Records from 2017 to 2026. Most recent: inspection, 25 February 2026.
Documentation record
Registered dimensions (L × B × D)36.1 ft × 12.0 ft × 2.5 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROOKIE BOATS OF MS LLC · BAY ST LOUIS, MS, UNITED STATES · built 2015
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Net Ton
9 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
25 February 2026
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8308204
13 February 2025
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8077559
26 February 2024
Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7861957
9 February 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7634441
14 March 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7392815
2 March 2021
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7148945
23 March 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6919799
26 March 2019
COI Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6649028
7 February 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6081745
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 February 2025
Resolved
A vessel not required to have a power driven fire pump must have at least 3 2.5 gallon buckets with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. MI found a fire bucket without proper stenciling.
46 CFR 181.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 17 February 2025
Resolution: Fire Bucket labeled properly
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. MI found life jacket storage compartments without proper markings.
46 CFR 185.604(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 17 February 2025
Resolution: Storage labeled properly
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 February 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of heavy weather, or man overboard conditions. MI found emergency instructions not posted. (along with COI and stability letter).
46 CFR 185.510(a)
46 CFR 176.302
46 CFR 176.306
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 17 February 2025
Resolution: Documents posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 February 2025
Resolved
A vessel of not more than 65 feet in length carrying not more than 12 passengers, with independent gasoline fuel tanks built in accordance with ABYC H-24, will be considered as meeting the requirements of this section. MI found fuel hose from tank to filter not ABYC approved. Vessel was previously approved by local OCMI for the above installation.
46 CFR 182.440(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 17 February 2025
Resolution: Fuel lines changed out.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 February 2025
Resolved
Each portable fire extinguisher on a vessel must be an approved type. MI found F/E brackets not of approved type for the F/E.
46 CFR 181.500(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 21 February 2025
Resolution: Sent photos of all new F/E brackets installed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 March 2022
Resolved
The Certificate of Inspection and Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request.
Vessel had expired COI and COD posted and in
weathertight container. Current COI, COD and Stability
letter must be kept on board at all times.
46 CFR 176.302; 46 CFR 176.306
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 15 March 2022
Resolution: Vessel provided satisfactory pictures that the deficiency has been rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 March 2022
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel's Water light did not have correct battery installed. Waterlight must use manufacture's approved battery.
46 CFR 180.70(d)(1)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 15 March 2022