Records from 2001 to 2008. Most recent: inspection, 10 December 2008.
Documentation record
Tonnage as PSIX records it318 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
95 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
10 December 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3392889
13 September 2007
Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3056814
27 April 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2941191
11 April 2007
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2906273
10 November 2005
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2527854
23 September 2004
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2213836
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973264
23 October 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1934264
19 November 2002
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1707348
1 October 2002
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1682533
11 January 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1477736
19 September 2001
Type not recorded
No type recorded · USCGC DAUNTLESS (WMEC 624) · Activity 1523816
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 December 2008
Resolved
EPIRB was not recorded as being tested on a monthly basis.
Due 10 January 2009
Resolved 29 October 2009
Resolution: EPIRB checks logged
Operations/Management › Drills/Instruction › Abandon Ship
Issued 10 December 2008
Resolved
Logs were not kept up on for drills being conducted. Should be inspected next top side for compliance.
Due 12 January 2009
Resolved 29 October 2009
Resolution: Logs and drills conducted and logged
Lifesaving › Lifejacket/PFD (Type IV) › Retroreflective Material
Issued 10 December 2008
Resolved
Install new reflective tape on life rings
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2008
Resolved 11 December 2008
Communications › Public Address System › Amplifier
Issued 10 December 2008
Resolved
Install PA on Emergency source of power
Due 12 January 2009
Resolved 11 December 2008
Navigation › Piloting/Steering
Issued 1 October 2002
Resolved
PROVIDE VISUAL INDICATOR FOR STEERING MOTOR OPERATION AT PILOTHOUSE CONTROL STATION AS PER 46 CFR 182.610 (g) (1).
Action required: 705 - Other - as specified
Due 17 November 2002
Resolved 19 November 2002
Resolution: Visual Indicators provided in pilothouse.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 1 October 2002
Resolved
PROVIDE AUTOMATIC SHUTDOWN FOR BOW THRUSTER PRIME MOVER LOCATED IN ENGINEROOM PROTECTED BY FIXED CO2 SYSTEM AS PER 46 CFR 181.410 (B) (10).
Action required: 705 - Other - as specified
Due 17 November 2002
Resolved 19 November 2002
Resolution: Auto shut down of bow thruster prime mover provided.
Documentation › Certificates/Documents
Issued 11 January 2002
Resolved
FCC RAIDO LICINSE NOT PROVIDE FOR ALL PERSONNEL OPERATING MARINE RADIOS. LEGACY COMPONENT DESC: FCC LICENSE
Due 15 January 2002
Resolved 15 January 2002
Documentation › Manuals/Policy Documentation
Issued 11 January 2002
Resolved
CURRENT COPIES OF COAST PILOT AND LIGHT LIST NOT PROVIDED. LEGACY COMPONENT DESC: COAST PILOT, LIGHT LIST.
Condition: Unknown
Due 15 January 2002
Resolved 15 January 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 11 January 2002
Resolved
PORT MAIN ENGINE ALARMS NOT WORKING AT PILOT HOUSE. LEGACY COMPONENT DESC: ALARMS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 11 January 2002