MISS HADLEY

MISS HADLEY is a 2015 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2017, most recently in October 2025, along with 49 deficiencies and 1 operational control.

Records from 2017 to 2025. Most recent: inspection, 24 October 2025.

Built
2015
Last inspected
24 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1355305
Flag
UNITED STATES
Maury page id
psix-1355305

Inspections, by type

Years with a record 9 calendar years (2017–2025)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 3.8 ft
Registered tonnagegross 13 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT PONTOONS INC · TAVARES, FL, UNITED STATES · built 2015
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTri Hull
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 3 October 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
13 - Displacement, Gross Ton
13 - Simplified, Net Ton
13 - Dead Weight, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 18

24 October 2025 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8254631
29 April 2025 Administrative Inspection · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8123474
4 April 2025 Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8105092
7 January 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8059673
17 January 2024 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7850521
28 March 2023 In-Service Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7658690
6 March 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7646012
17 February 2022 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7397901
8 February 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7392719
21 October 2021 Examination of Repairs · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7337222
27 October 2020 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7070221
17 January 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6891616
6 September 2019 Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6805327
28 January 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606579
22 June 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6452621
29 January 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6345167
19 September 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6266395
10 January 2017 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6068822

Deficiency record · 49

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2025 Resolved
Suitable life jackets must be provided for all persons onboard. 20 adult life jackets were taken out of commission. Limited to 82 persons total. 46 CFR 180.71(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2025
Resolved 31 October 2025
Resolution: Provided picture of new life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2025 Resolved
Suitable life jackets must be provided for all children onboard. Two child life jackets were taken out of commission. Limited to 9 children.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2025
Resolved 31 October 2025
Resolution: Provided picture of new life jackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2025 Resolved
Fuel tank fills must be bonded to protect against static charge. Fuel tank fills were not bonded to fuel tank. 46 CFR 182.445(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2025
Resolved 21 November 2025
Resolution: Connected bonding wire.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 October 2025 Resolved
The owner or manger operator must provide servicing reports. Fire servicing records for fire extinguishers were not provided. 46 CFR 176.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2025
Resolved 31 October 2025
Resolution: Report provided.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 24 October 2025 Resolved
Each vessel must be marked as required. Vessel did not have a load mark. 46 CFR 185.602(c)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 18 November 2025
Resolution: PLaced load mark on vessel.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 April 2025 Resolved
Each vessel must comply with the Type II subdivision and damage stability requirements...(2) Carries more than 49 passengers. Due to compromised pontoon chambers in P1-P3, P9-10, and S1-S2, vessel is limited to 49 passengers until repairs are witnessed by the attending MI. 46 CFR 179.212(a)2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 31 July 2025
Resolution: All pontoon repaired, with each chamber tested with air and soap at 2 psi & found sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 4 April 2025 Resolved
Electrical equipment on a vessel must be installed to... protect the vessel from electrical hazards. Inverter is wired into a recepticle using extension cord style pigtail. remove inverter. 46 CFR 183.200
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2025
Resolved 28 April 2025
Resolution: removed from vessel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2025 Resolved
A vessel must carry an approval series 160.041 first aid kit. Vessel missing required contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2025
Resolved 13 January 2025
Resolution: Provided new first aid kit.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2025 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Improper mounting of portable fire extinguisher. Provide approved fire extinguisher mounting bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2025
Resolved 13 January 2025
Resolution: Provided new brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 January 2025 Resolved
A vessel on a rivers routes must carry three hand red flares. Vessel did not have 3 red flares. Provide 3 red flares. Vessel limited to daylight operations.
Action required: 705 - Other - as specified
Due 24 January 2025
Resolved 10 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 January 2025 Resolved
A vessel must have one or more ring life buoys as follows. Lanyard attaching waterlight to life buoy needs to be of the same material as life buoy lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2025
Resolved 13 January 2025
