS CH II-2 REG 11
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 6 September 2018
Resolved
Every ship shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the administration. The rudder angle transmitter was found with a missing cotter pin and nut. 2004 SOLAS CH II-1 Reg 29.1 and 29.2.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.