← All vessels
MISS HADLEY
MISS HADLEY is a 2015 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2017, most recently in October 2025, along with 49 deficiencies and 1 operational control.
Records from 2017 to 2025. Most recent: inspection, 24 October 2025.
- Built
- 2015
- Last inspected
- 24 October 2025
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 49 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1265061
1355305
Flag
UNITED STATES
Maury page id
psix-1355305
Inspections, by type
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 3.8 ft
Registered tonnagegross 13 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT PONTOONS INC · TAVARES, FL, UNITED STATES · built 2015
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTri Hull
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 3 October 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
13 - Displacement, Gross Ton
13 - Simplified, Net Ton
13 - Dead Weight, Net Ton
13 - Displacement, Gross Ton
13 - Simplified, Net Ton
13 - Dead Weight, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 18
24 October 2025
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8254631
29 April 2025
Administrative Inspection · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8123474
4 April 2025
Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8105092
7 January 2025
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8059673
17 January 2024
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7850521
28 March 2023
In-Service Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7658690
6 March 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7646012
17 February 2022
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7397901
8 February 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7392719
21 October 2021
Examination of Repairs · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7337222
27 October 2020
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7070221
17 January 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6891616
6 September 2019
Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6805327
28 January 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606579
22 June 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6452621
29 January 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6345167
19 September 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6266395
10 January 2017
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6068822
Deficiency record · 49
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2025
Resolved
Suitable life jackets must be provided for all persons onboard. 20 adult life jackets were taken out of commission. Limited to 82 persons total.
46 CFR 180.71(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2025
Resolved
Suitable life jackets must be provided for all children onboard. Two child life jackets were taken out of commission. Limited to 9 children.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2025
Resolved
Fuel tank fills must be bonded to protect against static charge. Fuel tank fills were not bonded to fuel tank.
46 CFR 182.445(g)
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 October 2025
Resolved
The owner or manger operator must provide servicing reports. Fire servicing records for fire extinguishers were not provided.
46 CFR 176.810
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 24 October 2025
Resolved
Each vessel must be marked as required. Vessel did not have a load mark.
46 CFR 185.602(c)(2)
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 April 2025
Resolved
Each vessel must comply with the Type II subdivision and damage stability requirements...(2) Carries more than 49 passengers.
Due to compromised pontoon chambers in P1-P3, P9-10, and S1-S2, vessel is limited to 49 passengers until repairs are witnessed by the attending MI.
46 CFR 179.212(a)2
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 4 April 2025
Resolved
Electrical equipment on a vessel must be installed to... protect the vessel from electrical hazards. Inverter is wired into a recepticle using extension cord style pigtail. remove inverter.
46 CFR 183.200
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2025
Resolved
A vessel must carry an approval series 160.041 first aid kit. Vessel missing required contents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2025
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Improper mounting of portable fire extinguisher. Provide approved fire extinguisher mounting bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 January 2025
Resolved
A vessel on a rivers routes must carry three hand red flares. Vessel did not have 3 red flares. Provide 3 red flares. Vessel limited to daylight operations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 January 2025
Resolved
A vessel must have one or more ring life buoys as follows. Lanyard attaching waterlight to life buoy needs to be of the same material as life buoy lifeline.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of...navigation rules.
All-around light aft portion is extinguished.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of...navigation rules.
Stern light is not of an approved type.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 January 2024
Resolved
A vessel must have...at least three 9.5 liter (2 1/2) gallon buckets with an attached lanyard. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket.
One bucket was broken and the other two buckets were not labeled. Replace broken bucket, label all, and put lanyards on them.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 January 2024
Resolved
A vessel on a rivers route must carry: 3 red hand flare distress signals and 3 hand orange smoke disress signals.
1 flare and 1 orange smoke were expired. Replace with valid distress signals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2024
Resolved
Electrical equipment exposed to the weather must be watertight.
Exposed wires on overhead light near operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2024
Resolved
Each battery must be...secured against shifting with the roll and pitch of the vessel.
Two batteries wre not secured in boxes.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2024
Resolved
A vessel must varry a first aid kit approved under approval series 160.041 or a kit with equiavlent contents and instructions.
First aid kit had expired components.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 March 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. The insets observed on the STBD pontoon present an unnecessary risk to the safe operation of the vessel. Conduct pressure test of all damaged chambers to the satisfaction of the attending marine inspector and draft a repair proposal for the damaged sections.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 28 March 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Correct the following items prior to the carriage of passengers:
a) Pinhole leak on top of starboard chamber 8.
b) Compromised baffle between port chambers 1 & 2.
c) Leaks throughout temporary repair in port chamber 3.
d) Leak on outboard and inboard welds along the aft edge of port chamber 10.