Resolution: Provided new waterlight line.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of...navigation rules. All-around light aft portion is extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 6 February 2024
Resolution: Light replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of...navigation rules. Stern light is not of an approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 6 February 2024
Resolution: Light replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 January 2024 Resolved
A vessel must have...at least three 9.5 liter (2 1/2) gallon buckets with an attached lanyard. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. One bucket was broken and the other two buckets were not labeled. Replace broken bucket, label all, and put lanyards on them.
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 24 January 2024
Resolution: Owner replaced with new bucket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 January 2024 Resolved
A vessel on a rivers route must carry: 3 red hand flare distress signals and 3 hand orange smoke disress signals. 1 flare and 1 orange smoke were expired. Replace with valid distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 25 January 2024
Resolution: Obtained new flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2024 Resolved
Electrical equipment exposed to the weather must be watertight. Exposed wires on overhead light near operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 25 January 2024
Resolution: Exposed wires were spliced with butt connector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2024 Resolved
Each battery must be...secured against shifting with the roll and pitch of the vessel. Two batteries wre not secured in boxes.
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 24 January 2024
Resolution: Extra batteries were removed from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2024 Resolved
A vessel must varry a first aid kit approved under approval series 160.041 or a kit with equiavlent contents and instructions. First aid kit had expired components.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 25 January 2024
Resolution: Expired items were renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 March 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. The insets observed on the STBD pontoon present an unnecessary risk to the safe operation of the vessel. Conduct pressure test of all damaged chambers to the satisfaction of the attending marine inspector and draft a repair proposal for the damaged sections.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 21 April 2023
Resolution: Satisfactory repairs and reports have been submitted. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 28 March 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Correct the following items prior to the carriage of passengers: a) Pinhole leak on top of starboard chamber 8. b) Compromised baffle between port chambers 1 & 2. c) Leaks throughout temporary repair in port chamber 3. d) Leak on outboard and inboard welds along the aft edge of port chamber 10. Vessel representative must submit repair proposals for items listed prior to any work being completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2023
Resolved 21 April 2023
Resolution: Satisfactory repairs and reports are complete. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Inspectors found 66 adult and 6 child lifejackets that were serviceable. Passengers are limited to 64 adults and 6 children until adequate lifejackets are provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2023
Resolved 9 March 2023
Resolution: O/o sent in pictures of reciept and lifejackets verifying purchase and installation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2023 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life bouy is missing retroreflective material and vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 24 March 2023
Resolution: Verified proper retroreflective material was installed on lifebuoy.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 6 March 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Terminal connections near battery switch found exposed. Install adequate protection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 24 March 2023
Resolution: Verified protection was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2023 Resolved
A vessel must carry one floating waterlight approved in accordance with § 161.010 in subchapter Q of this chapter. Battery in waterlight does not conform to manufacturer specifications. Install approved battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 24 March 2023
Resolution: O/o sent pictures of new lifebuoy verifying aqcuisition and installation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2023 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Permanently repair crack in railing on port fwd corner of vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 24 March 2023
Resolution: Verified proper repairs were made. Deficiency rectified.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 February 2022 Resolved
To maintain a valid Certificate of Inspection (COI) you must complete your annual inspection within the periods specified in 46 CFR 176.500(b)(1) and your certificate must be endorsed. The vessel did not conduct an annual inspection within the approved three month period and the current COI has not been endorsed. Vessel is not authorized to carry passengers until a COI inspection has been completed. 46 CFR 176.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2022
Resolution: Completed satisfactory inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 October 2021 Resolved
Multiple cracks found on both engine transoms. Repair welds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 22 October 2021
Resolution: Welds repaired and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 January 2020 Resolved
Each life jacket must be marked with type I retroreflective material. Identified 03 life jackets with worn retroreflective tape. Replace retroreflective tape. Passenger count is reduced by 03.
Action required: 705 - Other - as specified
Resolved 10 February 2020
Resolution: Life jackets had retroreflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2019 Resolved
