MAURY USCG vessel records
← All vessels

KAPRIJKE

KAPRIJKE is a 2015 tank ship. The Coast Guard has recorded 26 inspections since 2016, most recently in November 2025, along with 9 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 28 November 2025.

Built
2015
Last inspected
28 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9687485
1356805
Flag
BELGIUM
Maury page id
psix-1356805

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (2016–2025)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it7785 - Convention (Subpart B), Net Ton
29639 - Dead Weight, Metric Ton
41489 - Displacement, Metric Ton
25952 - Regulatory (Subpart C or D), Gross Ton
7785 - Regulatory (Subpart C or D), Net Ton
25952 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 26

28 November 2025 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8274851
19 August 2025 COC-GAS Renew · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8211279
13 October 2024 PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8017259
3 October 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7802694
19 September 2023 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7794888
10 December 2022 Ballast Water Examination · COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7604364
25 March 2022 PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7415624
25 September 2021 PSC B · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7315712
29 January 2021 PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7126735
4 June 2020 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6968168
2 June 2020 COC-GAS Renew · PSC B · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6966505
27 April 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6671441
23 April 2019 COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6667387
14 May 2018 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6414222
17 April 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6393069
5 March 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6099120
4 February 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6082705
20 January 2017 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6073937
7 December 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6053802
25 November 2016 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6046747
2 November 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6034010
1 November 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033395
9 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5902212
19 May 2016 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5878913
30 April 2016 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5866480
15 February 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5815262

Deficiency record · 9

12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 19 August 2025 Resolved
75 SOLAS (14) VII/13.1 IGC (93) 10.2.1 A gas carrier shall comply with the requirements of the International Gas Carrier Code. Intrinsically safe electrical equipment and wiring may be fitted in all Gas-dangerous spaces and zones. PSCO observed failed cable glands installed on the following equipment: #1 Compressor condensate valve actuator #2 STBD pump motor #2 STBD High level/Overfill gland #2 compressor junction box #3 compressor start/stop button #3 compressor junction box cable gland #3 receiver outlet temperature sensor Gas free start/stop buttons Yellow light fixture on FWD side of compressor room High level alarm forward mast riser Deck tank high level/overfill
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2025
Resolved 1 September 2025
Resolution: Received class report attesting to the correction of deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 August 2025 Resolved
74SOLAS(14) II-l/3.1 Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. PSCO observed that the port compressor room water tight door was not sealing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2025
Resolved 1 September 2025
Resolution: Received class report attesting to the correction of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 August 2025 Resolved
74SOLAS(14)III/31.1.1.1 LSA 4.4.6.5 Cargo ships shall carry: One or more totally enclosed lifeboats complying with the requirements of section 4.6 of the code. Provisions shall be made for ahead and astern propulsion. PSCO observed that upon initial testing, the STBD lifeboat would not engage in astern propulsion.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 August 2025
Resolved 19 August 2025
Resolution: Crew was able to adjust the throttle switch that was preventing astern propulsion to be engaged.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 September 2023 Resolved
Provision shall be made for marking each life raft with the name and port of registry of the ship to which it is to be fitted, in such a form that the ship identification can be changed at anytime without opening the container. 3 out of 5 liferafts on board cards were incorrect locations and mislabeled. Liferaft case serial number 5086110215518 on the starboard side's card serial number and capacity was blank.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 October 2023
Resolution: Vessel provided documentation indicating correction
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 September 2023 Resolved
An airlock should only be permitted between a gas-dangerous zone on the open weather deck and a gas-safe space and should consist of the two steel doors substantially gastight. PSCO observed gaps in hatch heading to cargo deck, making space not gastight.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 3 October 2023
Resolution: Vessel provided documentation indicating correction
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 19 September 2023 Resolved
The fire-fighter's outfits or sets of personal equipment shall be kept ready for use in an easily accessible location. Fireman's fire control room: Observed fully outfitted fire team with SCBA bottles in close contact with ventilation distribution panel contact switches.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 October 2023
Resolution: Vessel provided documentation indicating new stowage arrangement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 April 2019 Resolved
06199- A GAS CARRIER SHALL COMPLY WITH THE REQUIREMENTS OF THE INTL GAS CARRIER CODE. THE CONDITION OF THE SHIP AND EQUIPMENT SHOULD BE MAINTAINED TO CONFORM WITH THE CODE TO ENSURE THE SHIP WILL REMAIN WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED 11 PPM AMMONIA ON MARINE CHEMIST CERTIFICATE FOR COMPRESSOR ROOM. WHEN [name withheld] THERE WAS A STRONG AMMONIA ODOR.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 April 2019
Resolution: SEC HOU-GAL received satisfactory documentation from LLOYD'S attesting to the resolution of open deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 17 April 2018 Resolved
1870-Special Requirements-Emergency shut down valves in liquid piping should fully close under all service conditions within 30 seconds of actuation. PSCO observed emergency shutdown valves did not close in 30 seconds. 74 SOLAS (14)VII/13.1, IGC 93/5.6.4.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 April 2018
Resolution: Valves adjusted and closed within the required time.
Construction/Loadline › Markings › Load Line Mark
Issued 17 April 2018 Resolved
1220-Load lines-The rings, lines and letters shall be painted in white or yellow on dark background. Starboard load line paint has faded to same color as hull. ICLL 66, ANNEX1/Reg. 8.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 May 2018
Resolved 14 May 2018
Resolution: Vessel provided picture of freshly painted load lines.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.