Records from 2004 to 2026. Most recent: inspection, 25 March 2026.
Documentation record
Registered dimensions (L × B × D)52.2 ft × 22.2 ft × 8.2 ft
Registered tonnagegross 76 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMASTER MARINE, INC. · BAYOU LA BATRE AL, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 5 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
25 March 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8331870
27 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8145232
20 August 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8099177
25 May 2023
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7696125
12 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7686880
9 December 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7606851
16 November 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7352098
8 May 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6950374
6 March 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6921853
21 February 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6913258
19 October 2019
Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6841559
26 February 2018
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6403357
1 October 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6284927
13 January 2015
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5057278
23 February 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4538856
18 January 2012
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4227981
6 December 2011
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4207480
7 September 2011
MTSA/ISPS Verification · Industry Initiated Exam · Administration
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4139245
24 January 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3932163
16 December 2009
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3660477
15 December 2009
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3660524
26 October 2006
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2808821
11 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2004933
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 May 2023
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202.
Complete COI inspection prior to conducting towing operations.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 June 2023
Resolution: COI inspection complete. Vessel is certificated under subchapter M.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 16 November 2021
Resolved
Towing vessels must be equipped with a Fathometer except when operating on Western Rivers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2021
Resolved 29 November 2021
Resolution: Depth sounding device installed. OPTEST SAT.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 February 2020
Resolved
All bilges and void spaces are kept free from
accumulation of combustible and flammable materials and
liquids insofar as practicable. Identified excessive amounts of oil throughout the engine room bilge, up to 12 inches of almost straight oil with minimal to no water, adjacent to the fuel trap in the centerline of the bilge, with oil also beneath the generators and main engines, posing an imminent hazard to the crew & environment, a serious substandard condition not being pro-actively managed. Remove all oil and clean the bilge in engine room, before vessel movement. 46CFR142.220(a)
Action required: 30 - Ship detained
Resolved 6 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 February 2020
Resolved
All fire detection systems must be serviced every 12 months. The fire detection panel upon arrival was missing both emergency power batteries which renders the panel useless if main power is lost, and in addition, no records of annual servicing could be found since the system was installed by a P.E. in 2012. Furthermore, crew had no means to test the fire detection system, obtain the proper method per the fire detection manufacturer manual. A proper servicing company needs to service the system, before vessel movement. 46CFR142.240(a)
Action required: 30 - Ship detained
Resolved 6 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 February 2020
Resolved
A B–II portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by Tables 142.230(d)(1) and 142.230(d)(2) of § 142.230. This B-II extinguisher was missing from its required location, place a B-II there as soon as possible. 46CFR142.225(d)
Action required: 30 - Ship detained
Resolved 6 March 2020
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 February 2020
Resolved
Each towing vessel must be fitted with a general alarm that is capable of notifying persons in any accommodation, work space, and the engine room. Vessel only had audio alarm in the galley, not audible in the engine room when machinery is running or the main deck, presenting a danger to the crew safety if an emergency arises. 46CFR143.235
Action required: 30 - Ship detained
Resolved 6 March 2020
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 21 February 2020
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. The only emergency lighting on the vessel was a dim/useless light near the fuel trap facing the bilge and the galley, and no sufficient lighting to help the crew escape from the bottom to the top of the engine room, nor lighting in the overnight bunk spaces for crew. Install at these areas and test under emergency power, prior to operating the vessel under its own power. 46 CFR 143.410
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 February 2020
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that
alerts individuals in those spaces. No smoke detectors installed in the crew bunk space near the wheelhouse creating a danger to crew safety if fire/smoke arises. 46 CFR 142.330(b)
Action required: 30 - Ship detained
Resolved 6 March 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 February 2020
Resolved
The master must ensure that all hatches, doors, and
other openings designed to be watertight or weathertight
function properly. Both the port and starboard shaft packings were leaking water at a steady rate, approximately a cup of water every 15 seconds, while the engines and shafts were stationary not under power, creating excessive water into the bilge. Tighten the shaft packing properly as designed. 46 CFR 140.610(b)
Action required: 30 - Ship detained
Resolved 6 March 2020
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 21 February 2020
Resolved
The safety of the towing vessel is the responsibility of the master and includes: Compliance with the applicable provisions of this subchapter and supervision of all persons onboard in carrying out their assigned duties. Licensed operators and crew not aware that the deficiencies 1-7 and 9 of this form were unsafe and did not take proactive management/action to correct them. 46CFR140.210(a)
Action required: 30 - Ship detained
Resolved 6 March 2020
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 February 2020
Resolved
The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. Witnessed two fuel tanks with valves aft of the tank, but the remote fuel shut off valve was several feet downstream, aft of piping diversions and other valves. Add remote shut off devices to the existing valves at the tank. 46CFR143.260(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2020