An adult lifejacket must be provided for each person carried on board. 46 lifejackets were unserviceable, 08 lifejackets need new retroreflective tape. Replace/repair lifejackets. Passenger count reduced to 46.
Action required: 705 - Other - as specified
Due 11 February 2019
Resolved 30 January 2019
Resolution: All unserviceable lifejackets were replaced. Passenger count restored to 100.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 January 2019 Resolved
Ring life buoys must be fitted with retroreflective tape. Tape was missing. Install retroreflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2019
Resolved 30 January 2019
Resolution: Retroreflective tape installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 January 2019 Resolved
Nonmetallic hose must comply with SAE J-1475. Starboard fuel tank had one clamp that was corroded and loose. Provide functional double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2019
Resolved 30 January 2019
Resolution: Hose clamp installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 January 2019 Resolved
Three 2.5-gallon fire buckets are required. Vessel has three 2-gallon buckets. Replace with 2.5-gallon buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2019
Resolved 30 January 2019
Resolution: Three 2.5 gallon buckets were provided, labeled, and with lanyards.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 January 2018 Resolved
07 adult lifejackets missing vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2018
Resolved 29 January 2018
Resolution: Company rep marked all jackets with vessel name.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 January 2018 Resolved
4 adult lifejackets and 4 child lifejackets missing retro. 4 child lifejackets were in excess of minimum required (11). Passenger count reduced from 100 to 96 until adult lifejacket def is resolved.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2018
Resolved 2 February 2018
Resolution: Retro tape was applied IAW 46 CFR 185.604(h).
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 January 2018 Resolved
Water light found not to be operational. Vessel restricted to daytime ops until proper operation is demonstrated.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 2 February 2018
Resolution: Battery was replaced and op test of the light was satisfactory.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 29 January 2018 Resolved
Fire extinguisher at bow missing tamper seal. Service extinguisher as required.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 2 February 2018
Resolution: Cintas provided vessel with new fire extinguisher, tamper seal was intact.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 January 2018 Resolved
All three fire extinguishers improperly secured to mounting brackets.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 2 February 2018
Resolution: All extinguishers have been properly secured to their brackets.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 January 2018 Resolved
Two portable battery flashlights are required. Only one onboard, which was not functional. Provide two functioning lights.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 2 February 2018
Resolution: Two flashlights are onboard.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 January 2018 Resolved
Permanently affix overhead light at fwd end of accommodation space.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 2 February 2018
Resolution: The light fixture has been replaced with a permanently attached fixture.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 January 2018 Resolved
Ensure gear is not being stored on battery boxes.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 2 February 2018
Resolution: The gear was removed from the vicinity of the battery boxes.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 January 2018 Resolved
Ensure man overboard and firefighting drills are properly logged monthly.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 29 January 2018
Resolution: Vessel master agreed to begin logging drills.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 January 2018 Resolved
Resolve outstanding user fees.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 12 February 2018
Resolution: Outstanding user fees were paid. MISLE shows no outstanding user fees.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 January 2017 Resolved
Replace 08 lifejackets due to excessive wear. Passenger count is reduced to 94.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 25 January 2017
Resolution: 08 Lifejackets were replaced.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 17 January 2017 Resolved
Replace stern and starboard side navigational lights. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 25 January 2017
Resolution: Navigational lights were replaced and secured properly.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 January 2017 Resolved
Label life jacket storage. 46 CFR 185.604(f)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 25 January 2017
Resolution: Life jacket stowage was properly labeled.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 17 January 2017 Resolved
Separate child size lifejackets and label stowage. 46 CFR 180.78 (a)(5)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 25 January 2017
Resolution: Child life jackets were separated and benches for storage were marked.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 January 2017 Resolved
Vessel must have 2 portable lights at operating station. 46 CFR 183.430
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 January 2017
Resolution: Owner purchased 2 flash lights.
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2017 Resolved
Replace hose clamp on fuel line. 46 CFR 182.410(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 25 January 2017
Resolution: Hose clamp was replaced and secured.
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2017 Resolved
Permanently afix fuel line with bracket. 46 CFR 182.455(b)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 25 January 2017
Resolution: Fuel line was secured with bracket.