Vessel representative must submit repair proposals for items listed prior to any work being completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2023
Resolved
An adult life jacket must be provided for each person
carried on board a vessel. In addition, a number of
child size life jackets equal to at least 10% of the
number of persons permitted on board must be provided.
Inspectors found 66 adult and 6 child lifejackets that
were serviceable. Passengers are limited to 64 adults
and 6 children until adequate lifejackets are provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2023
Resolved
Each ring life buoy must be marked with Type II
retroreflective material approved in accordance with 46
CFR 164.018. Each ring life buoy must be marked in
clearly legible block capital letters with the vessel's
name. Ring life bouy is missing retroreflective material
and vessel name.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 March 2023
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect passengers, crew, other persons,
and the vessel from electrical hazards, including fire,
caused by or originating in electrical equipment, and
electrical shock. Terminal connections near battery
switch found exposed. Install adequate protection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2023
Resolved
A vessel must carry one floating waterlight approved in
accordance with § 161.010 in subchapter Q of this
chapter. Battery in waterlight does not conform to
manufacturer specifications. Install approved battery.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2023
Resolved
Deck rails must be designed and constructed to withstand
a point load of 91 kilograms (200 pounds) applied at any
point in any direction, and a uniform load of 74
kilograms per meter (50 pounds per foot) applied to the
top rail in any direction. Permanently repair crack in
railing on port fwd corner of vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 February 2022
Resolved
To maintain a valid Certificate of Inspection (COI) you must complete your annual inspection within the periods specified in 46 CFR 176.500(b)(1) and your certificate must be endorsed.
The vessel did not conduct an annual inspection within the approved three month period and the current COI has not been endorsed.
Vessel is not authorized to carry passengers until a COI inspection has been completed.
46 CFR 176.502
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 October 2021
Resolved
Multiple cracks found on both engine transoms. Repair welds.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 January 2020
Resolved
Each life jacket must be marked with type I retroreflective material. Identified 03 life jackets with worn retroreflective tape. Replace retroreflective tape. Passenger count is reduced by 03.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2019
Resolved
An adult lifejacket must be provided for each person carried on board. 46 lifejackets were unserviceable, 08 lifejackets need new retroreflective tape. Replace/repair lifejackets. Passenger count reduced to 46.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 January 2019
Resolved
Ring life buoys must be fitted with retroreflective tape. Tape was missing. Install retroreflective tape.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 January 2019
Resolved
Nonmetallic hose must comply with SAE J-1475. Starboard fuel tank had one clamp that was corroded and loose. Provide functional double hose clamps.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 January 2019
Resolved
Three 2.5-gallon fire buckets are required. Vessel has three 2-gallon buckets. Replace with 2.5-gallon buckets.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 January 2018
Resolved
07 adult lifejackets missing vessel name.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 January 2018
Resolved
4 adult lifejackets and 4 child lifejackets missing retro. 4 child lifejackets were in excess of minimum required (11). Passenger count reduced from 100 to 96 until adult lifejacket def is resolved.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 January 2018
Resolved
Water light found not to be operational. Vessel restricted to daytime ops until proper operation is demonstrated.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 29 January 2018
Resolved
Fire extinguisher at bow missing tamper seal. Service extinguisher as required.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 January 2018
Resolved
All three fire extinguishers improperly secured to mounting brackets.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 January 2018
Resolved
Two portable battery flashlights are required. Only one onboard, which was not functional. Provide two functioning lights.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 January 2018
Resolved
Permanently affix overhead light at fwd end of accommodation space.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 January 2018
Resolved
Ensure gear is not being stored on battery boxes.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 January 2018
Resolved
Ensure man overboard and firefighting drills are properly logged monthly.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 January 2018
Resolved
Resolve outstanding user fees.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 January 2017
Resolved
Replace 08 lifejackets due to excessive wear. Passenger count is reduced to 94.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 17 January 2017
Resolved
Replace stern and starboard side navigational lights. 46 CFR 183.420
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 January 2017
Resolved
Label life jacket storage. 46 CFR 185.604(f)
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 17 January 2017
Resolved
Separate child size lifejackets and label stowage. 46 CFR 180.78 (a)(5)
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 January 2017
Resolved
Vessel must have 2 portable lights at operating station. 46 CFR 183.430
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2017
Resolved
Replace hose clamp on fuel line. 46 CFR 182.410(d)
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2017
Resolved
Permanently afix fuel line with bracket. 46 CFR 182.455(b)(3)
Ownership record