MAURY USCG vessel records Sign in
← All vessels

Q5000

Q5000 is a 2015 mobile offshore drilling unit. The Coast Guard has recorded 38 inspections since 2015, most recently in September 2025, along with 11 deficiencies and 2 operational controls.

Records from 2015 to 2025. Most recent: inspection, 3 September 2025.

Built
2015
Last inspected
3 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8772104 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1355033
Flag
BAHAMAS, THE
—
Maury page id
psix-1355033

Inspections, by type

…with no type recorded8
Years with a record 11 calendar years (2015–2025)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it25197 - Convention (Subpart B), Gross Ton
25197 - Simplified, Gross Ton
7559 - Convention (Subpart B), Net Ton
7559 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

3 September 2025 COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8226371
25 April 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8120054
17 October 2024 ISPS Exam · COC-MODU Renew
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8021119
4 September 2024 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8020994
7 September 2023 COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7789291
13 November 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7595429
20 September 2022 Deficiency Check · COC-MODU Annual
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7564155
28 September 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7332123
27 September 2021 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7324795
13 September 2021 ISPS Exam · COC-MODU Renew · Ballast Water Examination
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7311608
9 April 2021 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7195422
29 March 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7165122
29 March 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7167053
8 February 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7137694
2 September 2020 Ballast Water Examination · ISPS Exam · COC-MODU Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7055804
27 December 2019 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6878833
24 December 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6878630
1 October 2019 COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6827694
17 August 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6825473
22 April 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6683946
27 January 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6633322
19 December 2018 COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6599633
19 October 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6565953
1 October 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6552446
8 September 2017 COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6262563
9 July 2017 In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6203011
18 June 2017 In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6179117
29 May 2017 In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6159364
24 January 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6076064
23 August 2016 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5981808
4 August 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5968706
16 April 2016 In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5855431
23 February 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5820293
23 February 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5826896
15 October 2015 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5745310
15 October 2015 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5753796
17 September 2015 Ballast Water Examination · COC-MODU Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5724982
25 August 2015 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5774869

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 September 2022 Resolved
Each unit should carry at least one rescue boat complying with the requirements of the LSA Code, and be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the organization. 09 MODU Code 10.8 LSA Code 1.2.2.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 21 September 2022
Resolution: Photos were provided showing the installation of new retro-reflective material.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 March 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel ran aground departing port of Pascagoula, [name withheld] surveyor shall attend to ensure vessel is fit to proceed to sea without danger to the ship or persons on board.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 March 2021
Resolved 10 April 2021
Resolution: Received Survey Report from ABS attesting that the vessel is fit to proceed to sea. Thruster number 7 was removed due to damage from grounding and sealed with a bottom cover assembly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 September 2020 Resolved
The smoke detector located in the laundry room did not function as designed when tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2020
Resolved 3 September 2020
Resolution: Smoke detector unit in the laundry room was replaced and tested by ships crew, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 September 2020 Resolved
The OEM maintenance requirements for the releasing gear is not being followed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: Lifesaving maintenance checklist was updated to reflect the OEM inspection requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 October 2019 Resolved
OEM requires lifeboat hooks to be operate monthly. Lifeboats are currently being launched quarterly. Reconcile with OEM and Administration. 09 MODU Code 10.18.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 22 October 2019
Resolution: OEM provided letter stating quarterly maintenance will suffice in lieu of monthly operation of the hooks as required in the manual. See documents.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 March 2016 Resolved
Rotating machinery will be equipped with guard for the protection of crew. Thruster shafts are unguarded and needs to be guarded prior to next Coast Guard annual COC exam.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 April 2016
Resolved 10 March 2016
Resolution: Guards were added to all thruster to the satisfaction of the attending ABS surveyor.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 3 March 2016 Resolved
Fire boundaries must be maintained. Multiple marine cable transits throughout the vessel are still disassemblied and need to be reassembled and place back in service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2016
Resolved 10 March 2016
Resolution: All MCT's that were called out as a class outstanding have been repaired to the satisfaction of the attending ABS surveyor.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 March 2016 Resolved
Scullery fire door does not close with the installed self-closure device.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2016
Resolved 10 March 2016
Resolution: Scullery door has been adjusted to the satisfation of the attending ABS surveyor
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 March 2016 Resolved
Emergency lighting required in machinery spaces, noted sevearl emergency lights that were extinguished throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 April 2016
Resolved 10 March 2016
Resolution: Burnt out bulbs were replaced and placed back in service to the satisfaction of the attending ABS surveyor.
Communications › Alarms/Indicators › Fire Alarm
Issued 17 September 2015 Resolved
A FIXED AUTOMATIC H2S GAS DETECTION AND ALARM SYSTEM BE PROVIDED TO SATISFACTION OF ADMIN ARRANGED AS TO MONITOR CONTINUOUSLY THE DRILLING, MUD PROCESSING AND WELLFLUID TEST AREAS OF THE UNIT AND CAPABLE OF GIVING AUDIBLE/VISUAL ALARM AT MAIN CONTROL POINTS. FOUND ALL GAS DETECTORS COVERED UP AND NOT FUNCTIONING. 09 MODU CODE 9.12 (66 B,C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 15 October 2015
Resolution: All Gas detection has been calibrated and tested.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 September 2015 Resolved
FIRE INTEGRITY OF BULKHEADS/DECKS IN THIS SECTIONAND IN SECTION 9.3 THE MINIMUM FIRE INTEGRITY OF BULKHEADS/DECKS SHOULD BE AS PRESCRIBED IN TABLE 9-1 AND 9-2. NUMEROUS MARINE CABLE PENETRATIONS THRU A-60 BULKHEADS MISING BLOCKS. 09 MODU CODE (66 B,C)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 15 October 2015
Resolution: All MCT have been installed as per manufacturer's instructions.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.