SILVER QUEEN VI is a 1975 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 1985, most recently in June 2005, along with 11 deficiencies.

Records from 1985 to 2005. Most recent: inspection, 29 June 2005.

Built
1975
Last inspected
29 June 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

135490
Flag
UNITED STATES
—
Maury page id
psix-135490

Inspections, by type

…with no type recorded2
Years with a record 20 calendar years (1985–2005)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Net Ton
7 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

29 June 2005 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2407890
28 January 2003 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1738900
24 August 2002 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1665733
5 September 2001 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1379561
26 October 2000 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1361777
23 August 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1365339
15 December 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1445409
6 November 1997 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 784996
20 December 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1357821
3 January 1996 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080326
21 December 1995 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1182579
5 September 1995 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181505
27 April 1995 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1176836
2 May 1994 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1171041
4 May 1993 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 826533
13 May 1992 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 962426
9 May 1991 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1211048
18 December 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 904386
7 November 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 925495
9 May 1990 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 916343
23 May 1989 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1340550
10 May 1988 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1349511
2 June 1987 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1335183
14 May 1986 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1294150
7 May 1986 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 984655
1 November 1985 Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 993077
15 May 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 979973

Deficiency record · 11

Engineering › Bilge Water Management System
Issued 28 January 2003 Resolved
By Feb 3, 2003, install visible and audible bilge alarm at helm.
Due 3 February 2003
Resolved 5 February 2003
Engineering › Bilge Water Management System
Issued 28 January 2003 Resolved
By Feb 3, 2003,install visible indicator that shows when auto bilge pump is on at helm.
Due 3 February 2003
Resolved 5 February 2003
Documentation
Issued 15 December 1998 Resolved
PROVIDE OCMI WITH A CORRECTED COPY OF THE DOCUMENTION.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Electrical
Issued 3 January 1996 Resolved
REPLACE WIRE NUTS IN ELECTRICAL SYSTEM WITH APPROVED INSULATED CRIMP CONNECTIONS OR IN A JUNCTION BOX.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Electrical
Issued 3 January 1996 Resolved
REPLACE ALL 12 VOLT WIRING FROM SOURCE TO STEP LIGHTS, NAVIGATION LIGHT ANDHORN.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Engineering
Issued 7 November 1990 Resolved
RENEW BOTH PROPULSION SHAFT CUTLASS BEARINGS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Engineering
Issued 7 November 1990 Resolved
RENEW BOTH PROPULSION MOTOR FOUNDATIONS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Engineering
Issued 7 November 1990 Resolved
REPACK BOTH PROPULSION SHAFT STERN TUBE BUSHINGS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Construction/Loadline
Issued 7 November 1990 Resolved
RENEW THE PORT OUTBOARD BULKHEAD IN THE AFT BILGE PUMP AREA.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Engineering
Issued 7 November 1990 Resolved
REMOUNT BOTH PROPULSION ELECTRICAL CONTROLS IN BILGE AREA.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Construction/Loadline
Issued 7 November 1990 Resolved
RENEW THE WOOD BULKHEAD AFT OF THE PORT PROPULSION MOTOR.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.