MAURY USCG vessel records
← All vessels

TWO HARBORS

Built
2015
Last inspected
18 March 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 18 March 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2015–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1356300
Flag
UNITED STATES
Maury page id
psix-1356300

Documentation record

Registered dimensions (L × B × D)134.4 ft × 39.9 ft × 8.9 ft
Registered tonnagegross 349 / net 104
ITC dimensions (L × B × D)134.4 ft × 39.9 ft × 8.9 ft
ITC tonnagegross 349 / net 104
BuilderCONRAD SHIPYARD LLC · AMELIA, LA, UNITED STATES · built 2015
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 2 October 2025 · expires 31 October 2026
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it349 - Convention (Subpart B), Gross Ton
104 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 25 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LUCY FRANCO Towing Vessel · MISLE 205625 · 21 January 2020 · activity 6894253

Inspection history · 25

18 March 2025 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8067059
25 September 2024 Annual Inspection · Excursion Permit · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7990607
13 September 2024 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7990405
15 September 2023 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7775159
15 August 2023 Internal Structural Exam · Deficiency Check · Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7738617
13 June 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7713771
16 September 2022 Annual Inspection · Excursion Permit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7548288
29 April 2022 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7438709
5 October 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7324113
10 September 2021 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7307518
21 September 2020 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7058114
31 August 2020 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7046912
20 August 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7038723
21 January 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6894253
13 September 2019 Excursion Permit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6774962
18 May 2019 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6703310
10 May 2019 In-Service Inspection · Excursion Permit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6674710
2 October 2018 Annual Inspection · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6543610
18 September 2018 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6540805
11 June 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6441324
15 May 2018 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6411500
18 September 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6261345
17 March 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6106693
8 December 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6052704
7 August 2015 Initial Certification · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5208791

Deficiency record · 3

03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 September 2024 Resolved
Means for securing weathertightness. (1) The means for securing and maintaining weathertightness shall be to the satisfaction of the assigning authority. The two midship hatches opposite side of barge from loading ramp missing gasket seals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 22 October 2024
Resolution: New hatches installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 September 2024 Resolved
Manholes and flush scuttles... shall be closed by substantial covers capable of being made watertight. Unless secured by closely spaced bolts, the covers shall be permanently attached. Captive Chains missing and/or unattached on two forward midship deck hatches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 22 October 2024
Resolution: Captive chains installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2023 Resolved
All electrical engineering details and installations shall be designed and installed in accordance with subchapter J (Electrical Engineering) of this chapter. Each panel board must meet Section 9.10.1 of IEEE 45.1 Electrical panel board in generator space is missing required dead front cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2023
Resolved 21 August 2023
Resolution: Photo was provided for installing missing dead front cover.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.