Records from 1985 to 2005. Most recent: inspection, 29 June 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
29 June 2005
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2407890
28 January 2003
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1738900
24 August 2002
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1665733
5 September 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1379561
26 October 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1361777
23 August 1999
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1365339
15 December 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1445409
6 November 1997
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 784996
20 December 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1357821
3 January 1996
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080326
21 December 1995
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1182579
5 September 1995
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181505
27 April 1995
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1176836
2 May 1994
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1171041
4 May 1993
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 826533
13 May 1992
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 962426
9 May 1991
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1211048
18 December 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 904386
7 November 1990
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 925495
9 May 1990
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 916343
23 May 1989
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1340550
10 May 1988
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1349511
2 June 1987
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1335183
14 May 1986
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1294150
7 May 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 984655
1 November 1985
Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 993077
15 May 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 979973
Engineering › Bilge Water Management System
Issued 28 January 2003
Resolved
By Feb 3, 2003, install visible and audible bilge alarm at helm.
Due 3 February 2003
Resolved 5 February 2003
Engineering › Bilge Water Management System
Issued 28 January 2003
Resolved
By Feb 3, 2003,install visible indicator that shows when auto bilge pump is on at helm.
Due 3 February 2003
Resolved 5 February 2003
Documentation
Issued 15 December 1998
Resolved
PROVIDE OCMI WITH A CORRECTED COPY OF THE DOCUMENTION.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Electrical
Issued 3 January 1996
Resolved
REPLACE WIRE NUTS IN ELECTRICAL SYSTEM WITH APPROVED INSULATED CRIMP CONNECTIONS OR IN A JUNCTION BOX.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Electrical
Issued 3 January 1996
Resolved
REPLACE ALL 12 VOLT WIRING FROM SOURCE TO STEP LIGHTS, NAVIGATION LIGHT ANDHORN.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Engineering
Issued 7 November 1990
Resolved
RENEW BOTH PROPULSION SHAFT CUTLASS BEARINGS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Engineering
Issued 7 November 1990
Resolved
RENEW BOTH PROPULSION MOTOR FOUNDATIONS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Engineering
Issued 7 November 1990
Resolved
REPACK BOTH PROPULSION SHAFT STERN TUBE BUSHINGS.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Construction/Loadline
Issued 7 November 1990
Resolved
RENEW THE PORT OUTBOARD BULKHEAD IN THE AFT BILGE PUMP AREA.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Engineering
Issued 7 November 1990
Resolved
REMOUNT BOTH PROPULSION ELECTRICAL CONTROLS IN BILGE AREA.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990
Construction/Loadline
Issued 7 November 1990
Resolved
RENEW THE WOOD BULKHEAD AFT OF THE PORT PROPULSION MOTOR.
Condition: Unknown
Due 7 November 1990
Resolved 7 November 1990